ISO 7981-2:2005 PDF
Water quality — Determination of polycyclic aromatic hydrocarbons (PAH) — Part 2: Determination of six PAH by high-performance liquid chromatography with fluorescence detection after liquid-liquid extraction
Water quality — Determination of polycyclic aromatic hydrocarbons (PAH) — Part 2: Determination of six PAH by high-performance liquid chromatography with fluorescence detection after liquid-liquid extraction
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 23
- Дата публикации:
- 27 июня 2005 г.
- Издание:
- ISO IS 7981 edition 1 version 1
- ICS:
- 13.060.50
ISO 7981-2:2005 specifies the determination of six selected PAH in drinking, mineral and table waters and ground and surface waters in mass concentrations above 0,005 micrograms per litre, by high-performance liquid chromatography with fluorescence detection after liquid-liquid extraction. The six PAH are: fluoranthene, benzo[b]fluoranthene, benzo[a]pyrene, benzo[k]fluoranthene, indeno[1,2,3-cd]pyrene, and benzo[ghi]perylene. With some modification, this method is also applicable for the analysis of moderately polluted waste waters.
Abstract
Overview
ISO 7981-2:2005 specifies a laboratory method for determining six priority polycyclic aromatic hydrocarbons (PAH) in water using liquid–liquid extraction (LLE) followed by high-performance liquid chromatography (HPLC) with fluorescence detection. The procedure targets mass concentrations above 0.005 µg/L and is intended for drinking, mineral and table waters, groundwater and surface waters. With modifications it can also be applied to moderately polluted waste waters.
Key PAHs covered:
- Fluoranthene
- Benzo[b]fluoranthene
- Benzo[a]pyrene
- Benzo[k]fluoranthene
- Indeno[1,2,3-cd]pyrene
- Benzo[ghi]perylene
Keywords: ISO 7981-2:2005, water quality, PAH determination, HPLC fluorescence, liquid-liquid extraction, benzo[a]pyrene.
Key Topics and Technical Requirements
- Sampling and sample handling: Whole-sample analysis is specified because PAHs adsorb to particulates; avoid plastics and light exposure; follow good laboratory practice.
- Extraction and cleanup: PAHs are extracted by LLE using solvents such as cyclohexane, hexane or dichloromethane; extracts are concentrated by evaporation and, for surface/contaminated samples, cleaned on silica.
- Chromatography and detection: Separation by HPLC (isocratic conditions) with fluorescence detection using fixed excitation/emission settings; identification and quantification via retention times and fluorescence response.
- Calibration and quality control: Use certified single- and multi-substance stock solutions and prepare at least five calibration levels; perform blank measurements and determine recovery to validate results.
- Reagents and apparatus: Specifies HPLC-grade solvents (methanol, acetonitrile, tetrahydrofuran) and laboratory equipment (autosampler vials, silica cartridges, degassing assembly, fluorescence detector, temperature-controlled column).
- Safety and interferences: Notes carcinogenicity of some PAHs and hazards of solvents (e.g., acetonitrile, hexane); warns about fluorescent interferences and peak co-elution.
- Performance and reporting: Clauses cover calculation, expression of results and method accuracy (statistical evaluation referenced to ISO 8466-1).
Applications and Practical Use
- Routine monitoring of drinking water quality for regulatory compliance and public health protection.
- Environmental surveillance of surface water and groundwater for contamination by combustion-derived PAHs.
- Source-water and treatment-plant monitoring by water utilities, environmental laboratories and consultants.
- Screening of moderately polluted industrial or municipal wastewaters after method adjustments.
Who Would Use This Standard
- Accredited environmental testing laboratories
- Water utilities and treatment operators
- Environmental regulators and public health agencies
- Consultants performing watershed and pollution assessments
Related Standards
- ISO 7981-1 (Part 1 - HPTLC option)
- ISO 8466-1 (calibration and statistical evaluation)
- ISO 5667-2 / ISO 5667-3 (sampling guidance)
ISO 7981-2:2005 is a practical, well-defined method for reliable PAH quantification in water using HPLC-fluorescence and is suited to labs implementing routine monitoring and regulatory compliance programs.
Технические детали
- Технический комитет
- ISO/TC 147/SC 2 - Physical, chemical and biochemical methods
- SKU
- ISO 7981-2:2005
Похожие стандарты
Стандарты, упомянутые в описании
BS ISO 8466-1:2021
ДействующийWater quality. Calibration and evaluation of analytical methods - Linear calibration function
1 Scope This document specifies various calibration strategies for physicochemical and chemical analytical methods and specifies the calculation of analytical results. It defines the general context…
SIST ISO 7981-1:2007
ДействующийWater quality -- Determination of polycyclic aromatic hydrocarbons (PAH) -- Part 1: Determination of six PAH…
Overview ISO 7981-1:2005 - "Water quality - Determination of polycyclic aromatic hydrocarbons (PAH) - Part 1" specifies a laboratory method to determine six priority PAH in drinking water. The method…
BS ISO 5667-21:2010
ДействующийWater quality. Sampling - Guidance on sampling of drinking water distributed by tankers or means other than d…
BS ISO 5667-21:2010 Water quality. Sampling. Guidance on sampling of drinking water distributed by tankers or means other than distribution pipes This part of BS ISO 5667 establishes principles to be…
ISO 5667-3:2024
ДействующийWater quality — Sampling — Part 3: Preservation and handling of water samples
Overview ISO 5667-3:2024 - Water quality - Sampling - Part 3: Preservation and handling of water samples is the sixth edition of the ISO guidance on how to preserve, handle, transport and store water…