SIST EN ISO 10993-23:2021 PDF
Biological evaluation of medical devices - Part 23: Tests for irritation (ISO 10993-23:2021)
Biological evaluation of medical devices - Part 23: Tests for irritation (ISO 10993-23:2021)
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 76
- Дата публикации:
- 25 мая 2021 г.
- ICS:
- 11.100.20
- Технический комитет:
- VAZ - Healthcare
This document specifies the procedure for the assessment of medical devices and their constituent materials with regard to their potential to produce irritation. The tests are designed to predict and classify the irritation potential of medical devices, materials or their extracts according to ISO 10993‑1 and ISO 10993‑2. This document includes: — pre-test considerations for irritation, including in silico and in vitro methods for dermal exposure; — details of in vitro and in vivo irritation test procedures; — key factors for the interpretation of the results.
Abstract
Overview
SIST EN ISO 10993-23:2021 - "Biological evaluation of medical devices - Part 23: Tests for irritation (ISO 10993-23:2021)" defines procedures to assess a medical device’s potential to cause irritation. The standard is part of the ISO 10993 series on biological evaluation and is used to predict and classify irritation potential of devices, constituent materials or extracts in accordance with ISO 10993‑1 and ISO 10993‑2. It covers pre-test considerations, both non-animal and animal-based test methods, and guidance for interpreting results.
Key Topics and Technical Requirements
- Scope and purpose: Procedures to assess irritation potential for contact routes (notably dermal exposure) and to support risk management decisions.
- Pre-test considerations: Emphasis on a tiered approach that includes in silico (computational) and in vitro methods where appropriate to minimize animal testing.
- In vitro and in vivo test procedures: Describes standardized test workflows for laboratory testing of materials and extracts to evaluate irritation reactions. (The standard specifies detailed methods; laboratories should consult the full text.)
- Classification and prediction: Framework to classify irritation potential and to align results with the biological evaluation strategy in ISO 10993‑1 and ISO 10993‑2.
- Result interpretation: Key factors and contextual information to interpret outcomes, including exposure conditions, device function, duration of contact and clinical relevance.
Practical Applications and Who Uses This Standard
SIST EN ISO 10993-23 is designed for stakeholders involved in medical device safety and regulatory compliance:
- Medical device manufacturers - to design biocompatibility testing plans, select appropriate irritation tests, and document safety for regulatory submissions.
- Biocompatibility assessors & toxicologists - to interpret test data and integrate irritation findings into risk assessments.
- Testing laboratories (GLP/GMP) - to implement validated in vitro/in vivo test procedures for irritation testing.
- Regulatory and quality professionals / Notified bodies - to assess conformity with biological safety requirements and support claims under EU Regulation (EU) 2017/745 and related directives.
- R&D teams - to screen materials and formulations early in development for potential irritation hazards.
Related Standards and Regulatory Context
- Closely linked to ISO 10993‑1 (biological evaluation framework) and ISO 10993‑2 (animal welfare considerations).
- Cross-references other ISO 10993 parts (e.g., ISO 10993‑12 for sample preparation, ISO 10993‑18 for chemical characterization).
- Includes informative annexes mapping the standard to EU Directives and Regulation (EU) 2017/745 (MDR) to support conformity assessment.
This standard is essential for robust irritation testing, reducing animal use through alternative methods, and documenting compliance for safe medical device launch and post‑market surveillance.
Технические детали
- SKU
- SIST EN ISO 10993-23:2021
Похожие стандарты
Стандарты, упомянутые в описании
ISO 10993-23:2021
ДействующийBiological evaluation of medical devices — Part 23: Tests for irritation
Overview - ISO 10993-23:2021 (Tests for irritation) ISO 10993-23:2021 is part of the ISO 10993 series on the biological evaluation of medical devices. It specifies procedures to assess the potential…
BS EN ISO 10993-11:2018
ДействующийBiological evaluation of medical devices. Tests for systemic toxicity.
ISO 10993-2:2022
ДействующийBiological evaluation of medical devices — Part 2: Animal welfare requirements
Overview ISO 10993-2:2022 - "Biological evaluation of medical devices - Part 2: Animal welfare requirements" is the third edition (2022) in the ISO 10993 series. This standard specifies minimum anima…
SIST EN ISO 10993-23:2021/A1:2025
ДействующийBiological evaluation of medical devices - Part 23: Tests for irritation - Amendment 1: Additional in vitro r…
Overview EN ISO 10993-23:2021/A1:2025 is an amendment to ISO 10993-23:2021 - the part of the ISO 10993 series that specifies tests for irritation as part of the biological evaluation of medical devic…
SIST EN ISO 10993-1:2026
ДействующийBiological evaluation of medical devices - Part 1: Requirements and general principles for the evaluation of…
Overview SIST EN ISO 10993-1:2026 provides essential requirements and general principles for the biological evaluation of medical devices in the context of a risk management process. Developed by SIS…
ISO 10993-18:2020/Amd 1:2022
ДействующийBiological evaluation of medical devices — Part 18: Chemical characterization of medical device materials wit…
Overview ISO 10993-18:2020/Amd 1:2022 is an important amendment to the international standard for the biological evaluation of medical devices, specifically addressing the chemical characterization o…