A method of determining the dynamic viscosity of glass by measuring the elongation a glass fibre under a defined uniaxial stress. In addition the viscosity-temperature relationship and the dependence of the viscosity on the thermal history can be checked. The theoretical basis relation and the apparatus including the method of measuring are specified.
Abstract
Overview
ISO 7884-3:1987 - "Glass - Viscosity and viscometric fixed points - Part 3: Determination of viscosity by fibre elongation viscometer" specifies a laboratory method to determine the dynamic viscosity of glass by measuring the elongation of a drawn glass fibre under a defined uniaxial stress. The procedure also supports checking the viscosity–temperature relationship and the effect of thermal history on viscosity. The standard defines the theoretical basis, required apparatus, measurement practice and necessary corrections.
Key topics and technical requirements
- Measurement principle: viscosity is derived from the timed elongation of a cylindrical glass fibre under a constant gravitational load, assuming Newtonian behaviour and negligible elastic response.
- Viscosity range: the method is intended primarily for high viscosities (the document addresses values up into the 10^8–10^13 dPa·s region), covering the softening and glass-transition domain important for viscometric fixed points.
- Apparatus and controls:
- Electrically heated furnaces (working up to ~900 °C) with accurate time–temperature programming and stability (temperature constancy to ±1 °C; gradients along the specimen ≤0.2 °C/cm).
- Thermocouples: low-inertia types (IEC type S or K) with calibration and regular checks; measurement junctions positioned close to the specimen.
- Hanging/support geometry: fused‑silica supports or platinic rods to hold the upper ball and loading linkage; loading pieces (brass weights) as dead-weights.
- Elongation measurement: markers, travelling microscope or transducers with minimum sensitivity ~0.02 mm; fibre diameter measured by micrometer (resolution ~0.005 mm).
- Sample preparation: flame-working or electric furnace melting; fibres with homogeneous, bubble‑free material and uniform cross-section.
- Corrections & checks: account for dead-weight distribution and surface-tension forces; use equations provided in the standard to calculate viscosity from measured elongation and time.
Applications and typical users
- Use cases:
- Determining dynamic viscosity for research, process control and R&D on glass formulations.
- Establishing viscosity–temperature curves and assessing the influence of thermal history (annealing, cooling rates).
- Supporting characterization of viscometric fixed points, softening and transition behaviour.
- Typical users:
- Glass technologists, materials scientists, laboratory metrologists, quality-control teams in glass production, and standards or calibration laboratories.
Related standards and references
- ISO 7884 series (other parts cover alternative viscometry methods and fixed points: beam bending, softening point, annealing/strain points, etc.).
- IEC thermocouple standards (IEC 584 series) for thermocouple types and tables referenced by ISO 7884-3.
Keywords: ISO 7884-3, glass viscosity, fibre elongation viscometer, viscometry, viscosity–temperature relationship, viscometric fixed points, glass testing, thermocouples, laboratory procedure.
Технические детали
- Технический комитет
- ISO/TC 48 - Laboratory equipment
- SKU
- ISO 7884-3:1987
Похожие стандарты
Другие стандарты ISO
ISO 8689-1:2000
ДействующийWater quality — Biological classification of rivers — Part 1: Guidance on the interpretation of biological qu…
Overview ISO 8689-1:2000, titled Water quality - Biological classification of rivers - Part 1: Guidance on the interpretation of biological quality data from surveys of benthic macroinvertebrates, is…
ISO/ASTM51540-04(2012)
ОтменёнStandard Practice for Use of a Radiochromic Liquid Dosimetry System (Withdrawn 2020)
Significance and Use4.1 The radiochromic liquid dosimetry system provides a means of measuring absorbed dose in materials (5-7). Under the influence of ionizing radiation, chemical reactions take pla…
ISO/ASTM51204-04
ДействующийStandard Practice for Dosimetry in Gamma Irradiation Facilities for Food Processing (Withdrawn 2013)
Significance and Use4.1 Food products may be treated with ionizing radiation, such as gamma-rays from 60Co or 137Cs sources, for numerous purposes, including control of parasites and pathogenic micro…
ISO/ASTM51431-05
ОтменёнStandard Practice for Dosimetry in Electron Beam and X-Ray (Bremsstrahlung) Irradiation Facilities for Food P…
Significance and Use4.1 Food products may be treated with acceleratorgenerated radiation (electrons and X-rays) for numerous purposes, including control of parasites and pathogenic microorganisms, in…
ISO/ASTM52628-20e1
ДействующийStandard Practice for Dosimetry in Radiation Processing
1.1 This practice describes the basic requirements that apply when making absorbed dose measurements in accordance with the ASTM E61 series of dosimetry standards. In addition, it provides guidance o…
ISO/ASTM52921-13(2019)
ДействующийStandard Terminology for Additive Manufacturing—Coordinate Systems and Test Methodologies
Significance and Use 3.1 Although many additive manufacturing systems are based heavily upon the principles of Computer Numerical Control (CNC), the coordinate systems and nomenclature specific to CN…
ISO/ASTMTR52917-EB
ДействующийAdditive Manufacturing — Round Robin Testing — General Guidelines
This document outlines the steps with regard to aspects of design to conduct and run a round robin study (RRS) to assess the degree of variability in an additive manufacturing material or process. Th…
ISO/ASTM52901-17(2023)
ДействующийStandard Guide for Additive Manufacturing – General Principles – Requirements for Purchased AM Parts
Scope 1.1 This document defines and specifies requirements for purchased parts made by additive manufacturing. 1.2 It gives guidelines for the elements to be exchanged between the customer and the pa…