ISO 8596:2017 PDF
Ophthalmic optics — Visual acuity testing — Standard and clinical optotypes and their presentation
Ophthalmic optics — Visual acuity testing — Standard and clinical optotypes and their presentation
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 10
- Дата публикации:
- 28 ноября 2017 г.
- Издание:
- ISO IS 8596 edition 3 version 1
- ICS:
- 11.040.70
ISO 8596:2017 specifies a range of Landolt ring optotypes and describes a method for measuring distance visual acuity under photopic conditions for the purposes of certification or licensing. ISO 8596:2017 is neither intended as a standard for clinical measurements nor for the certification of blindness or partial sight. Other optotypes used for clinical investigations are described in Annex A for information.
Abstract
Overview
ISO 8596:2017, "Ophthalmic optics - Visual acuity testing - Standard and clinical optotypes and their presentation," defines the standard optotype (Landolt ring) and a method for measuring distance visual acuity under photopic conditions for purposes such as certification or licensing. It is not intended as a clinical measurement standard for diagnosing blindness or partial sight. Annex A provides information on other clinical optotypes for investigative use.
Key topics and technical requirements
- Standard optotype: Specifies the Landolt ring geometry (outer diameter, limb width and gap) and eight gap orientations (horizontal, vertical, four diagonals).
- Visual acuity scales: Supports decimal visual acuity, Snellen fraction, and LogMAR; defines corresponding visual acuity grades (see Table 1 of the standard).
- Optotype sizing and progression: Gap sizes follow a logarithmic progression with a size ratio of 10^(1/10) ≈ 1.2589 (ISO series R10).
- Presentation and spacing: Minimum spacing rules between optotypes depend on acuity grade; test field must extend ≥0.5° around optotypes and background must be uniform to avoid orientation cues.
- Luminance requirements: Surround (chart background) luminance between 80–320 cd/m² (recommended 200 cd/m²); optotype luminance not more than 15% of surround when measured in a darkened room; limits on luminance variability and glare.
- Viewing distance: Minimum 4.0 m between subject entrance pupil and optotype for distance testing.
- Test procedures and pass criteria: Preferred presentations are 5 or 10 optotypes per size; “Pass” requires at least 3/5 or 6/10 correct. Rules for termination and assignment of the visual acuity grade are specified.
- Quality and reporting: Optotypes must have sharply defined contours and consistent contrast. Test reports must reference ISO 8596:2017 and include instrument, acuity grades used, viewing distance, assigned grade, examiner, date and location.
Applications and users
ISO 8596:2017 is used by:
- Certification and licensing authorities (driver licensing, occupational fitness)
- Manufacturers of vision testing charts and automated visual acuity instruments
- Metrology and conformity assessment bodies validating instrument presentation quality
- Researchers comparing optotypes (use Annex A and ISO/TR 19498 for correlation to the Landolt ring)
The standard ensures reproducible, comparable distance visual acuity measurements for regulatory and certification purposes and provides technical requirements for chart design, presentation, luminance control, and reporting.
Related standards
- ISO/TR 19498 - guidance on correlating clinical optotypes to the standard optotype
- ISO 3:1973 - preferred numbers (series R10) used for optotype size progression
- ISO/IEC Directives - editorial and development procedures referenced by ISO documents
Keywords: ISO 8596:2017, visual acuity testing, Landolt ring, ophthalmic optics, standard optotype, distance visual acuity, Snellen, LogMAR, luminance, clinical optotypes.
Технические детали
- Технический комитет
- ISO/TC 172/SC 7 - Ophthalmic optics and instruments
- SKU
- ISO 8596:2017
Похожие стандарты
Упомянутые в описании и другие стандарты ISO
ISO 3:1973
ДействующийPreferred numbers — Series of preferred numbers
Overview ISO 3:1973, titled Preferred numbers - Series of preferred numbers, is an international standard established by the International Organization for Standardization (ISO). Published in 1973, t…
PD ISO/TR 19498:2015
ДействующийOphthalmic optics and instruments. Correlation of optotypes
1 Scope This Technical Report specifies a method of correlation between a given set of optotypes and the standard optotype (Landolt ring) formed and presented as specified in ISO 8596. All test metho…
ISO 8689-1:2000
ДействующийWater quality — Biological classification of rivers — Part 1: Guidance on the interpretation of biological qu…
Overview ISO 8689-1:2000, titled Water quality - Biological classification of rivers - Part 1: Guidance on the interpretation of biological quality data from surveys of benthic macroinvertebrates, is…
ISO/ASTM51540-04(2012)
ОтменёнStandard Practice for Use of a Radiochromic Liquid Dosimetry System (Withdrawn 2020)
Significance and Use4.1 The radiochromic liquid dosimetry system provides a means of measuring absorbed dose in materials (5-7). Under the influence of ionizing radiation, chemical reactions take pla…
ISO/ASTM51204-04
ДействующийStandard Practice for Dosimetry in Gamma Irradiation Facilities for Food Processing (Withdrawn 2013)
Significance and Use4.1 Food products may be treated with ionizing radiation, such as gamma-rays from 60Co or 137Cs sources, for numerous purposes, including control of parasites and pathogenic micro…
ISO/ASTM51431-05
ОтменёнStandard Practice for Dosimetry in Electron Beam and X-Ray (Bremsstrahlung) Irradiation Facilities for Food P…
Significance and Use4.1 Food products may be treated with acceleratorgenerated radiation (electrons and X-rays) for numerous purposes, including control of parasites and pathogenic microorganisms, in…
ISO/ASTM52628-20e1
ДействующийStandard Practice for Dosimetry in Radiation Processing
1.1 This practice describes the basic requirements that apply when making absorbed dose measurements in accordance with the ASTM E61 series of dosimetry standards. In addition, it provides guidance o…
ISO/ASTM52921-13(2019)
ДействующийStandard Terminology for Additive Manufacturing—Coordinate Systems and Test Methodologies
Significance and Use 3.1 Although many additive manufacturing systems are based heavily upon the principles of Computer Numerical Control (CNC), the coordinate systems and nomenclature specific to CN…