SIST EN ISO 5814:2013 PDF
Water quality - Determination of dissolved oxygen - Electrochemical probe method (ISO 5814:2012)
Water quality - Determination of dissolved oxygen - Electrochemical probe method (ISO 5814:2012)
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 21
- Дата публикации:
- 28 декабря 2012 г.
- ICS:
- 13.060.50
- Технический комитет:
- KAV - Water quality
ISO 5814:2012 specifies an electrochemical method for the determination of dissolved oxygen in water by means of an electrochemical cell which is isolated from the sample by a gas permeable membrane. Measurement can be made either as a concentration of oxygen in milligrams per litre, percentage saturation (% dissolved oxygen) or both. The method measures oxygen in water corresponding to 1 % to 100 % saturation. However, most instruments permit measurement of values higher than 100 %, i.e. supersaturation. The method measures oxygen in water with a saturation higher than 100 %, when special arrangements to prevent the outgassing of oxygen during the handling and measurement of the sample are made. The method is suitable for measurements made in the field and for continuous monitoring of dissolved oxygen, as well as measurements made in the laboratory. It is the preferred method for highly coloured and turbid waters, and also for analysis of waters not suitable for the Winkler titration method because of iron- and iodine-fixing substances, which can interfere in the iodometric method specified in ISO 5813. The method is suitable for drinking waters, natural waters, waste waters, and saline waters. If used for saline waters, such as sea or estuarine waters, a correction for salinity is essential.
Abstract
Overview
EN ISO 5814:2012 - "Water quality - Determination of dissolved oxygen - Electrochemical probe method" specifies an electrochemical probe technique for measuring dissolved oxygen (DO) in water. The method uses a probe with an electrochemical cell isolated from the sample by a gas‑permeable membrane and reports results in mg/L and/or % saturation. It is applicable for in‑field measurements, continuous monitoring and laboratory analysis of drinking, natural, saline and waste waters.
Key topics and technical requirements
- Measurement principle: Probe (galvanic or polarographic) reduces oxygen at a noble‑metal electrode; resulting current is proportional to oxygen partial pressure through the membrane.
- Sensor types: Examples given include galvanic (e.g., lead/silver) and polarographic (e.g., silver/gold) probes; built‑in temperature compensation is required because temperature affects membrane permeability and electrode reactions.
- Measurement range: Designed for 1% to 100% saturation; most instruments can read above 100% (supersaturation). Special handling is required to measure supersaturated samples without outgassing.
- Calibration: A calibration procedure using water‑saturated air is specified (edition change vs previous methods). Routine checks: daily calibration at air saturation and after significant ambient changes (temperature/pressure).
- Sampling and handling: Prefer in‑situ measurement. If sampling is needed, use gas‑tight, laminar transfer (dip sampling, water‑displacing submersible pumps, flow‑through cells). Avoid air bubbles and turbulence to prevent oxygen exchange.
- Interferences and maintenance: Gases (chlorine, H2S, bromine, iodine, amines, ammonia) and substances (solvents, oils, sulfides, biofilms) can diffuse through or foul the membrane and affect readings. Ensure membrane integrity, adequate polarization time and follow manufacturer maintenance.
- Compensation requirements: Correct for temperature, atmospheric pressure, and - for saline waters (sea/estuarine) - salinity.
Applications and users
EN ISO 5814:2012 is widely used for:
- Field and continuous monitoring of rivers, lakes, estuaries and coastal waters
- Wastewater treatment process monitoring and control
- Drinking water and distribution system checks
- Research on oxygen dynamics, eutrophication and algal blooms (including supersaturation events) Primary users:
- Environmental and water quality laboratories
- Water and wastewater treatment operators
- Regulatory agencies and environmental consultants
- Researchers conducting aquatic monitoring and process control
Related standards
- ISO 5813 - iodometric (Winkler) method for dissolved oxygen (reference for samples where electrochemical probes are unsuitable)
- ISO 3696 - water for analytical laboratory use (reagents/grade)
- EN ISO 5814:2012 supersedes EN 25814:1992
Keywords: EN ISO 5814:2012, dissolved oxygen, electrochemical probe, water quality, DO measurement, field monitoring, calibration, salinity correction.
Технические детали
- SKU
- SIST EN ISO 5814:2013
Похожие стандарты
Стандарты, упомянутые в описании
ISO 5814:2012
ДействующийWater quality — Determination of dissolved oxygen — Electrochemical probe method
Overview ISO 5814:2012 - "Water quality - Determination of dissolved oxygen - Electrochemical probe method" - specifies an electrochemical probe procedure for measuring dissolved oxygen (DO) in water…
SIST EN 25813:1996
ДействующийWater quality - Determination of dissolved oxygen - Iodometric method (ISO 5813:1983)
Overview SIST EN 25813:1996, titled "Water quality - Determination of dissolved oxygen - Iodometric method (ISO 5813:1983)," is a European Standard developed by CEN. It specifies a modified Winkler t…
SIST EN ISO 3696:1998
ДействующийWater for analytical laboratory use - Specification and test methods (ISO 3696:1987)
Overview EN ISO 3696:1995 (ISO 3696:1987) – "Water for analytical laboratory use – Specification and test methods" is a CEN-adopted international standard that defines quality grades, specification l…