Is limited to vehicles with nominal 12 V supply voltage. Describes a subset of ISO 9141:1989. Specifies the requirements for setting-up the interchange of digital information between on-board emission-related electronic control units of road vehicles and the SAE OBD II scan tool as specified in SAE J1978. This communication is established to facilitate compliance with California Code of Regulation, Title 13, 1968.1.
Abstract
Overview
ISO 9141-2:1994 - "Road vehicles - Diagnostic systems - Part 2: CARB requirements for interchange of digital information" defines a CARB-focused subset of ISO 9141 for on‑board diagnostic communication between vehicle ECUs and an SAE OBD II scan tool. It is limited to nominal 12 V vehicle systems and was published to facilitate compliance with California Code of Regulation, Title 13, §1968.1 (malfunction and diagnostic systems requirements). The standard specifies initialization, header formats, signal levels, timing, and electrical limits needed for reliable exchange of emission‑related diagnostic data.
Key topics and technical requirements
- Scope & compatibility
- Subset of ISO 9141:1989 targeted at OBD II communication with SAE J1978 scan tools.
- Connector compatibility per SAE J1962.
- Physical lines
- Supports either one‑wire (K line) or two‑wire (K and L lines) configurations.
- K line: bidirectional after initialization; used for request/response messages.
- L line: unidirectional during initialization only; otherwise idles at logic “1”.
- Initialization & header
- Diagnostic tester transmits a 5‑bit/s address (standard address 0x33) to invoke the protocol.
- Initialization includes speed synchronization, two key words, logic inversions for handshaking and configurable P2 response intervals.
- Signal & timing
- Logic thresholds: transmitter logic “0” < 20% VB, logic “1” > 80% VB (receivers slightly different: 30%/70% VB).
- Bit coding: NRZ, slope time limits and sampling tolerances defined.
- Communication baud after init: 10.4 kbit/s ±1%.
- Key timing windows W0–W4 and P2 intervals specified (see Annex A in the standard).
- Electrical limits
- Diagnostic tester cable capacitance CTE ≤ 2 nF; vehicle line capacitance Cosw ≤ 2 nF; total bus CEcu + Cobw
Технические детали
- Технический комитет
- ISO/TC 22/SC 31 - Data communication
- SKU
- ISO 9141-2:1994
Похожие стандарты
Упомянутые в описании и другие стандарты ISO
ISO 9141:1989
ДействующийRoad vehicles — Diagnostic systems — Requirements for interchange of digital information
Overview ISO 9141:1989 - "Road vehicles - Diagnostic systems - Requirements for interchange of digital information" defines the electrical and protocol requirements for serial diagnostic communicatio…
ISO 9141-2:1994/Amd 1:1996
ДействующийRoad vehicles — Diagnostic systems — Part 2: CARB requirements for interchange of digital information — Amend…
Overview ISO 9141-2:1994/Amd 1:1996 is an international standard amendment that focuses on road vehicle diagnostic systems. Specifically, it details the CARB (California Air Resources Board) requirem…
ISO 8689-1:2000
ДействующийWater quality — Biological classification of rivers — Part 1: Guidance on the interpretation of biological qu…
Overview ISO 8689-1:2000, titled Water quality - Biological classification of rivers - Part 1: Guidance on the interpretation of biological quality data from surveys of benthic macroinvertebrates, is…
ISO/ASTM51540-04(2012)
ОтменёнStandard Practice for Use of a Radiochromic Liquid Dosimetry System (Withdrawn 2020)
Significance and Use4.1 The radiochromic liquid dosimetry system provides a means of measuring absorbed dose in materials (5-7). Under the influence of ionizing radiation, chemical reactions take pla…
ISO/ASTM51204-04
ДействующийStandard Practice for Dosimetry in Gamma Irradiation Facilities for Food Processing (Withdrawn 2013)
Significance and Use4.1 Food products may be treated with ionizing radiation, such as gamma-rays from 60Co or 137Cs sources, for numerous purposes, including control of parasites and pathogenic micro…
ISO/ASTM51431-05
ОтменёнStandard Practice for Dosimetry in Electron Beam and X-Ray (Bremsstrahlung) Irradiation Facilities for Food P…
Significance and Use4.1 Food products may be treated with acceleratorgenerated radiation (electrons and X-rays) for numerous purposes, including control of parasites and pathogenic microorganisms, in…
ISO/ASTM52628-20e1
ДействующийStandard Practice for Dosimetry in Radiation Processing
1.1 This practice describes the basic requirements that apply when making absorbed dose measurements in accordance with the ASTM E61 series of dosimetry standards. In addition, it provides guidance o…
ISO/ASTM52921-13(2019)
ДействующийStandard Terminology for Additive Manufacturing—Coordinate Systems and Test Methodologies
Significance and Use 3.1 Although many additive manufacturing systems are based heavily upon the principles of Computer Numerical Control (CNC), the coordinate systems and nomenclature specific to CN…