SIST EN ISO 15586:2003 PDF
Water quality - Determination of trace elements using atomic absorption spectrometry with graphite furnace (ISO 15586:2003)
Water quality - Determination of trace elements using atomic absorption spectrometry with graphite furnace (ISO 15586:2003)
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 25
- Дата публикации:
- 1 декабря 2003 г.
- ICS:
- 13.060.50
- Технический комитет:
- KAV - Water quality
ISO 15586:2003 includes principles and procedures for the determination of trace levels of: Ag, Al, As, Cd, Co, Cr, Cu, Fe, Mn, Mo, Ni, Pb, Sb, Se, Tl, V, and Zn in surface water, ground water, drinking water, wastewater and sediments, using atomic absorption spectrometry with electrothermal atomization in a graphite furnace. The method is applicable to the determination of low concentrations of elements. The detection limit of the method for each element depends on the sample matrix as well as of the instrument, the type of atomizer and the use of chemical modifiers. For water samples with a simple matrix (i.e. low concentration of dissolved solids and particles), the method detection limits will be close to instrument detection limits. The minimum acceptable detection limit values for a 20-microlitre sample volume are specified.
Abstract
Overview
EN ISO 15586:2003 - Water quality: Determination of trace elements using atomic absorption spectrometry with graphite furnace specifies principles and procedures for measuring low concentrations of trace metals in water and sediments using atomic absorption spectrometry (AAS) with electrothermal atomization in a graphite furnace. The method covers 17 elements (Ag, Al, As, Cd, Co, Cr, Cu, Fe, Mn, Mo, Ni, Pb, Sb, Se, Tl, V and Zn) in surface water, groundwater, drinking water, wastewater and sediments. The standard defines sample preparation (preservation, filtration, digestion), measurement, calibration and reporting, and gives minimum acceptable detection limits for a 20 µl sample volume.
Key topics and technical requirements
- Analytes covered: Ag, Al, As, Cd, Co, Cr, Cu, Fe, Mn, Mo, Ni, Pb, Sb, Se, Tl, V, Zn.
- Technique: Electrothermal atomization (graphite furnace) AAS - small sample volumes (typical 20 µl) for trace measurements.
- Detection limits & working ranges: The standard specifies minimum detection limits for a 20 µl sample (e.g., Cd ≈ 0.1 µg/L, As ≈ 1 µg/L, Pb ≈ 1 µg/L, Zn ≈ 0.5 µg/L) and gives characteristic masses and optimum working ranges per element.
- Sample handling: Preservation by acidification, filtration, and digestion (including sediment digestion) when required. High‑purity reagents (Grade 1 water, concentrated HNO3/HCl) are mandated for preparation.
- Interferences & mitigation: Matrix effects (e.g., chloride volatility causing losses), spectral/background interferences; use of chemical modifiers, pyrolytic coatings, background correction (including Zeeman), optimized temperature programs and standard addition calibration are described.
- Quality control: Calibration, calculation, precision assessment, and reporting requirements are included. Annexes provide stock solution preparation, sediment digestion procedures, and example instrument settings.
Applications and users
EN ISO 15586:2003 is intended for:
- Environmental and water testing laboratories performing trace metals analysis.
- Regulatory agencies and compliance monitoring programs for drinking water and environmental quality.
- Water utilities, consultancy firms and researchers needing validated AAS graphite furnace methods for low‑level element determination. Practical uses include routine monitoring, pollution incident investigation, sediment contamination studies and baseline surveys.
Related standards
Normative references and complementary standards include:
- ISO 3696 (water for analytical use),
- ISO 5667 series (sampling guidance),
- ISO 15587 series (digestion methods).
EN ISO 15586:2003 provides a validated AAS graphite furnace protocol for reliable, low‑level trace element determination in water quality monitoring and sediment analysis.
Технические детали
- SKU
- SIST EN ISO 15586:2003
Похожие стандарты
Стандарты, упомянутые в описании
ISO 15586:2003
ДействующийWater quality — Determination of trace elements using atomic absorption spectrometry with graphite furnace
Overview ISO 15586:2003 - "Water quality - Determination of trace elements using atomic absorption spectrometry with graphite furnace" - specifies principles and procedures for measuring low (trace)…
SIST EN ISO 3696:1998
ДействующийWater for analytical laboratory use - Specification and test methods (ISO 3696:1987)
Overview EN ISO 3696:1995 (ISO 3696:1987) – "Water for analytical laboratory use – Specification and test methods" is a CEN-adopted international standard that defines quality grades, specification l…
BS ISO 5667-21:2010
ДействующийWater quality. Sampling - Guidance on sampling of drinking water distributed by tankers or means other than d…
BS ISO 5667-21:2010 Water quality. Sampling. Guidance on sampling of drinking water distributed by tankers or means other than distribution pipes This part of BS ISO 5667 establishes principles to be…
SIST EN ISO 15587-1:2003
ДействующийWater quality - Digestion for the determination of selected elements in water - Part 1: Aqua regia digestion…
Overview EN ISO 15587-1:2002 - "Water quality - Digestion for the determination of selected elements in water - Part 1: Aqua regia digestion" (CEN adoption of ISO 15587-1:2002) specifies a standardiz…