SIST EN ISO 3838:2004 PDF
Crude petroleum and liquid or solid petroleum products - Determination of density or relative density - Capillary-stoppered pyknometer and graduated bicapillary pyknometer methods (ISO 3838:2004)
Crude petroleum and liquid or solid petroleum products - Determination of density or relative density - Capillary-stoppered pyknometer and graduated bicapillary pyknometer methods (ISO 3838:2004)
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 20
- Дата публикации:
- 1 сентября 2004 г.
- ICS:
- 75.040
- Технический комитет:
- NAD - Petroleum products, lubricants and related products
ISO 3838:2004 specifies methods for the determination of the density or relative density of crude petroleum and of petroleum products handled as liquids. The capillary-stoppered pyknometer method is also for use with solids and this method may also be used for coal tar products, including road tars, creosote and tar pitches, or for mixtures of these with petroleum products. This method is not suitable for the determination of the density or relative density of highly volatile liquids having Reid vapour pressures greater than 50 kPa according to ISO 3007 or having an initial boiling point below 40 degrees Celsius. The graduated bicapillary pyknometer method is recommended for the accurate determination of the density or relative density of all except the more viscous products, and is particularly useful when only small amounts of samples are available. The method is restricted to liquids having Reid vapour pressures of 130 kPa or less according to ISO 3007 and having kinematic viscosities less than 50 mm2/s (50 centistokes (cSt)) at the test temperature. Special precautions are specified for the determination of the density or relative density of highly volatile liquids.
Abstract
Overview
EN ISO 3838:2004 (ISO 3838:2004) specifies laboratory methods for the determination of density or relative density of crude petroleum and petroleum products using two pyknometer techniques: the capillary‑stoppered pyknometer and the graduated bicapillary (Lipkin) pyknometer. The document covers scope, apparatus, calibration, test procedures, corrections (thermal expansion and buoyancy), and reporting. It includes special precautions for highly volatile liquids and provisions to handle solids and viscous materials where applicable.
Key topics and technical requirements
- Scope and applicability
- For crude petroleum and petroleum products handled as liquids.
- Capillary‑stoppered pyknometer: also suitable for solids and coal‑tar products (road tars, creosote, tar pitches) and mixtures with petroleum. Not suitable for highly volatile liquids with Reid vapour pressure > 50 kPa or initial boiling point
Технические детали
- SKU
- SIST EN ISO 3838:2004
Похожие стандарты
Упомянутые в описании и другие стандарты SIST