SIST EN ISO 8253-2:2010 PDF
Acoustics - Audiometric test methods - Part 2: Sound field audiometry with pure-tone and narrow-band test signals (ISO 8253-2:2009)
Acoustics - Audiometric test methods - Part 2: Sound field audiometry with pure-tone and narrow-band test signals (ISO 8253-2:2009)
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 24
- Дата публикации:
- 15 марта 2010 г.
- ICS:
- 13.140
- Технический комитет:
- AKU - Acoustics
ISO 8253-2:2009 specifies relevant test signal characteristics, requirements for free, diffuse, and quasi‑free sound fields, and procedures for sound field audiometry using pure tones, frequency-modulated tones or other narrow-band test signals presented by means of one or more loudspeakers. The primary purpose is the determination of hearing threshold levels in the frequency range 125 Hz to 8 000 Hz, but this range can be extended to 20 Hz to 16 000 Hz. ISO 8253-2:2009 does not include specifications for the use of hand-held loudspeakers. Speech as a test signal is not covered. The purpose of ISO 8253-2:2009 is to ensure that tests of hearing, using sound field audiometry, give as high a degree of accuracy and reproducibility as possible. Examples of graphical representations of the results are given.
Abstract
Overview
EN ISO 8253-2:2009 - "Acoustics - Audiometric test methods - Part 2: Sound field audiometry with pure‑tone and narrow‑band test signals" (CEN adoption of ISO 8253‑2:2009) defines procedures, signal characteristics and room conditions for performing reliable sound field audiometry. Its primary purpose is to ensure accurate, reproducible determination of hearing threshold levels in the frequency range 125 Hz to 8 000 Hz (extendable to 20 Hz to 16 000 Hz). The standard covers tests using pure tones, frequency‑modulated (FM) tones and narrow‑band noise presented via one or more loudspeakers. It explicitly excludes hand‑held loudspeakers and speech test signals.
Key topics and technical requirements
- Test signal characteristics: Definitions and requirements for pure tones, FM tones and narrow‑band signals, including gating, harmonic distortion limits and level control.
- Sound field definitions: Requirements for free, diffuse and quasi‑free sound fields and how room acoustics and speaker arrangement affect measurements.
- Reference points and axes: Positioning of the listener (reference point) relative to loudspeakers and reference axis for reproducible presentation.
- Ambient noise limits: Maximum permissible background noise in the test room to protect threshold accuracy.
- Calibration and measurement scales: Means and scales for equipment calibration (SPL and hearing level references), and reference thresholds under free‑field/diffuse conditions.
- Test procedures: Guidance for monaural and binaural threshold determination, testing with hearing aids, and screening audiometry procedures.
- Reporting and graphical presentation: Recommended formats for reporting results and example graphical displays (Annex A).
- Maintenance and calibration regime: Multi‑stage approach to equipment upkeep (routine listening and checks, periodic electroacoustic tests, and basic calibration tests - Stage A, B, C).
Applications and who uses it
EN ISO 8253‑2:2009 is used by:
- Audiologists and clinicians performing pediatric or behavioural sound field audiometry.
- Hearing aid dispensers and researchers measuring functional gain with worn devices.
- Clinical engineers and medical physicists responsible for audiometric room setup, calibration and quality assurance.
- Manufacturers of audiometric equipment and loudspeakers to ensure product compatibility with standardized test conditions.
- Occupational health professionals conducting hearing screening where sound field methods are appropriate.
Practical benefits include improved measurement reproducibility, comparable clinical records across facilities, and validated procedures for evaluating hearing aids and sound‑presentation setups.
Related standards
- ISO 8253‑1 (Basic pure‑tone air and bone conduction audiometry)
- ISO 8253‑3 (Speech audiometry)
- ISO 226, ISO 266, ISO 389‑7 (reference acoustics)
- IEC 60645‑1, IEC 61672‑1, IEC 60581‑7 (audiometric and electroacoustic equipment)
Keywords: EN ISO 8253‑2:2009, sound field audiometry, pure‑tone, narrow‑band, hearing threshold, audiometric test methods, free field, diffuse field, calibration.
Технические детали
- SKU
- SIST EN ISO 8253-2:2010
Похожие стандарты
Стандарты, упомянутые в описании
ISO 8253-2:2009
ДействующийAcoustics — Audiometric test methods — Part 2: Sound field audiometry with pure-tone and narrow-band test sig…
Overview ISO 8253-2:2009 - Acoustics: Audiometric test methods - Part 2 defines requirements and procedures for sound field audiometry using pure tones, frequency‑modulated (FM) tones, and narrow‑ban…
SIST EN ISO 8253-1:2011
ДействующийAcoustics - Audiometric test methods - Part 1: Pure-tone air and bone conduction audiometry (ISO 8253-1:2010)
Overview EN ISO 8253-1:2010 - "Acoustics - Audiometric test methods - Part 1: Pure‑tone air and bone conduction audiometry" (CEN adoption of ISO 8253-1:2010) defines standardized procedures and requi…
SIST EN ISO 8253-3:2022
ДействующийAcoustics - Audiometric test methods - Part 3: Speech audiometry (ISO 8253-3:2022)
Overview EN ISO 8253-3:2022 - Acoustics: Audiometric test methods - Part 3: Speech audiometry (ISO 8253-3:2022) establishes standardized procedures for speech recognition tests used in audiological a…
BS ISO 22640:2023
ДействующийRubber. Framework for physical and chemical characterization of tyre and road wear particles (TRWP).
BS ISO 26683-3:2019
ДействующийIntelligent transport systems. Freight land conveyance content identification and communication. Monitoring c…
SIST EN ISO 389-7:2020
ДействующийAcoustics - Reference zero for the calibration of audiometric equipment - Part 7: Reference threshold of hear…
Overview - EN ISO 389-7:2019 (Acoustics, Reference Threshold of Hearing) EN ISO 389-7:2019 specifies the reference threshold of hearing used to calibrate audiometric equipment when tests are performe…
IEC 60645-1:2017
ДействующийElectroacoustics - Audiometric equipment - Part 1: Equipment for pure-tone and speech audiometry
Overview IEC 60645-1:2017 - "Electroacoustics - Audiometric equipment - Part 1: Equipment for pure‑tone and speech audiometry" is an international standard that specifies general technical and perfor…
IEC 61672-1:2013
ДействующийElectroacoustics - Sound level meters - Part 1: Specifications
Overview IEC 61672-1:2013 is an international standard published by the International Electrotechnical Commission (IEC) that specifies the performance requirements for sound level meters used in elec…