SIST EN ISO 16890-3:2024 PDF
Air filters for general ventilation - Part 3: Determination of the gravimetric efficiency and the air flow resistance versus the mass of test dust captured (ISO 16890-3:2024)
Air filters for general ventilation - Part 3: Determination of the gravimetric efficiency and the air flow resistance versus the mass of test dust captured (ISO 16890-3:2024)
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 31
- Дата публикации:
- 17 сентября 2024 г.
- Издание:
- ISO 16890-3:2024
- ICS:
- 91.140.30
This document specifies the test equipment and the test methods used for measuring the gravimetric efficiency and resistance to air flow of air filter for general ventilation. It is intended for use in conjunction with ISO 16890-1, ISO 16890-2 and ISO 16890-4. The test method described in this document is applicable for air flow rates between 0,25 m3/s (900 m3/h, 530 ft3/min) and 1,5 m3/s (5 400 m3/h, 3 178 ft3/min), referring to a test rig with a nominal face area of 610 mm × 610 mm (24 in × 24 in). This document refers to particulate air filter elements for general ventilation having an ePM1 efficiency less than or equal to 99 % and an ePM10 efficiency greater than 20 % when tested as per the procedures defined in the ISO 16890 series. NOTE The lower limit for this test procedure is set at a minimum ePM10 efficiency of 20 % since it is very difficult for a test filter element below this level to meet the statistical validity requirements of this procedure. This document does not apply to filter elements used in portable room-air cleaners.
Abstract
Overview
EN ISO 16890-3:2024 - "Air filters for general ventilation - Part 3: Determination of the gravimetric efficiency and the air flow resistance versus the mass of test dust captured" - specifies the test equipment and procedures for measuring how much dust a general-ventilation air filter captures (gravimetric efficiency) and how its air-flow resistance changes as dust accumulates. The standard is part of the ISO 16890 series and is intended to be used in conjunction with ISO 16890-1, ISO 16890-2 and ISO 16890-4. It applies to tests on a nominal 610 mm × 610 mm (24 in × 24 in) face area with air flow rates between 0.25 m3/s and 1.5 m3/s and covers filter elements with ePM1 ≤ 99% and ePM10 > 20%. It does not apply to portable room-air cleaners.
Key Topics
- Test rig and equipment requirements: specification for a nominal test face area, upstream mixing, dust feeder, liquid-aerosol devices and final filter set-up.
- Air flow range: test applicability from 0.25 m3/s to 1.5 m3/s on the defined rig.
- Gravimetric efficiency measurement: procedures for loading test dust, measuring captured mass and calculating gravimetric efficiency versus captured dust mass.
- Resistance to air flow: methods to measure how pressure drop across the filter increases with dust loading; includes calculation annexes.
- Qualification and calibration: requirements for qualifying the test rig, dust feeder flow rates and final filter efficiency before formal testing.
- Dust-loading sequence and reporting: initial preparation, an updated initial loading step (revised to 60 g in the 2024 edition), dust loading procedure, arrestance, test dust capacity and required reporting elements (summary and detailed results).
- Scope limits: lower limit set because filters with ePM10
Технические детали
- Технический комитет
- I13 - Imaginarni 13
- SKU
- SIST EN ISO 16890-3:2024
Похожие стандарты
Стандарты, упомянутые в описании
ISO 16890-3:2024
ДействующийAir filters for general ventilation — Part 3: Determination of the gravimetric efficiency and the air flow re…
Overview - What ISO 16890-3:2024 covers ISO 16890-3:2024, "Air filters for general ventilation - Part 3", specifies the test equipment and test methods used to measure the gravimetric efficiency and…
SIST EN ISO 16890-1:2017
ДействующийAir filters for general ventilation - Part 1: Technical specifications, requirements and classification syste…
Overview EN ISO 16890-1:2016 establishes a modern, science-based classification and test framework for air filters for general ventilation based on particulate matter efficiency (ePM). Adopted by CEN…
SIST EN ISO 16890-2:2022
ДействующийAir filters for general ventilation - Part 2: Measurement of fractional efficiency and air flow resistance (I…
Overview SIST EN ISO 16890-2:2022 (ISO 16890-2:2022) defines the laboratory test methods for measuring fractional efficiency and air flow resistance of particulate air filter elements used in general…
SIST EN ISO 16890-4:2022
ДействующийAir filters for general ventilation - Part 4: Conditioning method to determine the minimum fractional test ef…
Overview EN ISO 16890-4:2022 - "Air filters for general ventilation - Part 4: Conditioning method to determine the minimum fractional test efficiency" specifies a laboratory conditioning method used…