SIST EN ISO 16720:2007 PDF
Soil quality - Pretreatment of samples by freeze-drying for subsequent analysis (ISO 16720:2005)
Soil quality - Pretreatment of samples by freeze-drying for subsequent analysis (ISO 16720:2005)
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 10
- Дата публикации:
- 17 августа 2007 г.
- ICS:
- 13.080.20
- Технический комитет:
- KAT - Soil quality
ISO 16720:2005 specifies a method for pretreatment of soil samples by freeze-drying for subsequent analysis. ISO 16720:2005 is applicable to soil samples for subsequent determination of elements or organic compounds recognized as non-volatile under freeze-drying conditions. Generally, ISO 16720:2005 can also be applied to samples from sludges and sediments. This method is also applicable as a first step for the determination of dry matter (or water) content, for instance in the case of samples with high water content.
Abstract
Overview
SIST EN ISO 16720:2007, titled Soil Quality - Pretreatment of Samples by Freeze-Drying for Subsequent Analysis (ISO 16720:2005), is a European and international standard developed by CEN and ISO. This standard specifies a standardized method for pretreating soil samples through freeze-drying, preparing them for precise and reliable subsequent chemical or physical analyses. It applies to soil samples, as well as sludge and sediment samples, particularly for the determination of non-volatile elements or organic compounds. The method also serves as an initial step for measuring dry matter or water content in samples with high moisture levels.
Freeze-drying, also known as lyophilization, removes water content by sublimating ice under vacuum conditions, preserving the sample's integrity for later testing. SIST EN ISO 16720:2007 ensures uniformity and reproducibility in sample preparation, a critical phase influencing the quality of analytical results.
Key Topics
-
Scope and Applicability Applicable to soils, sludges, and sediments for the determination of elements or organic compounds resistant to freeze-drying temperatures. Suitable for samples with high water content requiring dry matter or water content determination.
-
Freeze-Drying Principle Samples are pre-cooled below their eutectic points (generally below −40 °C) to freeze the material. Under vacuum, ice sublimates directly to vapor without passing through the liquid phase, ensuring sample constituents remain unchanged.
-
Apparatus and Equipment
- Freeze-drying chambers with temperature-controlled carriers or external inlet manifolds for sample flasks
- Vacuum systems maintaining pressures between 37 Pa to 63 Pa to prevent thawing
- Cooling condensers operated below −50 °C to capture sublimated water vapor
- Pre-cooling freezers and rotating systems for even and rapid sample freezing
- Appropriate sample containers ensuring sample thickness does not exceed 2 cm
-
Procedure and Sample Handling Samples are placed in containers with a thin layer to accelerate freezing and drying. Post drying, samples become pulverulent and require careful handling to minimize dust formation and loss. Samples may be stored in airtight containers, such as brown glass bottles, to prevent moisture reabsorption.
-
Dry Matter Content Determination The standard outlines calculations for partially dried samples and final dry matter content adjusted to standard drying at 105 °C, accounting for residual water absorbed during storage or handling.
-
Interferences & Limitations Volatile compounds may partially vaporize and be lost during freeze-drying, potentially impacting certain analytical results. For example, ammonia nitrogen may not be stable under these conditions. Therefore, exclusion or adjustment in analyses involving volatile compounds is necessary.
-
Documentation and Reporting Test reports must reference the standard, identify samples, document pretreatment, and note any deviations or influencing factors affecting results.
Applications
-
Soil Quality Assessment Pretreatment of soil samples by freeze-drying facilitates accurate determination of elemental and organic constituents without alteration by heat or moisture.
-
Environmental Monitoring Applicable to sludge and sediment samples for monitoring pollution levels, nutrient content, or contaminant characterization while preserving chemical stability.
-
Agriculture and Land Management Freeze-dried soils are used to evaluate soil health parameters, nutrient status, and organic matter content critical for sustainable land use.
-
Research and Laboratory Analysis Provides standardized sample preparation ensuring reproducibility in physicochemical analysis, supporting comparative studies and regulatory compliance.
-
Water Content and Dry Matter Analysis Suitable as a preparatory method especially for samples with high moisture, enabling reliable subsequent gravimetric determinations.
Related Standards
-
ISO 11464: Soil Quality - Pretreatment of Samples for Physico-Chemical Analyses Complements ISO 16720 by detailing methods for preparing soil samples prior to chemical analysis.
-
ISO 11465: Soil Quality - Determination of Dry Matter and Water Content on a Mass Basis - Gravimetric Method Provides standardized gravimetric procedures to measure dry matter and moisture, which can follow freeze-drying pretreatment.
Conclusion
SIST EN ISO 16720:2007 sets out a precise, reproducible method for freeze-drying soil, sludge, and sediment samples preparing them for various analytical determinations. Its method minimizes compound loss and degradation, crucially supporting accurate soil quality evaluations, environmental analyses, and research. Laboratories and environmental agencies adopting this standard benefit from internationally harmonized procedures enhancing data reliability and comparability.
Keywords: soil quality, freeze-drying, sample pretreatment, lyophilization, soil analysis, sludge analysis, sediment pretreatment, dry matter content, water content determination, ISO 16720, CEN standards.
Технические детали
- SKU
- SIST EN ISO 16720:2007
Похожие стандарты
Стандарты, упомянутые в описании
ISO 16720:2005
ДействующийSoil quality — Pretreatment of samples by freeze-drying for subsequent analysis
Overview ISO 16720:2005 is an international standard that specifies the pretreatment of soil samples by freeze-drying to prepare them for subsequent analytical testing. Developed by the International…
SIST ISO 11464:2006
ДействующийSoil quality -- Pretreatment of samples for physico-chemical analysis
Overview ISO 11464:2006 - "Soil quality - Pretreatment of samples for physico-chemical analysis" specifies standardized procedures for preparing soil samples prior to analysis of stable, non‑volatile…
SIST EN ISO 11465:2026
ДействующийSludge and solid environmental matrices - Determination of dry residue or water content and calculation of th…
Overview EN ISO 11465:2025 - Sludge and solid environmental matrices - specifies standardized methods to determine dry residue, water content, and the dry matter fraction (mass basis) for sludge, tre…