ISO 6892-3:2015 specifies a method of tensile testing of metallic materials at temperatures between +10 °C and -196 °C.
Abstract
Overview
ISO 6892-3:2015 - "Metallic materials - Tensile testing - Part 3: Method of test at low temperature" specifies a standardized method for tensile testing of metallic materials at temperatures between +10 °C and −196 °C. It is part of the ISO 6892 series for tensile testing and provides procedures, equipment requirements, and documentation rules for reliable, reproducible low-temperature tensile tests (cryogenic testing).
Key Topics and Requirements
- Scope and principle: Tensile testing to determine mechanical properties of metallic materials at low temperatures; stresses are calculated using original cross-sectional area measured at room temperature.
- Temperature range and control: Tests performed between +10 °C and −196 °C; includes requirements for cooling devices, temperature measurement, verification and soaking time (time to stabilize test-piece temperature).
- Test pieces and dimensions: Test-piece geometries and gauge lengths are specified; original gauge length (Lo) and extensometer gauge length (Le) are measured at room temperature unless otherwise agreed.
- Force measuring system: Must be calibrated per ISO 7500-1, class 1 or better.
- Extensometer requirements: Use ISO 9513 extensometers - class 1 for proof strength measurements, class 2 acceptable for larger extensions. Extensometer gauge length shall be ≥ 10 mm and correspond to the central portion of the parallel length.
- Testing methods and strain rates: Two methods are defined:
- Method A - strain-rate-based testing with narrow tolerances (intended to minimize variability and measurement uncertainty).
- Method B - conventional strain rate ranges (expanded ranges). Choice of method and strain rates aligns with ISO 6892-1 and ISO 6892-2 updates.
- Measurement and reporting: Procedures for determining tensile strength, yield/proof strength, percentage elongation, reduction of area, and reporting; includes guidance on measurement uncertainty and required test report content.
- Safety warning: Standard notes hazards associated with cryogens and procedures; users must establish safe work practices.
Practical Applications and Users
ISO 6892-3 is used by:
- Materials testing laboratories performing cryogenic tensile tests (e.g., liquid nitrogen).
- Manufacturers and suppliers of metals and alloys requiring low-temperature mechanical property verification (pipeline steels, aerospace alloys, cryogenic storage vessels).
- Design engineers, quality assurance teams, and certification bodies needing standardized test data for low-temperature performance, yield/tensile strength, and elongation.
- Research organizations studying temperature-dependent mechanical behavior of metallic materials.
Keywords: ISO 6892-3, tensile testing, low temperature, metallic materials, cryogenic testing, extensometer, ISO 7500-1, ISO 9513, strain rate.
Related Standards
- ISO 6892-1:2009 - Method of test at room temperature
- ISO 6892-2 - Method of test at elevated temperature
- ISO 6892-4 - Method of test in liquid helium
- ISO 7500-1 - Calibration of force-measuring systems
- ISO 9513 - Calibration of extensometer systems
This standard ensures consistent, comparable low-temperature tensile test results for materials selection, qualification, and research.
Технические детали
- Технический комитет
- ISO/TC 164/SC 1 - Uniaxial testing
- SKU
- ISO 6892-3:2015
Похожие стандарты
Стандарты, упомянутые в описании
ISO 6892-1:2009
ОтменёнMetallic materials — Tensile testing — Part 1: Method of test at room temperature
BS EN ISO 6892-2:2026
ДействующийMetallic materials. Tensile testing - Method of test at elevated temperature
1 Scope This document specifies a method of tensile testing of metallic materials at temperatures higher than room temperature.
SIST EN ISO 7500-1:2018
ДействующийMetallic materials - Calibration and verification of static uniaxial testing machines - Part 1: Tension/compr…
Overview EN ISO 7500-1:2018 - "Metallic materials - Calibration and verification of static uniaxial testing machines - Part 1: Tension/compression testing machines - Calibration and verification of t…
SIST EN ISO 9513:2013/AC:2014
ДействующийMetallic materials - Calibration of extensometer systems used in uniaxial testing - Technical Corrigendum 1 (…
SIST EN ISO 6892-1:2020
ДействующийMetallic materials - Tensile testing - Part 1: Method of test at room temperature (ISO 6892-1:2019)
Overview SIST EN ISO 6892-1:2020 (ISO 6892-1:2019) specifies the standardized method for tensile testing of metallic materials at room temperature. The document defines the test procedure, required t…
SIST EN ISO 6892-3:2015
ДействующийMetallic materials - Tensile testing - Part 3: Method of test at low temperature (ISO 6892-3:2015)
Overview EN ISO 6892-3:2015 - Metallic materials - Tensile testing - Part 3: Method of test at low temperature specifies a standardized method for tensile testing of metallic materials at temperature…