ISO 23734:2021 PDF
Marine technology — Marine environment impact assessment (MEIA) — On-board bioassay to monitor seawater quality using delayed fluorescence of microalga
Marine technology — Marine environment impact assessment (MEIA) — On-board bioassay to monitor seawater quality using delayed fluorescence of microalga
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 17
- Дата публикации:
- 27 июля 2021 г.
- Издание:
- ISO IS 23734 edition 1 version 1
- ICS:
- 13.020.30
This document specifies a bioassay for the determination of the presence of unknown toxic contaminants in test seawater (see Figure A.1). It is based on the inhibition of photosynthetic activity of the marine cyanobacterium Cyanobium sp. (NIES-981) by such toxic contaminants. The inhibition is determined based on delayed fluorescence (DF) intensity. The method is rapid and requires less laboratory space than standard bioassays. Hence, it can be used on-board to generate basic data for seawater quality management at deep-sea mining sites where time and space are extremely limited.
Abstract
Overview
ISO 23734:2021 - Marine technology - Marine environment impact assessment (MEIA) - specifies an on‑board bioassay to monitor seawater quality by measuring the delayed fluorescence (DF) of the marine cyanobacterium Cyanobium sp. (NIES‑981). The method detects the presence of unknown toxic contaminants through inhibition of photosynthetic activity. It is designed for rapid, space‑efficient use on vessels or platforms (e.g., deep‑sea mining sites) where conventional laboratory resources are limited.
Key topics and technical requirements
- Test principle: Toxicants inhibit photosynthetic electron transport; inhibition is quantified via DF intensity and DF decay curves after transferring cells from light to darkness (DF signals occur over milliseconds to minutes).
- Test organism: Cyanobium sp. (NIES‑981) supplied as an algal stock culture (living or cryopreserved).
- Test medium: Growth medium (ASW‑SN) mixed with test seawater; a typical dilution used is test seawater : growth medium = 80 : 20 (v/v).
- Procedure highlights:
- Prepare algal inoculum from land‑prepared stock cultures.
- Set up control and test tubes (duplicate cultures in triplicate recommended).
- Incubate for 24 h on‑board, then measure DF.
- Compare test vs control using statistical tests; optionally determine ECx, NOEC, LOEC via serial dilutions.
- Apparatus & reagents: high‑sensitivity luminometer for DF, incubator/tube shaker, culture tubes, clean bench, reagents for growth medium (nutrients, trace metals, tris), and instruments for cell density measurement.
- Data interpretation: Plot DF decay curves, calculate percent inhibition, and assess significance to indicate contamination.
- Annexes: include schematic procedures, medium preparation, cryopreservation guidance, and reference check data.
Practical applications
- Rapid on‑site screening for seawater contamination at deep‑sea mining operations, discharge points, and other marine works.
- Early warning tool to support environmental safety actions, minimize spread of pollutants, and reduce operational downtime.
- Useful where onboard space, time, and specialist analytical instrumentation (e.g., ICP‑MS) are not available.
- Detects a broad spectrum of toxicants (including unknown contaminants), though it does not identify specific chemical species.
Who should use this standard
- Marine environmental scientists and technicians conducting shipboard monitoring
- Deep‑sea mining operators and environmental managers
- Regulatory bodies, environmental consultants, and research institutions performing MEIA
- Organizations needing rapid, on‑site toxicity screening for seawater quality management
Related standards and guidance
- ISO 10253 (general algal bioassay standards) - for extended laboratory protocols and comparisons
- International Seabed Authority (ISA) guidance on environmental impact assessment for seabed activities
Keywords: ISO 23734:2021, on‑board bioassay, delayed fluorescence, Cyanobium sp., seawater quality, marine environment impact assessment, deep‑sea mining, DF luminometer.
Технические детали
- Технический комитет
- ISO/TC 8/SC 13 - Marine technology
- SKU
- ISO 23734:2021
Похожие стандарты
Упомянутые в описании и другие стандарты ISO
SIST EN ISO 10253:2024
ДействующийWater quality - Marine algal growth inhibition test with Skeletonema sp. and Phaeodactylum tricornutum (ISO 1…
Overview EN ISO 10253:2024 - Water quality - Marine algal growth inhibition test with Skeletonema sp. and Phaeodactylum tricornutum - is a CEN-adopted International Standard that specifies a laborato…
ISO 8689-1:2000
ДействующийWater quality — Biological classification of rivers — Part 1: Guidance on the interpretation of biological qu…
Overview ISO 8689-1:2000, titled Water quality - Biological classification of rivers - Part 1: Guidance on the interpretation of biological quality data from surveys of benthic macroinvertebrates, is…
ISO/ASTM51540-04(2012)
ОтменёнStandard Practice for Use of a Radiochromic Liquid Dosimetry System (Withdrawn 2020)
Significance and Use4.1 The radiochromic liquid dosimetry system provides a means of measuring absorbed dose in materials (5-7). Under the influence of ionizing radiation, chemical reactions take pla…
ISO/ASTM51204-04
ДействующийStandard Practice for Dosimetry in Gamma Irradiation Facilities for Food Processing (Withdrawn 2013)
Significance and Use4.1 Food products may be treated with ionizing radiation, such as gamma-rays from 60Co or 137Cs sources, for numerous purposes, including control of parasites and pathogenic micro…
ISO/ASTM51431-05
ОтменёнStandard Practice for Dosimetry in Electron Beam and X-Ray (Bremsstrahlung) Irradiation Facilities for Food P…
Significance and Use4.1 Food products may be treated with acceleratorgenerated radiation (electrons and X-rays) for numerous purposes, including control of parasites and pathogenic microorganisms, in…
ISO/ASTM52628-20e1
ДействующийStandard Practice for Dosimetry in Radiation Processing
1.1 This practice describes the basic requirements that apply when making absorbed dose measurements in accordance with the ASTM E61 series of dosimetry standards. In addition, it provides guidance o…
ISO/ASTM52921-13(2019)
ДействующийStandard Terminology for Additive Manufacturing—Coordinate Systems and Test Methodologies
Significance and Use 3.1 Although many additive manufacturing systems are based heavily upon the principles of Computer Numerical Control (CNC), the coordinate systems and nomenclature specific to CN…
ISO/ASTMTR52917-EB
ДействующийAdditive Manufacturing — Round Robin Testing — General Guidelines
This document outlines the steps with regard to aspects of design to conduct and run a round robin study (RRS) to assess the degree of variability in an additive manufacturing material or process. Th…