ISO 7109:1985 PDF
Ammonia solution for industrial use — Determination of residue after evaporation at 105 degrees C — Gravimetric method
Ammonia solution for industrial use — Determination of residue after evaporation at 105 degrees C — Gravimetric method
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 1
- Дата публикации:
- 30 мая 1985 г.
- Издание:
- ISO IS 7109 edition 1 version 1
- ICS:
- 71.060.40
A test portion is evaporated in a tared platinum dish and the residue is weighed after drying at 105 2 °C. The method is applicable to solutions containing not more than 35 % (m/m) ammonia.
Abstract
Overview
ISO 7109:1985 specifies a simple, reproducible gravimetric method to determine the residue after evaporation of industrial ammonia solutions. The test evaporates a measured portion of sample in a tared platinum dish, dries the remaining residue at 105 ± 2 °C, and reports the residue mass as mg/kg. The method is applicable to ammonia solutions containing not more than 35% (m/m) ammonia and is intended for routine quality control and specification testing.
Key topics and requirements
- Scope: Determines non-volatile residue after evaporation for industrial ammonia solutions up to 35% (m/m).
- Safety: Operations must be carried out in a well‑ventilated fume cupboard due to ammonia vapors.
- Apparatus: Ordinary laboratory equipment including a tared platinum dish (~75 mm diameter), a 500 ml one‑mark volumetric flask for the test portion, and an electric oven maintainable at 105 ± 2 °C.
- Procedure:
- Prepare a test portion by filling a 500 ml volumetric flask with the laboratory sample.
- Weigh the dried, tared platinum dish to 0.0001 g accuracy.
- Pour a measured volume into the dish and evaporate to dryness on a boiling water bath in a fume cupboard, adding more sample until all liquid is removed.
- Dry the dish in the oven at 105 ± 2 °C (minimum 30 min), cool in a desiccator, and weigh the residue.
- Calculation: Residue (mg/kg) is calculated as:
- Residue = ((m1 − m0) × 10^6) / (V × Q)
- where m0 = mass of empty dish (g), m1 = mass of dish + residue (g), V = volume of test portion (mL), Q = density of sample (g/mL).
- Reference: The standard cites ISO documents for determination of density (ISO 750 / ISO 758 are referenced in the text).
Applications and users
ISO 7109 is used by:
- Chemical manufacturers producing industrial ammonia solutions for quality-control release testing.
- Analytical laboratories performing routine gravimetric analysis of ammonia products.
- Regulatory and inspection laboratories verifying product conformity to specifications.
- Process and QC engineers who need a standardized method to quantify non‑volatile residues that can affect downstream processes, equipment scaling, or product purity.
Practical applications include batch acceptance testing, trend monitoring of impurities, and specification verification for suppliers and purchasers of industrial ammonia.
Related standards
- ISO 750 / ISO 758 (density determination) - referenced for sample density Q used in calculations.
- Other ISO chemical product methods prepared by ISO/TC 47 (Chemistry) for complementary analyses of industrial liquids.
Keywords: ISO 7109, ammonia solution, residue after evaporation, gravimetric method, 105 °C, industrial ammonia, platinum dish, analytical method, quality control.
Технические детали
- Технический комитет
- ISO/TC 47 - Chemistry
- SKU
- ISO 7109:1985
Похожие стандарты
Упомянутые в описании и другие стандарты ISO
SIST ISO 7503-1:2025
ДействующийMeasurement of radioactivity - Measurement and evaluation of surface contamination - Part 1: General principl…
Overview SIST ISO 7503-1:2025 - Measurement of radioactivity: Measurement and evaluation of surface contamination - Part 1: General principles provides high-level guidance for assessing radioactive c…
BS ISO 7588-1:1998
Road vehicles. Electrical/electronic switching devices - Relays and flashers
1 Scope This part of ISO 7588 specifies dimensional characteristics and the functional allocation of relay and flasher terminals intended for road vehicles. Annex A gives additional information on th…
ISO 8689-1:2000
ДействующийWater quality — Biological classification of rivers — Part 1: Guidance on the interpretation of biological qu…
Overview ISO 8689-1:2000, titled Water quality - Biological classification of rivers - Part 1: Guidance on the interpretation of biological quality data from surveys of benthic macroinvertebrates, is…
ISO/ASTM51540-04(2012)
ОтменёнStandard Practice for Use of a Radiochromic Liquid Dosimetry System (Withdrawn 2020)
Significance and Use4.1 The radiochromic liquid dosimetry system provides a means of measuring absorbed dose in materials (5-7). Under the influence of ionizing radiation, chemical reactions take pla…
ISO/ASTM51204-04
ДействующийStandard Practice for Dosimetry in Gamma Irradiation Facilities for Food Processing (Withdrawn 2013)
Significance and Use4.1 Food products may be treated with ionizing radiation, such as gamma-rays from 60Co or 137Cs sources, for numerous purposes, including control of parasites and pathogenic micro…
ISO/ASTM51431-05
ОтменёнStandard Practice for Dosimetry in Electron Beam and X-Ray (Bremsstrahlung) Irradiation Facilities for Food P…
Significance and Use4.1 Food products may be treated with acceleratorgenerated radiation (electrons and X-rays) for numerous purposes, including control of parasites and pathogenic microorganisms, in…
ISO/ASTM52628-20e1
ДействующийStandard Practice for Dosimetry in Radiation Processing
1.1 This practice describes the basic requirements that apply when making absorbed dose measurements in accordance with the ASTM E61 series of dosimetry standards. In addition, it provides guidance o…
ISO/ASTM52921-13(2019)
ДействующийStandard Terminology for Additive Manufacturing—Coordinate Systems and Test Methodologies
Significance and Use 3.1 Although many additive manufacturing systems are based heavily upon the principles of Computer Numerical Control (CNC), the coordinate systems and nomenclature specific to CN…