ISO 3386-2:1997/Amd 1:2010 PDF
Flexible cellular polymeric materials — Determination of stress-strain characteristics in compression — Part 2: High-density materials — Amendment 1
Flexible cellular polymeric materials — Determination of stress-strain characteristics in compression — Part 2: High-density materials — Amendment 1
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 2
- Дата публикации:
- 9 апреля 2010 г.
- Издание:
- ISO IS 3386 edition 2 version 1
- ICS:
- 83.100
Abstract
Overview
ISO 3386-2:1997/Amd 1:2010 is an important international standard that specifies the method for determining the stress-strain characteristics in compression for high-density flexible cellular polymeric materials. This amendment enhances the 1997 second edition, focusing on material testing accuracy, conditioning requirements, and measurement standards for high-density flexible polymers such as foams used in various industrial and consumer applications.
The standard is published by the International Organization for Standardization (ISO), specifically developed by Technical Committee ISO/TC 45, focused on rubber and rubber products. It is essential for quality control and performance assessment of polymeric foam materials that exhibit complex compression behavior depending on their density and manufacturing conditions.
Key Topics
- Scope of Material Testing: Defines the compression test parameters specifically tailored for high-density flexible cellular polymeric materials, ensuring reliable benchmarking of material behavior.
- Test Machine Accuracy: Requires compression testing machines to conform to ISO 7500-1 Class 2 or better for force measurement, ensuring ±2% accuracy in test results.
- Conditioning Requirements: Specifies conditioning of test specimens at controlled temperatures (23 °C ± 2 °C or 27 °C ± 2 °C) and relative humidity (50% ± 5% or 65% ± 5%) for a minimum of 16 hours before testing to simulate in-service environments accurately.
- Timing of Tests: Recommends testing materials no sooner than 72 hours post-manufacture, while allowing earlier testing at 16 or 48 hours if results remain within ±10% variability compared to 72-hour results. For quality control, shorter conditioning and testing times are permitted under strict conditions.
- Reference Standards Integration: Incorporates related ISO standards such as:
- ISO 1923 for determining linear dimensions of cellular plastics and rubbers.
- ISO 2439 for hardness determination using indentation techniques.
- ISO 7500-1 for verification and calibration of the testing machine's force measurement.
Applications
- Material Quality Control: In manufacturing environments where high-density flexible cellular polymers are produced, this standard ensures consistent compression characteristics, vital for product performance and durability.
- Product Development and Testing: Enables R&D teams to standardize compression testing procedures, facilitating material selection and optimization for applications like cushioning, insulation, automotive components, and protective packaging.
- Compliance and Certification: Assists manufacturers and testing labs in meeting international quality standards, improving market access and customer confidence.
- Comparative Material Analysis: Provides a reliable method for comparing compression stress-strain behaviors between different polymeric materials or batches, supporting material innovation and fault diagnosis.
- Predictive Performance Modelling: Supports engineers in modeling product lifespan, comfort, and mechanical behavior under load conditions by providing accurate mechanical property data.
Related Standards
- ISO 1923 – Cellular plastics and rubbers: Determination of linear dimensions. Supports geometric consistency verification of test samples.
- ISO 2439 – Flexible cellular polymeric materials: Determination of hardness by indentation. Useful for correlating hardness with compression characteristics.
- ISO 7500-1 – Metallic materials: Verification of static uniaxial testing machines (tension/compression): Calibration of force measurement. Essential for ensuring test machine reliability.
- ISO/IEC Directives, Part 2 – Rules for drafting international standards, which guide the document’s structure and approval process.
This ISO 3386-2 amendment is crucial for industries relying on precise mechanical characterization of high-density flexible cell polymers, helping to maintain product quality, safety, and performance compliance globally. For comprehensive and standardized mechanical testing of flexible foams, implementing this standard translates into better product reliability and enhanced customer trust.
Технические детали
- Технический комитет
- ISO/TC 45/SC 4 - Products (other than hoses)
- SKU
- ISO 3386-2:1997/Amd 1:2010
Похожие стандарты
Стандарты, упомянутые в описании
ISO 3386-2:1997
ДействующийFlexible cellular polymeric materials — Determination of stress-strain characteristics in compression — Part…
Overview ISO 3386-2:1997 specifies a standardized laboratory method to determine the compression stress–strain characteristic of flexible cellular polymeric materials of density greater than 250 kg/m…
SIST EN ISO 7500-1:2018
ДействующийMetallic materials - Calibration and verification of static uniaxial testing machines - Part 1: Tension/compr…
Overview EN ISO 7500-1:2018 - "Metallic materials - Calibration and verification of static uniaxial testing machines - Part 1: Tension/compression testing machines - Calibration and verification of t…
BS EN ISO 19232-5:2018
ДействующийNon-destructive testing. Image quality of radiographs. Determination of the image unsharpness and basic spati…
SIST ISO 24394:2024
ДействующийWelding for aerospace applications - Qualification test for welders and welding operators - Fusion welding of…
Overview SIST ISO 24394:2024 - Welding for aerospace applications - Qualification test for welders and welding operators - Fusion welding of metallic components - defines minimum requirements for qua…