ISO 12631:2017 specifies a method for calculating the thermal transmittance of curtain walls consisting of glazed and/or opaque panels fitted in, or connected to, frames. The calculation includes: - different types of glazing, e.g. glass or plastic; single or multiple glazing; with or without low emissivity coating; with cavities filled with air or other gases; - frames (of any material) with or without thermal breaks; - different types of opaque panels clad with metal, glass, ceramics or any other material. Thermal bridge effects at the rebate or connection between the glazed area, the frame area and the panel area are included in the calculation. The calculation does not include: - effects of solar radiation; - heat transfer caused by air leakage; - calculation of condensation; - effect of shutters; - additional heat transfer at the corners and edges of the curtain walling; - connections to the main building structure nor through fixing lugs; - curtain wall systems with integrated heating. NOTE Table 1 in the Introduction shows the relative position of ISO 12631:2017 within the set of EPB standards in the context of the modular structure as set out in ISO 52000-1.
Abstract
Overview
EN ISO 12631:2017 - Thermal performance of curtain walling - Calculation of thermal transmittance (ISO 12631:2017) specifies a standardized method to calculate the thermal transmittance (U-value) of curtain wall systems composed of glazed and/or opaque panels fitted in or connected to frames. Prepared by CEN in collaboration with ISO, this standard is part of the EPB (energy performance of buildings) set and supports consistent thermal performance assessment for façades used in building energy modelling, compliance and product development.
Key topics and technical requirements
- Scope of calculation
- Covers curtain wall components including: glazed units (glass or plastic; single/multiple panes; low-e coatings; gas-filled cavities), frames (any material, with/without thermal breaks), and opaque panels clad with metal, glass, ceramics or other materials.
- Includes thermal bridge effects at rebates and connections between glazed area, frame area and panel area.
- Explicit exclusions
- Effects of solar radiation, heat transfer due to air leakage, condensation calculations, shutters, extra heat transfer at curtain-wall corners/edges, connections to main building structure or fixing lugs, and systems with integrated heating.
- Methodologies
- Defines both a single assessment method and a component assessment method for calculating curtain wall transmittance, with prescribed input data, time intervals and reporting requirements.
- Inputs and outputs
- Specifies geometrical characteristics, thermal properties and boundary definitions required for calculation and result presentation.
- Annexes and detailed procedures
- Includes normative annexes (e.g., linear thermal transmittance of junctions, screw effects using ISO 10077-2 procedures, ventilated/unventilated air spaces) and templates for input and reporting.
Applications and who uses it
- Primary users
- Façade engineers, thermal analysts, architects, product designers, window and curtain wall manufacturers, energy assessors, and certification bodies.
- Practical uses
- Calculating a curtain wall’s U-value for building energy simulations, compliance with national energy codes and EPBD-related requirements, product development (optimizing glazing, frames, thermal breaks), tender documentation and third‑party certification.
- Benefits
- Provides a harmonized, reproducible method for comparing systems, quantifying thermal bridge effects at junctions, and integrating curtain wall performance into whole-building energy assessments.
Related standards
- ISO 52000-1 (context of EPB modular structure)
- ISO 10077-2 (referenced for 2D numerical screw-effect procedures)
- EN ISO 12631 supersedes EN ISO 12631:2012 and forms part of the EPB standards supporting EU Directive 2010/31/EU.
Keywords: EN ISO 12631:2017, thermal performance, curtain walling, thermal transmittance, U-value, glazing, frames, thermal bridge, EPB standards.
Технические детали
- SKU
- SIST EN ISO 12631:2017
Похожие стандарты
Стандарты, упомянутые в описании
ISO 12631:2017
ДействующийThermal performance of curtain walling — Calculation of thermal transmittance
Overview ISO 12631:2017 - Thermal performance of curtain walling - Calculation of thermal transmittance specifies a harmonized method to calculate the overall thermal transmittance (U‑value) of curta…
ISO 12631:2012
ОтменёнThermal performance of curtain walling — Calculation of thermal transmittance
SIST EN ISO 10077-2:2017/A1:2025
ДействующийThermal performance of windows, doors and shutters - Calculation of thermal transmittance - Part 2: Numerical…
Overview EN ISO 10077-2:2017/A1:2025 is Amendment 1 to ISO 10077-2:2017 - the internationally used method for calculating the thermal transmittance (U‑value) of window, door and shutter frames using…
SIST EN ISO 52000-1:2018
Energy performance of buildings - Overarching EPB assessment - Part 1: General framework and procedures (ISO…
Overview EN ISO 52000-1:2017 - "Energy performance of buildings - Overarching EPB assessment - Part 1: General framework and procedures" (CEN adoption of ISO 52000-1:2017) defines a systematic, modul…