ISO 25387:2026 PDF
Microbeam analysis — Analytical electron microscopy — Procedures for determining the point resolution of high-resolution transmission electron microscope
Microbeam analysis — Analytical electron microscopy — Procedures for determining the point resolution of high-resolution transmission electron microscope
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 52
- Дата публикации:
- 9 июня 2026 г.
- Издание:
- ISO IS 25387 edition 1 version 1
- ICS:
- 37.020
This document specifies a procedure for determining the point resolution, called Scherzer resolution, of high-resolution transmission electron microscopes (HREM), which can visualize sample structure with sub-nanometre fineness. This document also specifies the measurement procedure of the real spherical aberration coefficient of the objective lens used. The procedure specified in this document for measuring the spherical aberration coefficient uses the dark rings that appear in the fast Fourier transform (FFT) pattern of HREM images of amorphous thin films, in which, at least three dark rings need to be observable near the Scherzer focus. Therefore, this document is applicable to HRTEMs equipped with a cold field emission gun (CFEG), Schottky emission gun (SEG) or thermal field emission gun (TFEG), or HREMs equipped with a thermionic emission gun (TEG) in which three or more dark rings can be clearly observed in the FFT pattern. This document does not treat the information limits, lattice resolution and STEM resolution. In addition, this document is not applicable to Cs-corrected TEM.
Abstract
Overview
ISO 25387:2026 provides a standardized procedure for determining the point resolution-specifically, the Scherzer resolution-of high-resolution transmission electron microscopes (HREM) used in microbeam analytical electron microscopy. This international standard outlines how to assess the microscopic performance of HREM through precise measurement of point resolution and real spherical aberration coefficients of the objective lens. The methodology relies on analyzing dark rings in the fast Fourier transform (FFT) pattern of HREM images from amorphous thin films, offering reliable and consistent results across different transmission electron microscopes (TEMs).
ISO 25387:2026 is applicable to HREMs equipped with various electron gun types-including cold field emission gun (CFEG), Schottky emission gun (SEG), thermal field emission gun (TFEG), and thermionic emission gun (TEG)-where three or more dark rings can be distinctly observed in the FFT pattern. Notably, this standard does not cover Cs-corrected TEM, information limits, lattice resolution, or STEM resolution.
Key Topics
- Scherzer Resolution: Defines point resolution for HREM, determined by the first zero in the phase contrast transfer function (PCTF) under the Scherzer focus condition.
- Measurement of Spherical Aberration: Specifies how to accurately assess the real spherical aberration coefficient-critical for evaluating TEM performance-by observing the diameters of dark rings in FFT patterns.
- FFT Pattern Analysis: Utilizes FFT diffractograms of amorphous thin film images, requiring at least three observable dark rings near the Scherzer focus.
- Applicable Electron Guns: Addresses CFEG, SEG, TFEG, and TEG types used across modern HREMs.
- Exclusions: Does not treat information limit, lattice resolution, STEM resolution, or Cs-corrected TEM.
- Impact of Envelope Functions: Discusses how spatial and temporal coherency affect the appearance of diffractograms, but not the actual measured point resolution.
Applications
Implementing ISO 25387:2026 ensures reliable, repeatable, and internationally comparable determination of HREM point resolution. Its practical applications include:
- Quality Control in Materials Science: Enables laboratories to verify HREM performance by regularly measuring and documenting point resolution, helping maintain consistent high-resolution imaging standards.
- Instrument Benchmarking: Provides a universal methodology for comparing instrument capabilities across manufacturers and research facilities, fostering standardization in equipment procurement and performance evaluation.
- Method Validation: Laboratories developing or validating analytical techniques involving HREM can use the protocol to ensure the accuracy of sub-nanometre structural observations.
- Research & Development: Assists researchers in materials science, nanotechnology, and life sciences to accurately characterize and report on ultra-fine material structures, forming the basis for reproducible and credible scientific investigations.
Related Standards
When applying ISO 25387:2026 in analytical electron microscopy, these related international standards may also be relevant:
- ISO 15932: Terminology for electron microscopy and microbeam analysis-critical for consistent definitions used in ISO 25387:2026.
- ISO 20263: Imaging methods for scanning transmission electron microscopes (STEM).
- Other ISO TC 202 Standards: Various documents on sample preparation, calibration, and performance criteria for electron microscopes.
- IEC Electropedia & ISO Online Browsing Platform: Reference sources for standard terms and abbreviations used in the field.
Conclusion
By adopting ISO 25387:2026, laboratories and researchers in analytical electron microscopy can confidently determine and report the point resolution of their HREM instruments. This standard delivers transparency, comparability, and precision for advanced imaging applications vital to material science, nanotechnology, and related fields, supporting global best practices in ultra-high-resolution electron microscopy.
Технические детали
- Технический комитет
- ISO/TC 202/SC 3 - Analytical electron microscopy
- SKU
- ISO 25387:2026
Похожие стандарты
Упомянутые в описании и другие стандарты ISO
ISO 15932:2013
ДействующийMicrobeam analysis — Analytical electron microscopy — Vocabulary
Overview ISO 15932:2013 - Microbeam analysis - Analytical electron microscopy - Vocabulary - is an international vocabulary standard that defines and organizes the terminology used in the practice of…
BS ISO 20263:2017
ОтменёнMicrobeam analysis. Analytical electron microscopy. Method for the determination of interface position in the…
1 Scope This document specifies a procedure for the determination of averaged interface position between two different layered materials recorded in the cross-sectional image of the multi-layered mat…
ISO 8689-1:2000
ДействующийWater quality — Biological classification of rivers — Part 1: Guidance on the interpretation of biological qu…
Overview ISO 8689-1:2000, titled Water quality - Biological classification of rivers - Part 1: Guidance on the interpretation of biological quality data from surveys of benthic macroinvertebrates, is…
ISO/ASTM51540-04(2012)
ОтменёнStandard Practice for Use of a Radiochromic Liquid Dosimetry System (Withdrawn 2020)
Significance and Use4.1 The radiochromic liquid dosimetry system provides a means of measuring absorbed dose in materials (5-7). Under the influence of ionizing radiation, chemical reactions take pla…
ISO/ASTM51204-04
ДействующийStandard Practice for Dosimetry in Gamma Irradiation Facilities for Food Processing (Withdrawn 2013)
Significance and Use4.1 Food products may be treated with ionizing radiation, such as gamma-rays from 60Co or 137Cs sources, for numerous purposes, including control of parasites and pathogenic micro…
ISO/ASTM51431-05
ОтменёнStandard Practice for Dosimetry in Electron Beam and X-Ray (Bremsstrahlung) Irradiation Facilities for Food P…
Significance and Use4.1 Food products may be treated with acceleratorgenerated radiation (electrons and X-rays) for numerous purposes, including control of parasites and pathogenic microorganisms, in…
ISO/ASTM52628-20e1
ДействующийStandard Practice for Dosimetry in Radiation Processing
1.1 This practice describes the basic requirements that apply when making absorbed dose measurements in accordance with the ASTM E61 series of dosimetry standards. In addition, it provides guidance o…
ISO/ASTM52921-13(2019)
ДействующийStandard Terminology for Additive Manufacturing—Coordinate Systems and Test Methodologies
Significance and Use 3.1 Although many additive manufacturing systems are based heavily upon the principles of Computer Numerical Control (CNC), the coordinate systems and nomenclature specific to CN…