SIST EN ISO 22476-11:2017 PDF
Geotechnical investigation and testing - Field testing - Part 11: Flat dilatometer test (ISO 22476-11:2017)
Geotechnical investigation and testing - Field testing - Part 11: Flat dilatometer test (ISO 22476-11:2017)
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 24
- Дата публикации:
- 12 сентября 2017 г.
- ICS:
- 93.020
- Технический комитет:
- KON.007 - Geotechnics
ISO 22476-11:2017 establishes guidelines for the equipment requirements, execution of and reporting on flat dilatometer tests. NOTE This document fulfils the requirements for flat dilatometer tests as part of the geotechnical investigation and testing according to EN 1997‑1 and EN 1997‑2. The basic flat dilatometer test consists of inserting vertically into the soil a blade-shaped steel probe with a thin expandable circular steel membrane mounted flush on one face and determining two pressures at selected depth intervals: the contact pressure exerted by the soil against the membrane when the membrane is flush with the blade and, subsequently, the pressure exerted when the central displacement of the membrane reaches 1,10 mm. Results of flat dilatometer tests are used mostly to obtain information on soil stratigraphy, in situ state of stress, deformation properties and shear strength. It is also used to detect slip surfaces in clays. The flat dilatometer test is most applicable to clays, silts and sands, where particles are small compared to the size of the membrane.
Abstract
Overview
EN ISO 22476-11:2017 - Geotechnical investigation and testing - Part 11: Flat dilatometer test (DMT) - provides standardized guidelines for equipment, execution and reporting of the flat dilatometer test. This ISO-adopted CEN standard describes the DMT procedure used in in situ geotechnical investigation and fulfils requirements of EN 1997‑1 and EN 1997‑2 for site investigation.
The flat dilatometer test uses a blade-shaped steel probe with a thin circular steel membrane mounted flush on one face. Two key pressure readings are obtained at selected depth intervals: the contact pressure when the membrane is flush and the pressure when the membrane centre reaches 1.10 mm deflection (with an initial signal at 0.05 mm). DMT results inform soil stratigraphy, in situ stress state, deformation properties and shear strength, and can detect slip surfaces in clays. It is most applicable to clays, silts and fine sands.
Key Topics and Requirements
- Equipment: Requirements for the dilatometer blade, membrane, pneumatic-electric cable, control and calibration unit, insertion apparatus and pressure source.
- Switch mechanism & signals: Internal blade switch that signals membrane deflections at 0.05 mm (A-pressure) and 1.10 mm (B-pressure).
- Measured pressures: Definitions and use of A-pressure, B-pressure and C-pressure (pressure when membrane returns towards A-position).
- Membrane calibration: Procedures to calibrate A and B membrane responses (air calibration pressures ΔA and ΔB) and gauge zero checks.
- Test procedure: Guidance on maintenance, insertion, sounding increments (commonly 100–300 mm), basic test sequence, dissipation tests (DMTA and DMTA‑s), and safety.
- Reporting: Required test documentation, site and equipment details, raw and corrected pressure data, interpretation notes and presentation of results.
- Informative annexes: Example interpretation formulae and references to other parts of the ISO 22476 series.
Applications and Users
Who uses EN ISO 22476-11:2017:
- Geotechnical and geotechnical site investigation engineers
- Engineering geologists and consultants
- Construction contractors and piling/subsurface works teams
- Testing laboratories and QA/QC personnel
- Regulators and authors of ground investigation specifications
Practical applications:
- Characterising soil stratigraphy and layering
- Estimating in situ stress, stiffness and deformation properties
- Assessing shear strength and detection of potential slip surfaces in clayey ground
- Complementing CPT, SPT and laboratory testing in foundation and earthworks design
Related Standards
- EN 1997‑1 / EN 1997‑2 (geotechnical design & investigations) - DMT fulfils their field-testing requirements
- Other parts of ISO 22476 (field testing series) for complementary in situ tests
Keywords: EN ISO 22476-11:2017, flat dilatometer test, DMT, geotechnical investigation, in situ testing, A-pressure, B-pressure, C-pressure, membrane calibration, dilatometer blade, soil stratigraphy.
Технические детали
- SKU
- SIST EN ISO 22476-11:2017
Похожие стандарты
Упомянутые в описании и другие стандарты SIST
ISO 22476-11:2017
ДействующийGeotechnical investigation and testing — Field testing — Part 11: Flat dilatometer test
Overview - ISO 22476-11:2017 (Flat dilatometer test, DMT) ISO 22476-11:2017 specifies requirements for performing and reporting the flat dilatometer test (DMT) as part of geotechnical investigation a…
BS EN ISO 22476-1:2023
ДействующийGeotechnical investigation and testing. Field testing. Electrical cone and piezocone penetration test.
SIST EN ISO 6338:2026
ДействующийMethod to calculate GHG emissions at LNG plant (ISO 6338:2023)
Overview SIST EN ISO 6338:2026 / ISO 6338:2023 establishes a standardized method for calculating greenhouse gas (GHG) emissions at liquefied natural gas (LNG) plants, both onshore and offshore. Devel…
SIST-TP CEN ISO/ASTM TR 52958:2026
Additive manufacturing of metals - Powder bed fusion (PBF) - In-situ coaxial photodiode monitoring for lack o…
Overview SIST-TP CEN ISO/ASTM TR 52958:2026 specifies a workflow for the detection of lack of fusion flaws during the additive manufacturing of metals using powder bed fusion-laser based (PBF-LB) pro…
SIST EN ISO 41002:2026
ДействующийFacility management - Development of the facility management organization (ISO 41002:2026)
Overview SIST EN ISO 41002:2026 - Facility management - Development of the facility management organization offers strategic guidance for building and developing robust facility management (FM) organ…
SIST EN ISO 844:2026
ДействующийRigid cellular plastics - Determination of compressive properties (ISO 844:2026)
Overview SIST EN ISO 844:2026 - Rigid Cellular Plastics: Determination of Compressive Properties (ISO 844:2026) provides standardized methods for measuring the compressive properties of rigid cellula…
SIST-TS CEN ISO/TS 17664-3:2026
ДействующийProcessing of health care products - Information to be provided by the medical device manufacturer for the pr…
Overview SIST-TS CEN ISO/TS 17664-3:2026 sets out comprehensive guidance for grouping reusable medical devices based on their cleaning requirements. This technical specification, prepared collaborati…
SIST EN ISO 8980-4:2026
ДействующийOphthalmic optics - Uncut finished spectacle lenses - Part 4: Specifications and test methods for the propert…
Overview SIST EN ISO 8980-4:2026 specifies requirements and test methods for the properties of anti-reflective coatings and hydrophobic coatings applied to uncut finished spectacle lenses. Developed…