ISO 4518:2021 PDF
Metallic coatings — Measurement of coating thickness — Profilometric method
Metallic coatings — Measurement of coating thickness — Profilometric method
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 8
- Дата публикации:
- 8 апреля 2021 г.
- Издание:
- ISO IS 4518 edition 2 version 1
- ICS:
- 25.220.40
This document specifies a method for the measurement of metal coating thickness by first forming a step between the surface of the coating and the surface of its substrate and then measuring the step height using a profile recording instrument. It covers the instrumentation characteristics and the procedure appropriate to this specific application of profilometric methods. The method is applicable to the measurement of thicknesses of metal coatings from 0,01 µm to 1 000 µm on flat surfaces and, if appropriate precautions are taken, on cylindrical surfaces. It is highly suitable for the measurement of minute thicknesses but, for thicknesses of less than 0,01 µm, surface flatness and surface smoothness are very critical and, accordingly, the method is not suitable for use down to the lowest level of measurement usual for electronic stylus instruments. The method is suitable for measuring coating thicknesses when preparing coating thickness reference standards.
Abstract
Overview
ISO 4518:2021 - Metallic coatings: Measurement of coating thickness - Profilometric method - defines a profilometric procedure for measuring metal coating thickness by creating a step between coating and substrate and measuring the step height with a profile recording instrument. The standard covers instrumentation, operational parameters, measurement procedure and accuracy considerations for thicknesses from 0.01 µm to 1 000 µm on flat surfaces (and on cylindrical surfaces with precautions). It is particularly suitable for minute thicknesses and for preparing coating thickness reference standards.
Key topics and technical requirements
- Measurement principle
- Form a step by dissolving part of the coating or by masking before coating, then measure step height with a profilometer.
- Instrument types covered
- Contact stylus instruments (surface analysers / profile recorders): traverse 1–100 mm; thickness range ~0.005 µm to 250 µm; height resolution from 0.0005 µm to 1 µm. Stylus tip radii: 2, 5, 10, 50 µm with specified maximum static forces (e.g., 0.7–16 mN depending on tip radius).
- Inductive measuring probes / displacement sensors: typical linearity ≥ 0.5%; measurement range ~1 µm to 1 000 µm; height resolution 0.02 µm to 20 µm.
- Optical profilometers (white‑light interference, confocal, laser‑scanning, chromatic confocal): excellent height resolution (down to ~0.5 nm); measurement range dependent on surface roughness and instrument.
- Accuracy and operational factors
- Profile fidelity, vertical/horizontal magnification, datum alignment, applied stylus force, stylus radius vs surface roughness, vibrations, surface curvature, cleanliness, temperature and calibration.
- Procedure elements
- Preparation of the step, profile recording, thickness evaluation, calibration and reporting requirements.
Applications and who uses it
- Quality control and acceptance testing of electroplated and metallic coatings.
- Production inspection (masking technique) and laboratory validation (dissolution technique).
- Preparation and verification of coating thickness reference standards.
- Typical users: metallurgists, surface metrology labs, coating engineers, QA/QC personnel in automotive, aerospace, electronics, and industrial plating sectors, and manufacturers of precision components requiring traceable thickness measurements.
Practical value
- Enables high‑accuracy thickness measurement across micro- to sub-millimetre ranges with multiple instrument options.
- Advises on minimizing error sources (stylus selection, force control, datum alignment, calibration) to achieve reproducible, traceable measurements.
- Incorporates modern optical profilometry methods in addition to traditional stylus techniques (2021 revision).
Related standards
- Normative reference: ISO 2177 (Coulometric method by anodic dissolution) - useful complementary method for coating thickness determination.
Keywords: ISO 4518:2021, metallic coatings, coating thickness measurement, profilometric method, profilometer, stylus, optical profilometer, confocal microscope, white‑light interference.
Технические детали
- Технический комитет
- ISO/TC 107 - Metallic and other inorganic coatings
- SKU
- ISO 4518:2021
Похожие стандарты
Упомянутые в описании и другие стандарты ISO
BS ISO 21771-2:2025
ДействующийCylindrical involute gears and gear pairs. Calculation and measurement of tooth thickness and backlash.
ISO 8689-1:2000
ДействующийWater quality — Biological classification of rivers — Part 1: Guidance on the interpretation of biological qu…
Overview ISO 8689-1:2000, titled Water quality - Biological classification of rivers - Part 1: Guidance on the interpretation of biological quality data from surveys of benthic macroinvertebrates, is…
ISO/ASTM51540-04(2012)
ОтменёнStandard Practice for Use of a Radiochromic Liquid Dosimetry System (Withdrawn 2020)
Significance and Use4.1 The radiochromic liquid dosimetry system provides a means of measuring absorbed dose in materials (5-7). Under the influence of ionizing radiation, chemical reactions take pla…
ISO/ASTM51204-04
ДействующийStandard Practice for Dosimetry in Gamma Irradiation Facilities for Food Processing (Withdrawn 2013)
Significance and Use4.1 Food products may be treated with ionizing radiation, such as gamma-rays from 60Co or 137Cs sources, for numerous purposes, including control of parasites and pathogenic micro…
ISO/ASTM51431-05
ОтменёнStandard Practice for Dosimetry in Electron Beam and X-Ray (Bremsstrahlung) Irradiation Facilities for Food P…
Significance and Use4.1 Food products may be treated with acceleratorgenerated radiation (electrons and X-rays) for numerous purposes, including control of parasites and pathogenic microorganisms, in…
ISO/ASTM52628-20e1
ДействующийStandard Practice for Dosimetry in Radiation Processing
1.1 This practice describes the basic requirements that apply when making absorbed dose measurements in accordance with the ASTM E61 series of dosimetry standards. In addition, it provides guidance o…
ISO/ASTM52921-13(2019)
ДействующийStandard Terminology for Additive Manufacturing—Coordinate Systems and Test Methodologies
Significance and Use 3.1 Although many additive manufacturing systems are based heavily upon the principles of Computer Numerical Control (CNC), the coordinate systems and nomenclature specific to CN…
ISO/ASTMTR52917-EB
ДействующийAdditive Manufacturing — Round Robin Testing — General Guidelines
This document outlines the steps with regard to aspects of design to conduct and run a round robin study (RRS) to assess the degree of variability in an additive manufacturing material or process. Th…