ISO 24157:2008 specifies standardized methods for reporting aberrations of the human eye.
Abstract
Overview
ISO 24157:2008 - Ophthalmic optics and instruments: Reporting aberrations of the human eye - specifies standardized methods for reporting optical aberrations of the human eye. The standard defines coordinate and sign conventions, formal representations of wavefront data, and documentation formats to ensure consistent, reproducible reporting across clinical, research and manufacturing contexts.
Key Topics
- Scope and purpose
- Standardizes how to report aberrations of the human eye (wavefront error, OPD, RMS).
- Coordinate system
- Uses the standard ophthalmic coordinate system per ISO 8429: x = local horizontal, y = local vertical, z = line of sight; pupil centre as origin and defined sign conventions.
- Wavefront definitions
- Defines wavefront error (W(x,y)), optical path-length difference (OPD) and wavefront gradient; units in metres (typically micrometres).
- Representation methods
- Primary method: expansion as sums of Zernike polynomial functions and associated Zernike coefficients (normalized and un‑normalized).
- Alternative representations: wavefront gradient fields or direct wavefront error function values and topographical maps.
- Data presentation
- Rules for presenting normalized Zernike coefficients, magnitude/axis forms, topographic maps, and pooled population data.
- Requirement that each coefficient set be accompanied by the aperture diameter used to generate it.
- Quality metrics
- Definition and computation of RMS wavefront error (excluding piston and average tilt).
- Guidance on gradient fit error when fitting slopes to Zernike terms.
- Informative annexes
- Methods to generate Zernike coefficients from slope data, conversion procedures for differing aperture sizes, decentration and rotation, notation conversion, and tables/algorithms (including normalized Zernike polynomials through 6th radial order).
Applications and Users
ISO 24157:2008 is intended for:
- Clinical researchers studying ocular aberrations and vision quality.
- Eye care professionals and optometrists documenting higher‑order aberrations.
- Medical device manufacturers of aberrometers, wavefront sensors and refractive surgical planning tools.
- Optical laboratories producing custom optical corrections (e.g., scleral lenses, customized contact lenses). Practical benefits include consistent reporting for device validation, cross‑study comparison, regulatory submissions, and improved communication between clinicians, researchers and manufacturers.
Related Standards
- ISO 8429 (Ophthalmic coordinate system and graduated dial scales) - referenced for coordinate conventions.
- Informative annexes in ISO 24157 itself provide conversion and algorithm guidance for interoperability.
Keywords: ISO 24157:2008, ophthalmic optics, reporting aberrations, Zernike coefficients, wavefront error, RMS wavefront error, wavefront gradient, aberrometry.
Технические детали
- Технический комитет
- ISO/TC 172/SC 7 - Ophthalmic optics and instruments
- SKU
- ISO 24157:2008
Похожие стандарты
Упомянутые в описании и другие стандарты ISO
SIST EN ISO 8429:2000
ДействующийOptics and optical instruments - Ophthalmology - Graduated dial scale (ISO 8429:1986)
Overview EN ISO 8429:1996 (ISO 8429:1986) specifies the geometry and conventions for a graduated dial scale used in ophthalmic optics and optical instruments. The standard defines a consistent angula…
ISO 24157:2008/Amd 1:2020
ДействующийOphthalmic optics and instruments — Reporting aberrations of the human eye — Amendment 1
Overview ISO 24157:2008/Amd 1:2020 is an internationally recognized amendment to the ISO 24157:2008 standard, developed by the International Organization for Standardization (ISO). This amendment spe…
ISO 8689-1:2000
ДействующийWater quality — Biological classification of rivers — Part 1: Guidance on the interpretation of biological qu…
Overview ISO 8689-1:2000, titled Water quality - Biological classification of rivers - Part 1: Guidance on the interpretation of biological quality data from surveys of benthic macroinvertebrates, is…
ISO/ASTM51540-04(2012)
ОтменёнStandard Practice for Use of a Radiochromic Liquid Dosimetry System (Withdrawn 2020)
Significance and Use4.1 The radiochromic liquid dosimetry system provides a means of measuring absorbed dose in materials (5-7). Under the influence of ionizing radiation, chemical reactions take pla…
ISO/ASTM51204-04
ДействующийStandard Practice for Dosimetry in Gamma Irradiation Facilities for Food Processing (Withdrawn 2013)
Significance and Use4.1 Food products may be treated with ionizing radiation, such as gamma-rays from 60Co or 137Cs sources, for numerous purposes, including control of parasites and pathogenic micro…
ISO/ASTM51431-05
ОтменёнStandard Practice for Dosimetry in Electron Beam and X-Ray (Bremsstrahlung) Irradiation Facilities for Food P…
Significance and Use4.1 Food products may be treated with acceleratorgenerated radiation (electrons and X-rays) for numerous purposes, including control of parasites and pathogenic microorganisms, in…
ISO/ASTM52628-20e1
ДействующийStandard Practice for Dosimetry in Radiation Processing
1.1 This practice describes the basic requirements that apply when making absorbed dose measurements in accordance with the ASTM E61 series of dosimetry standards. In addition, it provides guidance o…
ISO/ASTM52921-13(2019)
ДействующийStandard Terminology for Additive Manufacturing—Coordinate Systems and Test Methodologies
Significance and Use 3.1 Although many additive manufacturing systems are based heavily upon the principles of Computer Numerical Control (CNC), the coordinate systems and nomenclature specific to CN…