ISO 24465:2023 PDF
Surface chemical analysis — Determination of the minimum detectability of surface plasmon resonance device
Surface chemical analysis — Determination of the minimum detectability of surface plasmon resonance device
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 9
- Дата публикации:
- 10 января 2023 г.
- Издание:
- ISO IS 24465 edition 1 version 1
- ICS:
- 71.040.40
This document describes a method for determining the minimum detectability of surface plasmon resonance device. This document is applicable to surface plasmon resonance devices of the white-light illumination type and the laser illumination type with the angle scanning capability.
Abstract
Overview
ISO 24465:2023 specifies a standardized method to determine the minimum detectability (limit of detection) of surface plasmon resonance (SPR) devices. Applicable to both white‑light illumination and laser illumination SPR systems with angle‑scanning capability, the standard defines sample preparation, instrument conditions, data acquisition and a statistical protocol to quantify the lowest reliably measurable response.
Key topics and requirements
- Scope: Method for measuring the lowest detectable SPR signal for white‑light and laser angle‑scanning devices (Kretschmann geometry).
- Measurement principle: Monitor changes in reflected light (spectral dip or resonant angle) caused by analyte‑induced changes in dielectric constant; responses recorded as a sensorgram (response units, RU) using CCD or photodetectors.
- Statistical approach: Uses the 3‑sigma rule to define the lower limit of detectability (signal-to-noise ≈ 1); series measurements across concentrations yield SD and detection limit.
- Standard sample: Recommends single neutral solutes (e.g., ethylene glycol or sucrose in DI water) to avoid complex surface chemistry; prepare multiple concentration points (minimum five) for statistical accuracy.
- Instrument conditions: Control and document optics alignment, cleanness of optics, temperature, and flow rate (typical suggested range 5 μl/min to 100 μl/min).
- Sensor chip: Use a bare metal (gold) sensor chip for absolute device characterization; typical gold film thickness is around 100 nm.
- Data recording: Detailed acquisition and recording procedures are specified to ensure reproducible RU measurements and derivation of the limit of detection.
Applications and practical value
- Characterizing and validating the sensitivity performance of SPR instruments during manufacturing, acceptance testing, or routine quality control.
- Establishing traceable limit of detection (LOD) for research labs performing label‑free biomolecular binding studies.
- Supporting procurement decisions and performance comparisons between SPR platforms (white‑light vs. laser systems).
- Providing non‑expert operators with a simple, reproducible protocol using neutral analytes for baseline device capability assessment.
Who should use this standard
- SPR instrument manufacturers and calibration labs
- Analytical chemists and surface scientists
- QA/QC personnel in biotechnology and pharmaceuticals
- Research groups deploying label‑free biosensing or surface chemical analysis
Related guidance
- Prepared by ISO/TC 201 (Surface chemical analysis). This document contains no normative references; users may consult other ISO surface chemical analysis standards and manufacturer manuals for complementary procedures.
Keywords: ISO 24465:2023, surface plasmon resonance, SPR, minimum detectability, limit of detection, 3‑sigma rule, white‑light illumination, laser illumination, Kretschmann geometry, sensor chip, response unit.
Технические детали
- Технический комитет
- ISO/TC 201 - Surface chemical analysis
- SKU
- ISO 24465:2023
Похожие стандарты
Другие стандарты ISO
ISO 8689-1:2000
ДействующийWater quality — Biological classification of rivers — Part 1: Guidance on the interpretation of biological qu…
Overview ISO 8689-1:2000, titled Water quality - Biological classification of rivers - Part 1: Guidance on the interpretation of biological quality data from surveys of benthic macroinvertebrates, is…
ISO/ASTM51540-04(2012)
ОтменёнStandard Practice for Use of a Radiochromic Liquid Dosimetry System (Withdrawn 2020)
Significance and Use4.1 The radiochromic liquid dosimetry system provides a means of measuring absorbed dose in materials (5-7). Under the influence of ionizing radiation, chemical reactions take pla…
ISO/ASTM51204-04
ДействующийStandard Practice for Dosimetry in Gamma Irradiation Facilities for Food Processing (Withdrawn 2013)
Significance and Use4.1 Food products may be treated with ionizing radiation, such as gamma-rays from 60Co or 137Cs sources, for numerous purposes, including control of parasites and pathogenic micro…
ISO/ASTM51431-05
ОтменёнStandard Practice for Dosimetry in Electron Beam and X-Ray (Bremsstrahlung) Irradiation Facilities for Food P…
Significance and Use4.1 Food products may be treated with acceleratorgenerated radiation (electrons and X-rays) for numerous purposes, including control of parasites and pathogenic microorganisms, in…
ISO/ASTM52628-20e1
ДействующийStandard Practice for Dosimetry in Radiation Processing
1.1 This practice describes the basic requirements that apply when making absorbed dose measurements in accordance with the ASTM E61 series of dosimetry standards. In addition, it provides guidance o…
ISO/ASTM52921-13(2019)
ДействующийStandard Terminology for Additive Manufacturing—Coordinate Systems and Test Methodologies
Significance and Use 3.1 Although many additive manufacturing systems are based heavily upon the principles of Computer Numerical Control (CNC), the coordinate systems and nomenclature specific to CN…
ISO/ASTMTR52917-EB
ДействующийAdditive Manufacturing — Round Robin Testing — General Guidelines
This document outlines the steps with regard to aspects of design to conduct and run a round robin study (RRS) to assess the degree of variability in an additive manufacturing material or process. Th…
ISO/ASTM52901-17(2023)
ДействующийStandard Guide for Additive Manufacturing – General Principles – Requirements for Purchased AM Parts
Scope 1.1 This document defines and specifies requirements for purchased parts made by additive manufacturing. 1.2 It gives guidelines for the elements to be exchanged between the customer and the pa…