SIST ISO 12238:2023 PDF
Pneumatic fluid power - Directional control valves - Measurement of shifting time
Pneumatic fluid power - Directional control valves - Measurement of shifting time
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 22
- Дата публикации:
- 14 марта 2023 г.
- Издание:
- ISO IS 12238 edition 2 version 1
- ICS:
- 23.100.50
This document specifies test procedures for measuring the shifting times of electrically or pneumatically operated directional control valves. It is applicable to monostable and bistable pneumatic directional control valves, with 2 or 3 position functions.
Abstract
Overview
SIST ISO 12238:2023 - "Pneumatic fluid power - Directional control valves - Measurement of shifting time" defines standardized test procedures for measuring the shifting time of electrically or pneumatically operated directional control valves. The standard applies to monostable and bistable pneumatic directional control valves with 2‑position or 3‑position functions and clarifies how to record and report shifting on‑time and off‑time into exhausting, filling and non‑exhausting positions.
Key technical topics and requirements
- Definitions:
- Shifting time (exhaust) - time for a 10% change in outlet pressure when shifting to an exhausting position.
- Shifting time (fill) - time for a 10% change in outlet pressure when shifting to a filling position.
- Shifting time (non‑exhausting) - measurement method when the working port is closed.
- Test equipment and setup:
- Use straight pressure measuring tubes in accordance with ISO 6358‑1; transition connectors optional.
- Install pressure transducers at inlet and each tested outlet port; plug untested ports.
- For non‑exhausting positions use a throttle valve and flow sensor to generate measurable pressure change.
- For pneumatically operated control, ensure the control valve sonic conductance exceeds that of the pilot port.
- Control signal and electrical requirements:
- AC solenoids: trigger at zero‑voltage crossover; maintain voltage within ±2%.
- DC solenoids: steady voltage within ±2%; negative‑peak limitations must not change shifting time by more than 0.1 ms.
- Bistable valves: include a pause between actuations to exhaust pilot volumes before measuring reverse shifting time.
- Data acquisition:
- System frequency response: –3 dB at ≥ 2 000 Hz (≥ 5 000 Hz for shifting times
Технические детали
- Технический комитет
- IHPV - Hydraulics and pneumatics
- SKU
- SIST ISO 12238:2023
Похожие стандарты
Упомянутые в описании и другие стандарты SIST
ISO 12238:2023
ДействующийPneumatic fluid power — Directional control valves — Measurement of shifting time
Overview ISO 12238:2023 - "Pneumatic fluid power - Directional control valves - Measurement of shifting time" defines standardized test procedures for measuring the shifting time of electrically or p…
ISO 6358-1:2013/Amd 1:2020
ДействующийPneumatic fluid power — Determination of flow-rate characteristics of components using compressible fluids —…
Overview ISO 6358-1:2013/Amd 1:2020 is an important amendment to the ISO 6358-1:2013 standard, developed by the International Organization for Standardization (ISO). This document focuses on pneumati…
SIST EN ISO 6338:2026
ДействующийMethod to calculate GHG emissions at LNG plant (ISO 6338:2023)
Overview SIST EN ISO 6338:2026 / ISO 6338:2023 establishes a standardized method for calculating greenhouse gas (GHG) emissions at liquefied natural gas (LNG) plants, both onshore and offshore. Devel…
SIST-TP CEN ISO/ASTM TR 52958:2026
Additive manufacturing of metals - Powder bed fusion (PBF) - In-situ coaxial photodiode monitoring for lack o…
Overview SIST-TP CEN ISO/ASTM TR 52958:2026 specifies a workflow for the detection of lack of fusion flaws during the additive manufacturing of metals using powder bed fusion-laser based (PBF-LB) pro…
SIST EN ISO 41002:2026
ДействующийFacility management - Development of the facility management organization (ISO 41002:2026)
Overview SIST EN ISO 41002:2026 - Facility management - Development of the facility management organization offers strategic guidance for building and developing robust facility management (FM) organ…
SIST EN ISO 844:2026
ДействующийRigid cellular plastics - Determination of compressive properties (ISO 844:2026)
Overview SIST EN ISO 844:2026 - Rigid Cellular Plastics: Determination of Compressive Properties (ISO 844:2026) provides standardized methods for measuring the compressive properties of rigid cellula…
SIST-TS CEN ISO/TS 17664-3:2026
ДействующийProcessing of health care products - Information to be provided by the medical device manufacturer for the pr…
Overview SIST-TS CEN ISO/TS 17664-3:2026 sets out comprehensive guidance for grouping reusable medical devices based on their cleaning requirements. This technical specification, prepared collaborati…
SIST EN ISO 8980-4:2026
ДействующийOphthalmic optics - Uncut finished spectacle lenses - Part 4: Specifications and test methods for the propert…
Overview SIST EN ISO 8980-4:2026 specifies requirements and test methods for the properties of anti-reflective coatings and hydrophobic coatings applied to uncut finished spectacle lenses. Developed…