ISO 3743-1:2010 PDF
Acoustics — Determination of sound power levels and sound energy levels of noise sources using sound pressure — Engineering methods for small movable sources in reverberant fields — Part 1: Comparison method for a hard-walled test room
Acoustics — Determination of sound power levels and sound energy levels of noise sources using sound pressure — Engineering methods for small movable sources in reverberant fields — Part 1: Comparison method for a hard-walled test room
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 36
- Дата публикации:
- 21 сентября 2010 г.
- Издание:
- ISO IS 3743 edition 2 version 1
- ICS:
- 17.140.01
ISO 3743-1:2010 specifies methods for determining the sound power level or sound energy level of a noise source by comparing measured sound pressure levels emitted by this source (machinery or equipment) mounted in a hard-walled test room, the characteristics of which are specified, with those from a calibrated reference sound source. The sound power level (or, in the case of noise bursts or transient noise emission, the sound energy level) produced by the noise source, in frequency bands of width one octave, is calculated using those measurements. The sound power level or sound energy level with frequency A-weighting applied is calculated using the octave-band levels. The method specified in ISO 3743-1:2010 is suitable for all types of noise (steady, non-steady, fluctuating, isolated bursts of sound energy, etc.) defined in ISO 12001. The noise source under test may be a device, machine, component or sub-assembly. The maximum size of the source depends upon the size of the room used for the acoustical measurements (see 4.2). The test environment that is applicable for measurements made in accordance with ISO 3743-1:2010 is a hard-walled test room with prescribed acoustical characteristics. Information is given on the uncertainty of the sound power levels and sound energy levels determined in accordance with ISO 3743-1:2010, for measurements made in frequency octave bands and for A-weighted frequency calculations performed on them. The uncertainty conforms to ISO 12001:1996, accuracy grade 2 (engineering grade).
Abstract
Overview
ISO 3743-1:2010 - Acoustics - Determination of sound power levels and sound energy levels of noise sources using sound pressure - Part 1: Comparison method for a hard-walled test room - specifies an engineering-grade method for determining the sound power level and sound energy level of small, movable noise sources. The standard uses a comparison method: measured sound pressure levels from the test source in a prescribed hard-walled test room are compared with those from a calibrated reference sound source. Results are reported in one-octave frequency bands and can be combined to give A-weighted values.
Key topics and technical requirements
- Test environment: measurements are made in a hard-walled reverberant test room with defined acoustical characteristics; maximum source size is limited by room dimensions.
- Comparison method: sound power/energy is calculated from the difference between octave-band sound pressure levels of the test source and a reference source operated in the same room.
- Frequency range: nominal octave bands from 125 Hz to 8 000 Hz (extension down to 63 Hz allowed with caveats).
- Types of noise: suitable for steady, non-steady, fluctuating, burst or transient noises as defined in ISO 12001.
- Output formats: octave-band sound power levels and sound energy levels; derived A-weighted levels from those bands.
- Measurement uncertainty: uncertainty guidance is provided and conforms to ISO 12001:1996 accuracy grade 2 (engineering grade).
- Instrumentation and references: normative references include ISO 6926 (reference sources), IEC 60942 (calibrators), IEC 61672-1 (sound level meters) and IEC 61260 (filters).
Practical applications
- Determining the acoustic emission of portable machinery, appliances, components and sub-assemblies during product development, quality control and comparative testing.
- Evaluating noise emissions for product labeling, procurement specifications, or engineering design where laboratory-level (engineering-grade) accuracy is adequate.
- Measuring transient events (sound bursts) by reporting sound energy levels instead of continuous sound power.
- Benchmarking and troubleshooting noisy equipment in R&D or test laboratories using a hard-walled reverberant room.
Who should use ISO 3743-1:2010
- Acoustic test laboratories and in-house test facilities
- Product manufacturers (small appliances, portable equipment) and R&D teams
- Noise consultants and acoustic engineers performing emission testing
- Quality assurance specialists and procurement engineers comparing equipment noise performance
Related standards
- ISO 3740–3747 series (methods for sound power determination)
- ISO 3743-2 - Methods for special reverberation test rooms
- ISO 3741, ISO 9614 (higher-accuracy methods)
- ISO 12001 (noise test code rules)
- ISO 6926, IEC 60942, IEC 61672-1, IEC 61260
ISO 3743-1:2010 is practical for engineers and acoustic professionals who need an established, repeatable method to derive octave-band and A-weighted sound power/energy values for small, movable sources in a controlled reverberant environment.
Технические детали
- Технический комитет
- ISO/TC 43/SC 1 - Noise
- SKU
- ISO 3743-1:2010
Похожие стандарты
Стандарты, упомянутые в описании
ISO 12001:1996
ДействующийAcoustics — Noise emitted by machinery and equipment — Rules for the drafting and presentation of a noise tes…
Overview ISO 12001:1996 - Acoustics - Noise emitted by machinery and equipment - Rules for the drafting and presentation of a noise test code - defines the technical requirements for preparing a nois…
SIST EN ISO 12001:2009
ДействующийAcoustics - Noise emitted by machinery and equipment - Rules for the drafting and presentation of a noise tes…
Overview EN ISO 12001:2009 - titled Acoustics - Noise emitted by machinery and equipment - Rules for the drafting and presentation of a noise test code (ISO 12001:1996) - defines the technical requir…
ISO 6926:2016/Amd 1:2020
ДействующийAcoustics — Requirements for the performance and calibration of reference sound sources used for the determin…
Overview ISO 6926:2016/Amd 1:2020 is an important international amendment to the ISO 6926:2016 standard, focusing on acoustics-specifically, the requirements for the performance and calibration of re…
BS EN IEC 60942:2018
Electroacoustics. Sound calibrators
What is BS EN IEC 60942- Electroacoustics – Sound calibrators about? BS EN IEC 60942 specifies the performance requirements for three classes of sound calibrators of class LS (Laboratory Standard), c…
IEC 61672-1:2013
ДействующийElectroacoustics - Sound level meters - Part 1: Specifications
Overview IEC 61672-1:2013 is an international standard published by the International Electrotechnical Commission (IEC) that specifies the performance requirements for sound level meters used in elec…
IEC 61260-1:2014
ДействующийElectroacoustics - Octave-band and fractional-octave-band filters - Part 1: Specifications
Overview IEC 61260-1:2014 is an international standard developed by the International Electrotechnical Commission (IEC) that specifies the performance requirements for octave-band and fractional-octa…
SIST EN ISO 3743-2:2019
ДействующийAcoustics - Determination of sound power levels of noise sources using sound pressure - Engineering methods f…
Overview EN ISO 3743-2:2019 (adopted from ISO 3743-2:2018) is a CEN standard for acoustics that specifies an engineering method to determine sound power levels from sound pressure measurements. It is…