ISO 23316-6:2024 PDF
Tractors and machinery for agriculture and forestry — Electrical high-power interface 700 V DC / 480 V AC — Part 6: Communication signals
Tractors and machinery for agriculture and forestry — Electrical high-power interface 700 V DC / 480 V AC — Part 6: Communication signals
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 94
- Дата публикации:
- 12 января 2024 г.
- Издание:
- ISO IS 23316 edition 1 version 1
- ICS:
- 65.060.10
This document specifies the communication interface, so that the transmitted parameters, signals and objects between a supply system (SS), with power converter/switch (PC/S) and high power interface – master control (HPI-MC) including the tractor implement management (TIM) server, and a consumer system (CS), with application (APP) and high power interface – control (HPI-C) including the TIM client and the task controller, can be used is in the agricultural industry. The mentioned signals are used during identification, initialization, operation, and shutdown modes of operation. This document does not cover the definitions of suspect parameter numbers (SPNs) for the signals, within the parameter group numbers (PGNs) for messages and the message setup. These definitions are given in ISO 11783 and SAE J1939. NOTE For information on messages (PGNs) see also Annex B.
Abstract
Overview
ISO 23316-6:2024 defines the communication signals for the electrical high‑power interface (HPI) used in modern agricultural and forestry machinery operating at 700 V DC / 480 V AC. It specifies how parameters, signals and objects are exchanged between a supply system (SS) - including the power converter/switch and HPI‑master control (HPI‑MC) with a TIM (Tractor‑Implement Management) server - and a consumer system (CS) - including application (APP) and HPI‑control (HPI‑C) with a TIM client and task controller. The document covers communication needed during identification, initialization, normal operation and shutdown.
Key topics and technical requirements
- Communication process & system handshake: defined phases, preconditions and monitoring required to safely establish and maintain HPI connections.
- System topologies: overview of AC and DC system topologies and how they affect communication.
- Fieldbus‑based and IL‑based systems: identification, initialization and normal operation sequences for both fieldbus (e.g., ISOBUS) and isolation‑link (IL) implementations.
- HPI interlock function: functional requirements and principles for interlock signalling to protect equipment and personnel.
- Connection status & TIM interaction: requirements for HPI connection status monitoring and interaction with the TIM function state machine.
- Insulation monitoring & isolation resistance: communication procedures for insulation monitoring (OIM) and minimum isolation resistance checks during initialization and online operation.
- Diagnostics & annexes: includes normative communication signal listings (Annex A), ISOBUS message guidance (Annex B), topology examples, diagnostic trouble codes (DTCs) and insulation monitoring examples.
Note: ISO 23316‑6 does not define SPNs/PGNs or message parameter numbers - these are provided by ISO 11783 and SAE J1939.
Applications and who uses it
- Tractor and implement manufacturers: design interoperable high‑power electrical interfaces and TIM implementations.
- Power converter and HPI suppliers: ensure compatible signalling, handshake logic and interlocks.
- System integrators and OEMs: implement safe startup/shutdown and communication sequences for electrified implements.
- Testing labs & certification bodies: verify compliance with handshake, insulation monitoring and fieldbus sequences.
- Standards and safety engineers: align electrical, mechanical and communication requirements across the ISO 23316 series.
Related standards
- ISO 23316 (Parts 1–7) - series for high‑power interfaces
- ISO 11783 (ISOBUS) - message/PGN/SPN definitions and application layer
- SAE J1939 - heavy‑duty vehicle network messaging
- ISO 16230‑1, ISO 23316‑1/2/4/5/7, IEC 60204 - normative references used by ISO 23316‑6
Keywords: ISO 23316‑6, electrical high‑power interface, 700 V DC, 480 V AC, communication signals, HPI‑MC, HPI‑C, TIM, ISOBUS, insulation monitoring, agricultural machinery.
Технические детали
- Технический комитет
- ISO/TC 23/SC 19 - Agricultural electronics
- SKU
- ISO 23316-6:2024
Похожие стандарты
Стандарты, упомянутые в описании
BS ISO 11783-12:2019
ДействующийTractors and machinery for agriculture and forestry. Serial control and communications data network. Diagnost…
BS ISO 23316-5:2023
ДействующийTractors and machinery for agriculture and forestry. Electrical high-power interface 700 V DC / 480 V AC. DC…
SIST EN ISO 16230-1:2015
ДействующийAgricultural machinery and tractors - Safety of higher voltage electrical and electronic components and syste…
Overview EN ISO 16230-1:2015 (ISO 16230-1:2015) - published by CEN - sets general safety requirements for higher-voltage electrical and electronic components and systems on agricultural machinery and…
IEC 60204-32:2008
ДействующийSafety of machinery - Electrical equipment of machines - Part 32: Requirements for hoisting machines
IEC 60204-32:2008 Overview IEC 60204-32:2008 is an international standard developed by the International Electrotechnical Commission (IEC) that sets essential safety requirements for the electrical e…