ISO 28593:2017 PDF
Acceptance sampling procedures by attributes — Accept-zero sampling system based on credit principle for controlling outgoing quality
Acceptance sampling procedures by attributes — Accept-zero sampling system based on credit principle for controlling outgoing quality
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 9
- Дата публикации:
- 23 октября 2017 г.
- Издание:
- ISO IS 28593 edition 1 version 1
- ICS:
- 03.120.30
ISO 28593:2017 specifies a system of single sampling schemes for lot-by-lot inspection by attributes. All the sampling plans of the present system are of accept-zero form, i.e. no lot is accepted if the sample from it contains one or more nonconforming items. The schemes depend on a suitably-defined average outgoing quality limit (AOQL), the value of which is chosen by the user; no restrictions are placed on the choice of the value of the AOQL or on the sizes of successive lots in the series. The methodology ensures that the overall average quality reaching the customer or market-place will not exceed the AOQL in the long run.
Abstract
Overview
ISO 28593:2017 specifies an accept-zero, credit-based acceptance sampling system by attributes for controlling outgoing quality. The standard defines single sampling schemes for lot-by-lot inspection where a lot is accepted only if the inspected sample contains zero nonconforming items. Plans are driven by a user-selected average outgoing quality limit (AOQL) and the credit principle, which reduces sample sizes when a supplier demonstrates consistent good quality while protecting the customer if quality deteriorates.
Keywords: ISO 28593, acceptance sampling, accept-zero, AOQL, credit principle, lot-by-lot inspection, attributes.
Key topics and requirements
- Accept-zero sampling: No lot is accepted if the sample contains one or more nonconforming items.
- Average outgoing quality limit (AOQL): The user specifies an AOQL (upper limit on long-term average outgoing nonconforming rate). Sampling schemes ensure the expected AOQ will not exceed that AOQL in the long run.
- Credit principle: A running credit (K) accumulates by lot size for consecutive accepted lots. Higher credit generally reduces required sample sizes; credit resets to zero on non-acceptance.
- 100% inspection on certain non-accepted lots: If a lot is non-accepted when credit is zero, it must be 100% inspected and all conforming items allowed into the market - this preserves consumer protection.
- Applicability constraints:
- Series of lots from a single producer/process (apply separately per supplier).
- Quality characteristics must be classifiable as conforming/nonconforming (attribute inspection).
- Inspection must be non-destructive and classification error negligible.
- Operational notes: No restriction on AOQL value or successive lot sizes; sample sizes are integers and tend to be slightly conservative. For isolated or very short series of lots, realized AOQ can exceed AOQL though expected AOQ remains within limits.
Practical applications and users
ISO 28593 is practical where long-term control of outgoing quality is required with minimal inspection effort:
- Suppliers / Manufacturers - reduce inspection costs while incentivizing defect-free production through accumulated credit.
- Buyers / Quality Assurance Teams - enforce contract quality levels and set AOQLs to control market risk.
- Regulatory agencies - adopt for control programs where expected market quality must be limited and inspection resource efficiency is important.
- QC engineers and statisticians - design sampling plans, implement credit tracking and interpret AOQ/AOQL behavior.
Use cases: incoming acceptance of discrete items by attributes, serial production lines, supplier qualification programs, and regulatory product surveillance.
Related standards
ISO 28593 is part of the ISO 28590–28599 series on sampling by attributes. Related documents include:
- ISO 28590:2017 (series introduction)
- ISO 28591:2017 (sequential sampling)
- ISO 28592:2017 (double sampling)
- ISO 28594:2017 (combined accept-zero and process control)
For implementation, refer to the full ISO 28593:2017 text for sampling formulas, treatment rules and informative examples.
Технические детали
- Технический комитет
- ISO/TC 69/SC 5 - Acceptance sampling
- SKU
- ISO 28593:2017
Похожие стандарты
Стандарты, упомянутые в описании
ISO 28590:2017
ДействующийSampling procedures for inspection by attributes — Introduction to the ISO 2859 series of standards for sampl…
Overview ISO 28590:2017 - "Sampling procedures for inspection by attributes - Introduction to the ISO 2859 series" is a concise, general introduction to acceptance sampling by attributes and the ISO…
ISO 28591:2017
ДействующийSequential sampling plans for inspection by attributes
Overview ISO 28591:2017 - "Sequential sampling plans for inspection by attributes" - defines sequential sampling procedures for inspecting discrete items when conformity is recorded as attributes (co…
ISO 28592:2017
ДействующийDouble sampling plans by attributes with minimal sample sizes, indexed by producer's risk quality (PRQ) and c…
Overview ISO 28592:2017 (ISO 28592:2017) specifies double sampling plans by attributes with minimal sample sizes, indexed by producer’s risk quality (PRQ) and consumer’s risk quality (CRQ). It provid…
ISO 28594:2017
ДействующийCombined accept-zero sampling systems and process control procedures for product acceptance
Overview ISO 28594:2017 - Combined accept-zero sampling systems and process control procedures for product acceptance - specifies accept‑zero sampling systems and accompanying process‑control require…