ISO 7886-1:2017 specifies requirements and test methods for verifying the design of empty sterile single-use hypodermic syringes, with or without needle, made of plastic or other materials and intended for the aspiration and injection of fluids after filling by the end-users. This document does not provide requirements for lot release. The syringes are primarily for use in humans. Sterile syringes specified in this document are intended for use immediately after filling and are not intended to contain the medicament for extended periods of time. It excludes syringes for use with insulin (see ISO 8537), single-use syringes made of glass, syringes for use with power-driven syringe pumps, syringes pre-filled by the manufacturer, and syringes intended to be stored after filling (e.g. in a kit for filling by a pharmacist). Hypodermic syringes without a needle specified in this document are intended for use with hypodermic needles specified in ISO 7864.
Abstract
Overview
ISO 7886-1:2017 - Sterile hypodermic syringes for single use - Part 1: Syringes for manual use - specifies performance requirements and test methods to verify the design of empty, sterile, single-use hypodermic syringes (with or without needles) intended for manual aspiration and injection after filling by the end user. The standard is performance‑based, focused on design verification rather than lot release, and applies primarily to syringes for human use that are intended to be used immediately after filling.
Key topics and technical requirements
The standard covers essential design and test topics, including:
- General requirements for syringe design, manufacture and sterilization practices.
- Materials and compatibility guidance (materials are not prescriptively specified; manufacturers must ensure compatibility with intended injection fluids).
- Graduated scale and tolerance - requirements for markings, scale position and capacity tolerances.
- Barrel, nozzle and plunger design - dimensional, fit and performance expectations for barrels, flanges, nozzles (including conical fittings) and plunger/plunger stopper assemblies.
- Performance tests such as:
- Dead space determination (residual volume after injection).
- Air and liquid leakage tests (air leakage during aspiration, liquid leakage under compression).
- Force to operate the piston (operational force limits and test method).
- Freedom from separation of plunger components and fit in barrel.
- Lubricant and silicone: guidance on lubrication, and informative test for silicone quantity.
- Packaging and labelling: unit, multiple‑unit and user packaging requirements, information supplied by the manufacturer, and specifics for self‑contained syringe units.
- Normative and informative annexes providing test methods: extract preparation, leakage tests, dead space method, piston force method, silicone quantity and related procedures.
Applications and who uses it
ISO 7886-1 is used by:
- Medical device manufacturers designing and validating single‑use sterile syringes.
- Quality and regulatory teams preparing technical files and ensuring compliance with international performance requirements.
- Test laboratories performing design verification and performance testing.
- Procurement and clinical engineers assessing syringe specifications for hospitals and clinics.
- Regulatory agencies and auditors reviewing conformity and usability considerations.
This part excludes insulin syringes (see ISO 8537), glass syringes, syringes for syringe pumps, manufacturer pre‑filled syringes, and syringes intended for long‑term storage. Hypodermic needles referenced conform to ISO 7864.
Related standards
- ISO 8537 - insulin syringes
- ISO 7864 - sterile hypodermic needles for single use
- ISO 13485 / ISO 9001 - quality management for medical devices
Keywords: ISO 7886-1:2017, sterile hypodermic syringes, single-use syringes, test methods, dead space, plunger stopper, graduated scale, medical device standards.
Технические детали
- Технический комитет
- ISO/TC 84 - Devices for administration of medicinal products and catheters
- SKU
- ISO 7886-1:2017
Похожие стандарты
Стандарты, упомянутые в описании
SIST EN ISO 7886-1:2018
ДействующийSterile hypodermic syringes for single use - Part 1: Syringes for manual use (ISO 7886-1:2017, Corrected vers…
Overview EN ISO 7886-1:2018 - Sterile hypodermic syringes for single use - Part 1: Syringes for manual use (ISO 7886-1:2017, corrected 2019‑08) is a CEN-adopted standard that specifies design require…
SIST EN ISO 8537:2016
ДействующийSterile single-use syringes, with or without needle, for insulin (ISO 8537:2016)
Overview EN ISO 8537:2016 - Sterile single-use syringes, with or without needle, for insulin (ISO 8537:2016) specifies requirements and test methods for empty, sterile, single‑use plastic insulin syr…
SIST EN ISO 7864:2016
ДействующийSterile hypodermic needles for single use - Requirements and test methods (ISO 7864:2016)
Overview SIST EN ISO 7864:2016 specifies international requirements and test methods for sterile hypodermic needles intended for single use, covering metric sizes from 0.18 mm to 1.2 mm. This standar…
SIST EN ISO 13485:2016/A11:2021
ДействующийMedical devices - Quality management systems - Requirements for regulatory purposes (ISO 13485:2016)
Overview EN ISO 13485:2016/A11:2021 is the European amendment (A11) to the international standard ISO 13485:2016 specifying quality management system (QMS) requirements for medical devices. Prepared…
ISO 19443:2018/Amd 1:2024
ДействующийQuality management systems — Specific requirements for the application of ISO 9001:2015 by organizations in t…
Overview ISO 19443:2018/Amd 1:2024 is an important amendment to the ISO 19443:2018 standard, which specifies quality management system requirements tailored for organizations within the supply chain…