ISO/IEC 29109-8:2011 PDF
Information technology — Conformance testing methodology for biometric data interchange formats defined in ISO/IEC 19794 — Part 8: Finger pattern skeletal data
Information technology — Conformance testing methodology for biometric data interchange formats defined in ISO/IEC 19794 — Part 8: Finger pattern skeletal data
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 20
- Дата публикации:
- 15 декабря 2011 г.
- Издание:
- ISO/IEC IS 29109 edition 1 version 1
- ICS:
- 35.040
ISO/IEC 29109-8:2011 specifies elements of conformance testing methodology, test assertions, and test procedures as applicable to ISO/IEC 19794-8:2006. It establishes test assertions of the structure of the finger pattern skeletal data format as specified in ISO/IEC 19794-8:2006 (Type A Level 1 as defined in ISO/IEC 29109-1:2009), test asssertions of internal consistency by checking the types of values that may be contained within each field (Type A Level 2 as defined in ISO/IEC 29109-1:2009). It does not establish test of conformance of Common Biometric Exchange Formats Framework (CBEFF) structures required by ISO/IEC 19794-8:2006, test of consistency with input biometric data record (Level 3), test of other characteristics of biometric products or other types of testing of biometric products (e.g. acceptance, performance, robustness, security), test of conformance of systems that do not produce ISO/IEC 19794-8:2006 records.
Abstract
Overview
ISO/IEC 29109-8:2011 defines a conformance testing methodology for biometric data interchange records that use the finger pattern skeletal data format specified in ISO/IEC 19794-8:2006. It provides the test assertions and test procedures (Type A Level 1 and Level 2) needed to verify the structure and internal consistency of ISO/IEC 19794-8 records. The standard adopts the generalized testing approach in ISO/IEC 29109-1:2009 (Clauses 6–8) but explicitly excludes tests of CBEFF structures, Level 3 consistency with input biometric data, and other product-level evaluations (performance, security, robustness).
Key topics and requirements
- Scope of testing: Focused on binary record correctness - structural conformance (Level 1) and internal consistency/value checks (Level 2) for finger pattern skeletal data.
- Adopted methodology: Uses the conformance testing framework and procedures set out in ISO/IEC 29109-1:2009.
- Test assertions: Tables of test assertions map ISO/IEC 19794-8 requirements to Level 1/2 tests; examples include:
- Minutiae definitions and types (ridge ending, bifurcation) and their encoding.
- Coordinate system and metric resolution for minutiae positions.
- Skeleton line encoding rules (start points, topology preservation, virtual continuations).
- Record and header fields (format identifier “FSK\0”, version number, record length, reserved bits and device/capture metadata).
- Finger headers, view numbering and uniqueness rules for multiple records of the same finger.
- Excluded tests: No CBEFF structure conformance, no Level 3 (consistency with source biometric data), and no acceptance/performance/robustness/security testing.
Practical applications
- Ensuring interoperability between biometric systems that exchange finger pattern skeletal records.
- Building conformance test suites and automated test tools to validate ISO/IEC 19794-8 record encoders/decoders.
- Supporting certification and compliance programs for vendors that claim conformance to ISO/IEC 19794-8.
- Guiding developers and QA teams in producing correct finger pattern skeletal data for integration into Common Biometric Exchange Formats Framework (CBEFF)-aware systems.
Who should use it
- Conformance testing laboratories and certification bodies
- Biometric product vendors (implementing ISO/IEC 19794-8 encoders/decoders)
- System integrators and developers of biometric middleware
- Standards and compliance engineers designing interoperability test suites
Related standards
- ISO/IEC 19794-8:2006 - Biometric data interchange format: Finger pattern skeletal data (base standard)
- ISO/IEC 29109-1:2009 - Generalized conformance testing methodology for ISO/IEC 19794 formats
- Other ISO/IEC 29109 parts addressing fingerprints, face, iris, signature, vascular, etc.
Keywords: ISO/IEC 29109-8:2011, conformance testing, biometric data interchange, ISO/IEC 19794-8, finger pattern skeletal data, CBEFF, test assertions, interoperability.
Технические детали
- Технический комитет
- ISO/IEC JTC 1/SC 37 - Biometrics
- SKU
- ISO/IEC 29109-8:2011
Похожие стандарты
Упомянутые в описании и другие стандарты ISO
ISO/IEC 19794-8:2011/Amd 1:2014
ДействующийInformation technology — Biometric data interchange formats — Part 8: Finger pattern skeletal data — Amendmen…
Overview ISO/IEC 19794-8:2011/Amd 1:2014 is an amendment to the international biometric standard for finger pattern skeletal data. It adds a normative conformance testing methodology (Annex A) for th…
BS ISO/IEC 29109-10:2010
ДействующийInformation technology. Conformance testing methodology for biometric data interchange formats defined in ISO…
ISO 8689-1:2000
ДействующийWater quality — Biological classification of rivers — Part 1: Guidance on the interpretation of biological qu…
Overview ISO 8689-1:2000, titled Water quality - Biological classification of rivers - Part 1: Guidance on the interpretation of biological quality data from surveys of benthic macroinvertebrates, is…
ISO/ASTM51540-04(2012)
ОтменёнStandard Practice for Use of a Radiochromic Liquid Dosimetry System (Withdrawn 2020)
Significance and Use4.1 The radiochromic liquid dosimetry system provides a means of measuring absorbed dose in materials (5-7). Under the influence of ionizing radiation, chemical reactions take pla…
ISO/ASTM51204-04
ДействующийStandard Practice for Dosimetry in Gamma Irradiation Facilities for Food Processing (Withdrawn 2013)
Significance and Use4.1 Food products may be treated with ionizing radiation, such as gamma-rays from 60Co or 137Cs sources, for numerous purposes, including control of parasites and pathogenic micro…
ISO/ASTM51431-05
ОтменёнStandard Practice for Dosimetry in Electron Beam and X-Ray (Bremsstrahlung) Irradiation Facilities for Food P…
Significance and Use4.1 Food products may be treated with acceleratorgenerated radiation (electrons and X-rays) for numerous purposes, including control of parasites and pathogenic microorganisms, in…
ISO/ASTM52628-20e1
ДействующийStandard Practice for Dosimetry in Radiation Processing
1.1 This practice describes the basic requirements that apply when making absorbed dose measurements in accordance with the ASTM E61 series of dosimetry standards. In addition, it provides guidance o…
ISO/ASTM52921-13(2019)
ДействующийStandard Terminology for Additive Manufacturing—Coordinate Systems and Test Methodologies
Significance and Use 3.1 Although many additive manufacturing systems are based heavily upon the principles of Computer Numerical Control (CNC), the coordinate systems and nomenclature specific to CN…