ISO 52016-3:2023 PDF
Energy performance of buildings — Energy needs for heating and cooling, internal temperatures and sensible and latent heat loads — Part 3: Calculation procedures regarding adaptive building envelope elements
Energy performance of buildings — Energy needs for heating and cooling, internal temperatures and sensible and latent heat loads — Part 3: Calculation procedures regarding adaptive building envelope elements
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 55
- Дата публикации:
- 29 сентября 2023 г.
- Издание:
- ISO IS 52016 edition 1 version 1
- ICS:
- 91.120.10
This document specifies procedures for the calculation of the energy needs for heating and cooling, internal temperatures and sensible and latent heat loads of a building according to the hourly calculation methodology in ISO 52016-1. Additions or modifications of the calculations are provided in this document if the building envelope contains one or more adaptive building envelope elements (building envelope elements with adaptive components that are either environmentally or actively controlled as a function of specific conditions). The adaptive building envelope element replaces the transparent building element in the calculation according to ISO 52016-1. The three types of adaptive building envelope elements covered in this document are: — building envelope elements with dynamic solar shading; — building envelope elements with chromogenic glazing; — building envelope elements with an actively ventilated cavity. Environmentally activated control is described for building envelope elements with chromogenic glazing, but can also occur for other types of adaptive building envelope elements. In that case the same approach applies as for environmentally activated chromogenic glazing. This document is applicable to the assessment of the energy performance of buildings (EPB) (energy performance labels and certificates), including comparison between buildings and checking conformity with minimum energy performance criteria. It is also applicable to assess the contribution of the adaptive building envelope element to the smart readiness of a building. In addition, this document provides indicators for the impact of the adaptive building envelope element on the performance of the building compared to a reference building envelope element. It is applicable to buildings at the design stage, to new buildings after construction and to existing buildings in the use phase. This document is not applicable to geometrically complex adaptive building envelope elements that can only be modelled as multiple coupled thermal zones. NOTE The background to the selection of adaptive building envelope elements is given in ISO/TR 52016-4.
Abstract
Overview
ISO 52016-3:2023 defines calculation procedures for assessing the energy needs for heating and cooling, internal temperatures, and sensible and latent heat loads for buildings that include adaptive building envelope elements. Built on the hourly calculation methodology of ISO 52016-1, this part provides additions and modifications where glazing or façade components are dynamic or actively controlled. It applies to building design, new construction and existing buildings in use, and supports energy performance certification, comparison and conformity checks.
Key topics and requirements
- Scope of adaptive elements: covers three types - dynamic solar shading, chromogenic glazing, and actively ventilated cavities. Environmentally activated control approaches are defined for chromogenic glazing and can be applied to other element types.
- Calculation basis: uses the hourly calculation methodology in ISO 52016-1; ISO 52016-3 takes precedence where procedures conflict.
- Model options: defines simplified and detailed models for adaptive building envelope elements with specific input data sets and property definitions.
- Control modelling: prescribes methods to model both environmentally activated and actively controlled scenarios, including selection of sensors, events/conditions, control strategies and user behaviour modelling.
- Inputs and outputs: specifies required climatic, physical and control-related input data; outputs include energy needs for heating/cooling, internal temperatures, sensible/latent loads and performance indicators relative to a reference element.
- Quality and conformity: includes provisions for quality control and conformance checks. Annexes provide templates (Annex A), default choices (Annex B) and reference control scenarios (Annex C).
- Limits: not applicable to geometrically complex adaptive elements that require multi-zone coupling.
Applications and users
- Primary users: architects, building-energy engineers, regulators and certification bodies conducting Energy Performance of Buildings (EPB) assessments.
- Secondary users: manufacturers and suppliers of adaptive façade components, building owners and consultants evaluating retrofit options.
- Practical uses:
- Calculating and comparing building energy needs for compliance, energy performance labels and certificates.
- Quantifying the contribution of adaptive envelope elements to smart readiness and operational energy savings.
- Informing design optimization, product specification (dynamic shading, chromogenic glass, ventilated cavities) and cost-benefit analysis for retrofits.
Related standards
- ISO 52016-1 (hourly calculation methodology) - foundational calculation approach referenced throughout.
- ISO/TR 52016-4 - background and justification for selecting adaptive building envelope elements.
- Other EPB module standards referenced via the EPB modular framework for integrated energy performance assessment.
Keywords: ISO 52016-3:2023, adaptive building envelope, dynamic solar shading, chromogenic glazing, actively ventilated cavity, energy performance of buildings, energy needs for heating and cooling, ISO 52016-1, hourly calculation methodology, EPB.
Технические детали
- Технический комитет
- ISO/TC 163/SC 2 - Calculation methods
- SKU
- ISO 52016-3:2023
Похожие стандарты
Стандарты, упомянутые в описании
SIST-TP CEN ISO/TR 52016-2:2017
ДействующийEnergy performance of buildings - Energy needs for heating and cooling, internal temperatures and sensible an…
Overview CEN ISO/TR 52016-2:2017 (ISO/TR 52016-2:2017) is a Technical Report published by CEN to explain and justify the calculation methods given in ISO 52016‑1 and ISO 52017‑1. It is an explanatory…
SIST EN ISO 52016-3:2024/A1:2025
ДействующийEnergy performance of buildings - Energy needs for heating and cooling, internal temperatures and sensible an…
Overview EN ISO 52016-3:2023/A1:2025 is an amendment to ISO 52016‑3 that extends and clarifies the calculation procedures for adaptive building envelope elements. It adds normative, harmonized refere…
SIST-TP CEN ISO/TR 52016-4:2025
ДействующийEnergy performance of buildings - Energy needs for heating and cooling, internal temperatures and sensible an…
Overview SIST-TP CEN ISO/TR 52016-4:2025 provides detailed explanation and justification for the correct understanding and use of ISO 52016-3, which addresses the calculation of energy needs for heat…