SIST EN ISO 2871-1:2010 PDF
Surface active agents - Detergents - Determination of cationic-active matter content - Part 1: High-molecular-mass cationic-active matter (ISO 2871-1:2010)
Surface active agents - Detergents - Determination of cationic-active matter content - Part 1: High-molecular-mass cationic-active matter (ISO 2871-1:2010)
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 10
- Дата публикации:
- 19 августа 2010 г.
- ICS:
- 71.100.40
- Технический комитет:
- KDS - Cosmetics, chemical disinfectants and surface active agents
ISO 2871-1:2010 specifies a method for the determination of high-molecular-mass cationic-active materials such as quaternary ammonium compounds in which two of the alkyl groups each contain 10 or more carbon atoms, e.g. distearyl-dimethyl-ammonium chlorides, or salts of imidazoline or 3-methylimidazoline in which long-chain acylaminoethyl and alkyl groups are substituted in the 1- and 2-positions, respectively. The method is applicable to solids or to aqueous solutions of the active material. The method is not applicable if anionic surface active agents are present.
Abstract
Overview
EN ISO 2871-1:2010 (ISO 2871-1:2010) specifies a validated laboratory method for the determination of high‑molecular‑mass cationic‑active matter in detergents and surface‑active agent formulations. It covers quaternary ammonium compounds where two alkyl groups have ≥10 carbon atoms (e.g., distearyl‑dimethyl‑ammonium chlorides) and certain imidazoline‑based salts. The procedure applies to solids and aqueous solutions when the relative molecular mass of the cationic material is known or previously determined. The method is not applicable if anionic surfactants are present.
Key topics and technical requirements
- Analytical principle: direct two‑phase titration - titration of a standard sodium lauryl sulfate solution with the test sample (referencing ISO 2271).
- Reagents: chloroform, propan‑2‑ol (isopropanol), a standard sodium lauryl sulfate solution and a mixed indicator (as specified in ISO 2271).
- Apparatus: ordinary laboratory glassware plus class A burette and one‑mark 1 000 ml volumetric flask (ISO 385, ISO 1042).
- Sample preparation: dissolve weighed test portion in propan‑2‑ol, dilute to 1 000 ml with water to prepare the titrant solution.
- Titration procedure: titrate 10 ml of the sodium lauryl sulfate standard against the prepared test solution; observe colour changes in the chloroform phase to identify end point.
- Expression of results: cationic content reported as percentage by mass, calculated from titration volume, SLS concentration, sample mass and the relative molecular mass of the cationic species.
- Performance characteristics: repeatability limit ≈ 1.5% of the mean; reproducibility limit ≈ 3% of the mean.
- Limitations and interferences: method tolerates certain non‑ionic agents and common inorganic detergent ingredients; it fails in presence of anionic surfactants. Some hydrotropes or bleaching agents may require evaluation or destruction prior to analysis.
Applications and who uses this standard
- Quality control and formulation testing in detergent, textile, household‑care and personal‑care manufacturing.
- Analytical and regulatory laboratories verifying cationic surfactant content for labelling, compliance and batch release.
- R&D groups characterizing high‑molecular‑mass quaternary ammonium compounds and imidazoline derivatives.
- Standards committees and testing service providers adopting a harmonized titration method for consistent reporting.
Keywords: EN ISO 2871-1:2010, ISO 2871-1:2010, determination of cationic-active matter, high-molecular-mass cationic-active matter, detergents, surface active agents, direct two-phase titration, sodium lauryl sulfate.
Related standards
- ISO 2271 - Determination of anionic‑active matter (direct two‑phase titration)
- ISO 607 - Sample division for surface active agents
- ISO 385, ISO 1042 - Laboratory glassware specifications
- ISO 2871‑2 - Cationic‑active matter of low molecular mass (200–500)
Технические детали
- SKU
- SIST EN ISO 2871-1:2010
Похожие стандарты
Стандарты, упомянутые в описании
ISO 2871-1:2010
ДействующийSurface active agents — Detergents — Determination of cationic-active matter content — Part 1: High-molecular…
Overview - ISO 2871-1:2010 (cationic-active matter, high-molecular-mass) ISO 2871-1:2010 specifies a laboratory method for determining the content of high-molecular-mass cationic-active matter in det…
ISO 22717:2015/Amd 1:2022
ДействующийCosmetics — Microbiology — Detection of Pseudomonas aeruginosa — Amendment 1
Overview ISO 22717:2015/Amd 1:2022 is an important amendment to the international standard focusing on microbiological detection of Pseudomonas aeruginosa in cosmetics. Developed by ISO Technical Com…
BS EN ISO 385:2005
ДействующийLaboratory glassware. Burettes.
BS EN ISO 10427-1:2024
ДействующийOil and gas industries including lower carbon energy. Equipment for well cementing. Casing bow-spring central…
SIST EN ISO 6076:2023
ДействующийAdhesives - Installation of floor coverings, wood flooring, levelling compounds and tiles - Specification of…
Overview - EN ISO 6076:2023 (trowel notch sizes) EN ISO 6076:2023 (ISO 6076:2023, corrected version 2023-09) specifies the dimensional characteristics and coding of notched trowels and notched strips…
SIST EN ISO 2871-2:2010
ДействующийSurface active agents - Detergents - Determination of cationic-active matter content - Part 2: Cationic-activ…
Overview SIST EN ISO 2871-2:2010 is a European and international standard specifying the method for determining the cationic-active matter content in detergents and surface active agents with low mol…