Indoor, ambient and workplace air - Sampling and analysis of volatile organic compounds by sorbent tube/thermal desorption/capillary gas chromatography - Part 2: Diffusive sampling (ISO 16017-2:2003)
Indoor, ambient and workplace air - Sampling and analysis of volatile organic compounds by sorbent tube/thermal desorption/capillary gas chromatography - Part 2: Diffusive sampling (ISO 16017-2:2003)
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 38
- Дата публикации:
- 1 ноября 2003 г.
- ICS:
- 13.040.01
- Технический комитет:
- KAZ - Air quality
ISO 16017-2:2003 gives general guidance for the sampling and analysis of volatile organic compounds (VOCs) in air. It is applicable to indoor, ambient and workplace air. ISO 16017-2:2003 is applicable to a wide range of VOCs, including hydrocarbons, halogenated hydrocarbons, ester, glycol ethers, ketones and alcohols. A number of sorbents are recommended for the sampling of these VOCs, each sorbent having a different range of applicability. Very polar compounds generally require derivatisation; very low boiling compounds are only partially retained by the sorbents and can only be estimated qualitatively. Semi-volatile compounds are fully retained by the sorbents, but may only be partially recovered. ISO 16017-2:2003 is applicable to the measurement of airborne vapours of VOCs in a concentration range of approximately 0,002 mg/m3 to 100 mg/m3 individual organic for an exposure time of 8 h, or 0,3 g/m3 to 300 g/m3 individual organic for an exposure time of four weeks. The upper limit of the useful range is set by the sorptive capacity of the sorbent used and by the linear dynamic range of the gas chromatograph column and detector or by the sample splitting capability of the analytical instrumentation used. The lower limit of the useful range depends on the noise level of the detector and on blank levels of analyte and/or interfering artefacts on the sorbent tubes. Artefacts are typically sub-nanogram for well-conditioned Tenax GR and carbonaceous sorbents, carbonized molecular sieves and pure charcoals; at low nanogram levels for Tenax TA and at 5 ng to 50 ng levels for other porous polymers.
Abstract
Overview
EN ISO 16017-2:2003 - Indoor, ambient and workplace air: Sampling and analysis of volatile organic compounds (VOCs) by sorbent tube / thermal desorption / capillary gas chromatography - Part 2: Diffusive sampling - provides practical guidance for diffusive (passive) sampling of VOCs in indoor, ambient and workplace air. The standard covers the sampling principle, sorbent selection and conditioning, calibration of uptake rates, thermal desorption and capillary GC analysis, and reporting/quality control for a broad range of organic vapours (hydrocarbons, halogenated hydrocarbons, esters, glycol ethers, ketones, alcohols).
Key topics and requirements
- Sampling principle: Use of diffusive (passive) samplers where vapours migrate by diffusion to a sorbent and are later thermally desorbed and analysed by capillary gas chromatography (typically with FID or other suitable detectors). Uptake rates must be calibrated in a standard atmosphere.
- Scope of VOCs: Applicable to many VOC classes; very polar compounds may require derivatisation, very low-boiling compounds are only partially retained (qualitative only), and semi-volatile compounds may be partially recovered.
- Concentration ranges: The document gives approximate usable ranges for common exposure times (examples in the standard include ranges for 8 h and for four-week exposures).
- Sorbents and conditioning: Recommends multiple sorbents (e.g., Tenax GR, Tenax TA, Carbopack/Carbotrap-type carbonaceous sorbents, Spherocarb, Chromosorbs, Porapaks); sorbents must be preconditioned (e.g., heated under inert gas) and handled to avoid contamination.
- Analytical limits and artefacts: Upper limits dictated by sorbent capacity and GC linearity; lower limits by detector noise and blank/artefact levels (typical artefact levels: sub-ng for Tenax GR and carbonaceous sorbents; low-ng for Tenax TA; 5–50 ng for other porous polymers).
- Quality assurance: Procedures for calibration (liquid/vapour spiking), desorption efficiency, uptake-rate calibration, interference checks, and documentation.
Applications and users
- Environmental and occupational hygiene monitoring programs (indoor air quality, workplace exposure assessments, ambient VOC surveys)
- Analytical laboratories performing thermal desorption–GC analysis
- Building consultants, industrial hygienists, regulatory bodies and researchers assessing VOC exposure and compliance
- Useful for long-term passive monitoring (weeks) and short-term exposure assessments (hours)
Related standards
- EN/ISO 16017-1 (Part 1: Pumped sampling)
- ISO 16000-1 (Indoor air - general sampling strategy)
- prEN 13528-3 (theory and performance of diffusive samplers)
Keywords: EN ISO 16017-2:2003, diffusive sampling, passive samplers, VOC sampling, sorbent tube, thermal desorption, capillary gas chromatography, indoor air, workplace air, sorbent selection, uptake rate calibration.
Технические детали
- SKU
- SIST EN ISO 16017-2:2003
Похожие стандарты
Стандарты, упомянутые в описании
ISO 16017-2:2003
ДействующийIndoor, ambient and workplace air — Sampling and analysis of volatile organic compounds by sorbent tube/therm…
Overview ISO 16017-2:2003 is an international standard published by ISO, providing general guidance for the sampling and analysis of volatile organic compounds (VOCs) in air using diffusive sampling…
SIST EN ISO 16017-1:2002
ДействующийIndoor, ambient and workplace air - Sampling and analysis of volatile organic compounds by sorbent tube/therm…
Overview EN ISO 16017-1:2000 provides guidance for the sampling and analysis of volatile organic compounds (VOCs) in indoor, ambient and workplace air using sorbent tubes, thermal desorption and capi…