PD IEC/TR 62343-6-6:2017 PDF
Dynamic modules - Design guide. Failure mode effect analysis for optical units of dynamic modules
Dynamic modules - Design guide. Failure mode effect analysis for optical units of dynamic modules
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Дата публикации:
- 6 января 2017 г.
- ICS:
- 33.180.20
- SKU:
- PD IEC/TR 62343-6-6:2017
Abstract
What is PD IEC/TR 62343-6-6 - Guidance for failure mode effect analysis module about?
Failure mode effect analysis is one of the effective and useful analysis methods to determine the reliability evaluation test items and conditions that are defined in future reliability qualification documents. PD IEC/TR 62343-6-6 is an international standard that focuses on dynamic modules and provide guidance for failure mode effect analysis with optical units of dynamic modules. PD IEC/TR 62343-6-6 describes the dominant failure mode for dynamic modules and relevant tests from IEC 61300-2 . To estimate the lifetime for a module, there is a typical procedure. The first step is to identify the dominant failure modes. The second step is to determine the acceleration tests according to these failure modes. The third step is to carry out the test. The fourth step is to estimate the acceleration factors. Finally, the fifth step is to calculate the lifetime of the dynamic module.
Who is PD IEC/TR 62343-6-6 - Guidance for failure mode effect analysis module for?
PD IEC/TR 62343-6-6 on dynamic modules and guidelines for failure mode effect analysis is useful for:
Electrical engineers Professional technicians who involved in circuit integrity Network eng...