SIST EN ISO 26782:2009 PDF
Anaesthetic and respiratory equipment - Spirometers intended for the measurement of time forced expired volumes in humans (ISO 26782:2009)
Anaesthetic and respiratory equipment - Spirometers intended for the measurement of time forced expired volumes in humans (ISO 26782:2009)
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 37
- Дата публикации:
- 13 октября 2009 г.
- ICS:
- 11.040.10
- Технический комитет:
- VAZ - Healthcare
ISO 26782:2009 specifies requirements for spirometers intended for the assessment of pulmonary function in humans weighing more than 10 kg. ISO 26782:2009 applies to spirometers that measure timed forced expired volumes, either as part of an integrated lung function device or as a stand-alone device, irrespective of the measuring method employed.
Abstract
Overview
EN ISO 26782:2009 - Anaesthetic and respiratory equipment - Spirometers intended for the measurement of time forced expired volumes in humans - is a CEN-adopted ISO standard that specifies requirements for spirometers used to assess pulmonary function in humans weighing more than 10 kg. It applies to stand‑alone spirometers and spirometric modules integrated into larger lung function systems, regardless of measurement technology. The standard defines performance, safety, marking and documentation expectations and includes normative test methods and informative guidance.
Key Topics
- Scope and applicability: Devices for measuring timed forced expired volumes in humans (>10 kg), either integrated or stand‑alone.
- Performance requirements: Accuracy, linearity, repeatability and defined measurement ranges to ensure reliable timed volume measurements.
- Time criteria: Defined criteria for start and end of forced exhalation and for recording time and volume traces.
- Construction and safety: Electrical and mechanical safety requirements, impact/drop considerations for hand‑held components, and calibration provisions.
- User information and marking: Legibility, durability of markings, labelling of devices and packaging, and comprehensive instructions for use and technical descriptions.
- Hygiene and biocompatibility: Requirements for cleaning, disinfection, sterilization and biocompatibility of reusable and single‑use parts.
- Testing and verification: Normative test methods (Annex B) and defined test profiles (Annex C) for assessing accuracy, linearity and expiratory impedance.
- Regulatory alignment: Informative Annex ZA maps the standard to Essential Requirements of EU Directive 93/42/EEC (medical devices); references to electrical safety standards such as IEC 60601‑1 are noted.
- Supporting information: Annexes cover rationale, environmental aspects and conformity references.
Applications
EN ISO 26782:2009 is used to:
- Provide manufacturers with performance and safety criteria for design, verification and labeling of spirometers.
- Support test laboratories and quality teams in validating device accuracy, repeatability and calibration procedures.
- Help regulatory and compliance professionals demonstrate conformity with medical device directives and national standards.
- Guide hospital biomedical engineering, clinical respiratory departments and procurement teams in specifying and evaluating spirometers for clinical use, screening, pre‑operative assessment and research.
Who should use this standard
- Medical device manufacturers and designers of spirometers and lung function systems
- Test laboratories and conformity assessment bodies
- Regulatory affairs and quality assurance teams
- Clinical engineers, respiratory therapists and hospital procurement officers
- Standards committees and technical reviewers
Related standards
- IEC 60601‑1 (electrical safety of medical electrical equipment)
- ATS/ERS recommendations for spirometry (standardization guidance referenced in the ISO introduction)
Keywords: EN ISO 26782:2009, spirometer standard, spirometry, pulmonary function testing, timed forced expired volumes, medical device standard, CEN, IEC 60601-1.
Технические детали
- SKU
- SIST EN ISO 26782:2009
Похожие стандарты
Стандарты, упомянутые в описании
ISO 26782:2009
ДействующийAnaesthetic and respiratory equipment — Spirometers intended for the measurement of time forced expired volum…
Overview ISO 26782:2009 - "Anaesthetic and respiratory equipment - Spirometers intended for the measurement of time forced expired volumes in humans" defines requirements for spirometers used to asse…
IEC 60601-1:2005
ДействующийMedical electrical equipment - Part 1: General requirements for basic safety and essential performance
Overview IEC 60601-1:2005 (Consolidated Edition 3.1, with Amendment 1) is the international safety standard for medical electrical equipment, defining the general requirements for basic safety and es…
PD IEC/TR 62296:2009
ДействующийConsiderations of unaddressed safety aspects in the second edition of IEC 60601-1 and proposals for new requi…
What is PD IEC/TR 62296 - Considerations of unaddressed safety aspects in the second edition of IEC 60601-1 about? PD IEC/TR 62296 is a technical report that discusses the considerations of unaddress…