SIST EN ISO 6926:2016 PDF
Acoustics - Requirements for the performance and calibration of reference sound sources used for the determination of sound power levels (ISO 6926:2016)
Acoustics - Requirements for the performance and calibration of reference sound sources used for the determination of sound power levels (ISO 6926:2016)
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 29
- Дата публикации:
- 14 марта 2016 г.
- ICS:
- 17.140.01
- Технический комитет:
- AKU - Acoustics
ISO 6926:2016 specifies the acoustical performance requirements for reference sound sources: - temporal steadiness (stability) of the sound power output; - spectral characteristics; - directivity. Temporal steadiness is defined in terms of the standard deviation of repeatability (see 5.2). The spectral characteristics can be verified in either a hemi-anechoic room or a reverberation test room from measurements of the frequency band sound power levels in accordance with this International Standard (see 5.4). The performance requirements on directivity index can only be verified in a hemi-anechoic room (see 5.5.) ISO 6926:2016 also specifies procedures for providing level calibration data and uncertainty on a sound source intended for use as a reference sound source in terms of its sound power level under reference meteorological conditions as defined in Clause 4 in octave and in one-third-octave bands, and with frequency weighting A. ISO 6926:2016 is titled as a calibration standard even though the method is conducted in a testing laboratory and the level calibration results are not directly traceable to national standards of measure in a strict metrological sense. Testing laboratories performing this method are not expected to meet all requirements normally associated with a calibration laboratory. NOTE ISO/IEC 17025[15] specifies different requirements for the competence of testing laboratories and calibration laboratories respectively. Laboratories testing reference sound sources in accordance with this International Standard would typically comply with the requirements for testing laboratories but not necessarily with those for calibration laboratories. ISO 6926:2016 specifies methods to calibrate reference sound sources not only in a free field over a reflecting plane but also in reverberation test rooms at different distances from the boundary surfaces. For the position of the reference sound source on one reflecting plane, the two different test environments mentioned above are considered equivalent for frequency bands above or equal to 200 Hz. At 160 Hz and below, some systematic differences can occur (see 11.2). For frequencies below 100 Hz, an alternative calibration method using sound intensity is given. The sound source can either be placed directly on the floor or mounted on a stand to be used at a certain elevation above the floor. According to this International Standard, stand-mounted sources are calibrated in reverberation test rooms. Floor-mounted sources are either calibrated in hemi-anechoic or in reverberation test rooms. For floor-mounted sources in hemi-anechoic rooms, this International Standard is valid only for sources whose maximum vertical dimension is less than 0,5 m and whose maximum horizontal dimension is less than 0,8 m. According to this International Standard, only floor-mounted reference sound sources can be used when carrying out measurements on a measurement surface. For reference sound sources to be used or calibrated under reverberant conditions, no such restrictions on maximum dimensions apply.
Abstract
Overview - EN ISO 6926:2016 (Acoustics, Reference Sound Sources)
EN ISO 6926:2016 specifies performance and calibration requirements for reference sound sources used to determine sound power levels. Published by CEN and identical to ISO 6926:2016, it defines how to verify the stability, spectral output and directivity of reference sources and how to provide calibrated level data with associated uncertainty (octave and 1/3-octave bands, A‑weighting) under reference meteorological conditions.
Key topics and technical requirements
-
Temporal steadiness (stability)
- Stability is expressed as the standard deviation of repeatability (see clause 5.2). Laboratories must measure and report temporal steadiness over repeated runs.
-
Spectral characteristics
- Verification of frequency‑band sound power levels can be performed in a hemi‑anechoic room or a reverberation test room (see clause 5.4).
-
Directivity
- Directivity index performance requirements can only be verified in a hemi‑anechoic room (see clause 5.5).
-
Calibration environments and frequency considerations
- For a source on one reflecting plane, hemi‑anechoic and reverberation room results are considered equivalent for frequencies ≥ 200 Hz. Systematic differences may occur at 160 Hz and below; alternative sound‑intensity calibration is specified for frequencies
Технические детали
- SKU
- SIST EN ISO 6926:2016
Похожие стандарты
Упомянутые в описании и другие стандарты SIST
ISO 6926:2016
ДействующийAcoustics — Requirements for the performance and calibration of reference sound sources used for the determin…
Overview ISO 6926:2016 - Acoustics - Requirements for the performance and calibration of reference sound sources used for the determination of sound power levels - defines performance criteria and ca…
SIST EN ISO 6338:2026
ДействующийMethod to calculate GHG emissions at LNG plant (ISO 6338:2023)
Overview SIST EN ISO 6338:2026 / ISO 6338:2023 establishes a standardized method for calculating greenhouse gas (GHG) emissions at liquefied natural gas (LNG) plants, both onshore and offshore. Devel…
SIST-TP CEN ISO/ASTM TR 52958:2026
Additive manufacturing of metals - Powder bed fusion (PBF) - In-situ coaxial photodiode monitoring for lack o…
Overview SIST-TP CEN ISO/ASTM TR 52958:2026 specifies a workflow for the detection of lack of fusion flaws during the additive manufacturing of metals using powder bed fusion-laser based (PBF-LB) pro…
SIST EN ISO 41002:2026
ДействующийFacility management - Development of the facility management organization (ISO 41002:2026)
Overview SIST EN ISO 41002:2026 - Facility management - Development of the facility management organization offers strategic guidance for building and developing robust facility management (FM) organ…
SIST EN ISO 844:2026
ДействующийRigid cellular plastics - Determination of compressive properties (ISO 844:2026)
Overview SIST EN ISO 844:2026 - Rigid Cellular Plastics: Determination of Compressive Properties (ISO 844:2026) provides standardized methods for measuring the compressive properties of rigid cellula…
SIST-TS CEN ISO/TS 17664-3:2026
ДействующийProcessing of health care products - Information to be provided by the medical device manufacturer for the pr…
Overview SIST-TS CEN ISO/TS 17664-3:2026 sets out comprehensive guidance for grouping reusable medical devices based on their cleaning requirements. This technical specification, prepared collaborati…
SIST EN ISO 8980-4:2026
ДействующийOphthalmic optics - Uncut finished spectacle lenses - Part 4: Specifications and test methods for the propert…
Overview SIST EN ISO 8980-4:2026 specifies requirements and test methods for the properties of anti-reflective coatings and hydrophobic coatings applied to uncut finished spectacle lenses. Developed…
SIST EN ISO 5361:2023/A1:2026
ДействующийAnaesthetic and respiratory equipment - Tracheal tubes and connectors - Amendment 1: Reinstatement of third e…
Overview SIST EN ISO 5361:2023/A1:2026 is an amendment to the internationally recognized ISO 5361:2023 standard, which specifies requirements for anaesthetic and respiratory equipment, with a focus o…