ISO/PAS 18999:2024 PDF
Healthcare organization management — Pandemic response —Guidelines for respiratory infection prevention and control in hospitals
Healthcare organization management — Pandemic response —Guidelines for respiratory infection prevention and control in hospitals
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 28
- Дата публикации:
- 29 января 2024 г.
- Издание:
- ISO PAS 18999 edition 1 version 1
- ICS:
- 11.020.01
This document provides guidelines to prevent cross-infections within a hospital, with a specific focus on the separate operation of wards dedicated to highly contagious respiratory infectious diseases, transportation of confirmed cases of highly contagious respiratory infectious diseases, disinfection, waste management, etc. This document applies to the following: a) separate operation of wards dedicated to highly contagious respiratory infectious diseases; b) transportation of confirmed cases of highly contagious respiratory infectious diseases and roles of the dedicated healthcare team in a ward dedicated to highly contagious respiratory infectious diseases; c) cleaning, disinfection, and waste management.
Abstract
Overview
ISO/PAS 18999:2024 - Healthcare organization management - Pandemic response - Guidelines for respiratory infection prevention and control in hospitals provides practical, hospital-focused guidance to prevent cross‑infections during outbreaks of highly contagious respiratory diseases. The Publicly Available Specification concentrates on three core areas: separate operation of wards for respiratory infectious diseases, safe transportation of confirmed cases (and roles of dedicated teams), and cleaning, disinfection and medical waste management.
Keywords: ISO/PAS 18999:2024, pandemic response, respiratory infection prevention, hospital infection control, isolation wards
Key topics and technical requirements
- Separate ward operation
- Operate dedicated wards to prevent transmission to other patients and staff.
- Prefer single‑occupancy negative pressure rooms; when unavailable, follow staged room‑assignment priorities to maintain separation.
- HVAC/AHU guidance: shift from default mixed-air operation (example in the document: 30% outside / 70% recirculated) to 100% outside air supply and 100% exhaust where possible; in resource-limited settings, open windows ≥3 times daily for >30 minutes.
- Prioritize negative‑pressure rooms for high‑risk patients (e.g., oxygen saturation