ISO 24340:2006 PDF
Resilient floor coverings — Determination of thickness of layers
Resilient floor coverings — Determination of thickness of layers
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 4
- Дата публикации:
- 10 марта 2006 г.
- Издание:
- ISO IS 24340 edition 1 version 1
- ICS:
- 97.150
ISO 24340:2006 describes a method for determining the thickness of different layers of resilient floor coverings.
Abstract
Overview
ISO 24340:2006 specifies a laboratory method for determining the thickness of layers in resilient floor coverings using direct optical measurement. The standard defines sampling, specimen preparation, instrumentation, measurement procedure, calculation and reporting requirements to ensure consistent, repeatable layer-thickness results for sheet and tile products.
Key topics and technical requirements
- Principle: thickness measured directly by optical means (microscope or video microscope).
- Apparatus:
- Microscope/video microscope with magnification of at least 40× and a micrometric scale or adjustable screen lines.
- Two accuracy classes: eyepiece scale readable to 0.01 mm, or for thin layers an eyepiece readable to 0.0025 mm (for thicknesses below 0.05 mm).
- Stage micrometer for calibration, lamp/light source, specimen holder, sharp blade and straightedge.
- Sampling & specimens:
- Sheet coverings: five specimens (10 mm × 25 mm) evenly distributed across the width.
- Tiles: one specimen (10 mm × 25 mm) from each of five separate tiles from the pack.
- Conditioning: specimens conditioned a minimum of 24 h at (23 ± 2) °C and (50 ± 5) % RH; test in same environment.
- Test procedure:
- Cut specimens face down on a suitable board to ensure a clean edge.
- Mount with the cut surface perpendicular to the optical axis.
- Calibrate eyepiece against stage micrometer and record calibration factor.
- Focus so both layer edges are sharp; take three readings per specimen at least 10 mm apart.
- Reporting & results:
- Calculate mean thickness per layer; report to nearest 0.01 mm or 0.0025 mm depending on instrument.
- Test report must identify samples, previous history, deviations, mean/min/max readings, and a statement of conformity with ISO 24340:2006.
Applications and who uses it
ISO 24340:2006 is used for quality control, product specification, compliance testing and material research by:
- Flooring manufacturers verifying layer structure and wear-layer thickness.
- Independent testing laboratories performing standardized optical thickness measurements.
- Specifiers, procurement officers and inspectors checking product conformity to stated construction.
- R&D teams assessing multilayer constructions and comparative product performance.
Keywords: ISO 24340:2006, resilient floor coverings, thickness of layers, optical measurement, microscope, wear layer thickness, sampling, conditioning, test procedure.
Related standards
- EN 429 - Resilient floor coverings - Determination of the thickness of layers.
- ASTM F410 - Standard test method for wear layer thickness of resilient floor coverings by optical measurement.
Технические детали
- Технический комитет
- ISO/TC 219 - Floor coverings
- SKU
- ISO 24340:2006
Похожие стандарты
Другие стандарты ISO
ISO 8689-1:2000
ДействующийWater quality — Biological classification of rivers — Part 1: Guidance on the interpretation of biological qu…
Overview ISO 8689-1:2000, titled Water quality - Biological classification of rivers - Part 1: Guidance on the interpretation of biological quality data from surveys of benthic macroinvertebrates, is…
ISO/ASTM51540-04(2012)
ОтменёнStandard Practice for Use of a Radiochromic Liquid Dosimetry System (Withdrawn 2020)
Significance and Use4.1 The radiochromic liquid dosimetry system provides a means of measuring absorbed dose in materials (5-7). Under the influence of ionizing radiation, chemical reactions take pla…
ISO/ASTM51204-04
ДействующийStandard Practice for Dosimetry in Gamma Irradiation Facilities for Food Processing (Withdrawn 2013)
Significance and Use4.1 Food products may be treated with ionizing radiation, such as gamma-rays from 60Co or 137Cs sources, for numerous purposes, including control of parasites and pathogenic micro…
ISO/ASTM51431-05
ОтменёнStandard Practice for Dosimetry in Electron Beam and X-Ray (Bremsstrahlung) Irradiation Facilities for Food P…
Significance and Use4.1 Food products may be treated with acceleratorgenerated radiation (electrons and X-rays) for numerous purposes, including control of parasites and pathogenic microorganisms, in…
ISO/ASTM52628-20e1
ДействующийStandard Practice for Dosimetry in Radiation Processing
1.1 This practice describes the basic requirements that apply when making absorbed dose measurements in accordance with the ASTM E61 series of dosimetry standards. In addition, it provides guidance o…
ISO/ASTM52921-13(2019)
ДействующийStandard Terminology for Additive Manufacturing—Coordinate Systems and Test Methodologies
Significance and Use 3.1 Although many additive manufacturing systems are based heavily upon the principles of Computer Numerical Control (CNC), the coordinate systems and nomenclature specific to CN…
ISO/ASTMTR52917-EB
ДействующийAdditive Manufacturing — Round Robin Testing — General Guidelines
This document outlines the steps with regard to aspects of design to conduct and run a round robin study (RRS) to assess the degree of variability in an additive manufacturing material or process. Th…
ISO/ASTM52901-17(2023)
ДействующийStandard Guide for Additive Manufacturing – General Principles – Requirements for Purchased AM Parts
Scope 1.1 This document defines and specifies requirements for purchased parts made by additive manufacturing. 1.2 It gives guidelines for the elements to be exchanged between the customer and the pa…