ISO 7199:2024 PDF
Cardiovascular implants and artificial organs — Blood-gas exchangers (oxygenators)
Cardiovascular implants and artificial organs — Blood-gas exchangers (oxygenators)
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 22
- Дата публикации:
- 5 сентября 2024 г.
- Издание:
- ISO IS 7199 edition 4 version 1
- ICS:
- 11.040.40
This document specifies requirements for sterile, single-use, extracorporeal blood-gas exchangers (oxygenators) intended for the supply of oxygen to, and the removal of carbon dioxide from, human blood, during cardiopulmonary bypass (CPB) for up to 6 h, extracorporeal lung assist [ECLA with veno-venous (VV), veno-arterial (VA) or veno-arterial-venous (VAV) cannulation strategies], cardiopulmonary support (CPS), extracorporeal life support (ECLS with VA cannulation strategy), extracorporeal carbon dioxide removal (ECCO2R), and other extracorporeal circulation techniques requiring blood-gas exchange. This document also applies to heat exchangers and arterial filters that are integral parts of the oxygenator. This document also applies to external equipment unique to the use of the oxygenator. This document does not apply to — implanted oxygenators, — liquid oxygenators, — extracorporeal circuits (blood tubing), — separate heat exchangers, — separate ancillary devices, and — separate arterial line filters.
Abstract
Overview
ISO 7199:2024 - "Cardiovascular implants and artificial organs - Blood‑gas exchangers (oxygenators)" specifies requirements for sterile, single‑use extracorporeal oxygenators used for oxygenation and CO2 removal in procedures such as cardiopulmonary bypass (CPB, up to 6 h), extracorporeal lung assist (ECLA: VV, VA, VAV), cardiopulmonary support (CPS), extracorporeal life support (ECLS with VA), and extracorporeal carbon dioxide removal (ECCO2R). The standard also covers oxygenators that incorporate integral heat exchangers and arterial filters, plus external equipment unique to oxygenator use. It excludes implanted or liquid oxygenators, separate heat exchangers, tubing circuits and separate ancillary devices.
Key topics and technical requirements
ISO 7199:2024 defines mandatory topics manufacturers and test labs must address, including:
- Biological characteristics
- Sterility and non‑pyrogenicity
- Biocompatibility per risk management
- Physical characteristics
- Blood pathway and heat exchanger fluid pathway integrity
- Priming and blood volumes, connectors and compatibility
- Performance characteristics
- Oxygen and carbon dioxide transfer rates (gas transfer)
- Heat exchanger performance factor
- Integral arterial filtration efficiency, flow capacity and air‑handling capability
- Blood cell damage (haemolysis, platelet and white cell reduction)
- Time‑dependent performance and shelf life
- Testing and reporting
- Type tests and measurement protocols for gas transfer, heat exchange and blood cell damage
- Minimum reporting requirements so users can compare oxygenator performance
- Labelling, information and packaging
- Manufacturer information, unit and shipping container requirements, and accompanying documentation
Note: ISO 7199 provides evaluation procedures and reporting requirements but does not specify numeric performance limits. It also records editorial updates such as addition of a priming volume definition and corrections to certain blood‑damage definitions.
Practical applications and users
ISO 7199 is used to:
- Guide device manufacturers in design verification, production controls and clinical labeling for oxygenators
- Define test protocols for independent test laboratories and QA/validation teams
- Support regulatory submissions and procurement specifications in hospitals
- Help clinical perfusionists and biomedical engineers compare device performance for specific extracorporeal therapies
Keywords: oxygenators, blood‑gas exchangers, extracorporeal, CPB, ECLS, ECCO2R, heat exchanger, arterial filter, single‑use, sterility, biocompatibility.
Related standards
ISO 7199 references and aligns with other standards relevant to medical device safety and sterilization, including:
- ISO 10993‑1, ISO 10993‑11 (biological evaluation)
- ISO 11135, ISO 11137‑1, ISO 17665 (sterilization processes)
- ISO 11607‑1/‑2 (packaging for terminally sterilized devices)
- ISO 80369‑7 (connectors for intravascular applications)
Use ISO 7199 when specifying, testing or procuring extracorporeal oxygenators to ensure consistent safety, performance reporting and comparability across devices.
Технические детали
- Технический комитет
- ISO/TC 150/SC 2 - Cardiovascular implants and extracorporeal systems
- SKU
- ISO 7199:2024
Похожие стандарты
Стандарты, упомянутые в описании
SIST EN ISO 7199:2024
ДействующийCardiovascular implants and artificial organs - Blood-gas exchangers (oxygenators) (ISO 7199:2024)
Overview EN ISO 7199:2024 (Cardiovascular implants and artificial organs - Blood-gas exchangers (oxygenators)) is the CEN-adopted, fourth-edition international standard specifying safety, performance…
BS EN ISO 10993-11:2018
ДействующийBiological evaluation of medical devices. Tests for systemic toxicity.
ISO 11135:2014/Amd 1:2018
ДействующийSterilization of health-care products — Ethylene oxide — Requirements for the development, validation and rou…
Overview ISO 11135:2014/Amd 1:2018 is an important amendment to the international standard for the sterilization of health-care products using ethylene oxide. This standard outlines the requirements…
ISO 11137-1:2006/Amd 2:2018
ОтменёнSterilization of health care products — Radiation — Part 1: Requirements for development, validation and rout…
Overview ISO 11137-1:2006/Amd 2:2018 is an important amendment to the international standard for the sterilization of healthcare products using radiation. This document focuses on requirements for th…
SIST EN ISO 17665:2024
ДействующийSterilization of health care products - Moist heat - Requirements for the development, validation and routine…
Overview EN ISO 17665:2024 - Sterilization of health care products - Moist heat - Requirements for the development, validation and routine control of a sterilization process for medical devices - spe…
ISO 11607-1:2019/Amd 1:2023
ДействующийPackaging for terminally sterilized medical devices — Part 1: Requirements for materials, sterile barrier sys…
Overview ISO 11607-1:2019/Amd 1:2023 is an essential amendment to the international standard governing packaging for terminally sterilized medical devices. This document focuses on the requirements f…
SIST EN ISO 80369-7:2021
ДействующийSmall-bore connectors for liquids and gases in healthcare applications - Part 7: Connectors for intravascular…
Overview EN ISO 80369-7:2021 (ISO 80369-7:2021) defines the dimensions and functional performance requirements for small-bore connectors used in intravascular and hypodermic applications. It covers c…