SIST ISO 16000-30:2015 PDF
Indoor air - Part 30: Sensory testing of indoor air
Indoor air - Part 30: Sensory testing of indoor air
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 37
- Дата публикации:
- 5 марта 2015 г.
- ICS:
- 13.040.20
- Технический комитет:
- KAZ - Air quality
ISO 16000-30:2014 specifies sensory testing and the evaluation of indoor odours using human panels. Sensory testing can be performed on site or in laboratories; in the latter case, by means of air in sampling containers which were collected from the site. The olfactory testing is appropriate for office and administration buildings, assembly halls, residential buildings, and other habitable rooms in which the comfort and health of the occupants is of interest. The test criteria in ISO 16000-30:2014 specifies are not applicable to factory buildings and workshops or other rooms in which odours unavoidably stem from the production processes (kitchens, bakeries etc.). If an odour evaluation of such rooms is undertaken without the odour-producing processes, it is necessary to take into account that there is a possibility that the processes have influenced and changed the odour of the room through the adsorption of odorous compounds. Sensory odour tests of indoor air can meet a variety of objectives. These include finding the cause(s) of unpleasant or objectionable odours, determining the reasonability of odours and the usability of affected rooms, and inspecting the results of renovation work. When seeking the cause of odours, it is wise to conduct additional laboratory tests on samples of the component materials according to ISO 16000‑28. In the process of locating odour sources by means of olfactory tests, it is necessary to take into account the fact that the odour compounds can accumulate on other surfaces, which exacerbates the problem.
Abstract
Overview
SIST ISO 16000-30:2015 - "Indoor air - Part 30: Sensory testing of indoor air" specifies procedures for sensory (olfactory) testing and evaluation of indoor odours using human panels. The standard covers both on-site testing and laboratory evaluation of air samples collected in sampling containers. It is designed for assessing occupant comfort and indoor air quality (IAQ) in habitable spaces such as offices, residential buildings and assembly halls, and helps identify causes of objectionable odours and verify remedial actions.
Key topics and technical requirements
- Scope and limitations
- Applicable to buildings where occupant comfort and health are of interest; not intended for factories, workshops or rooms with unavoidable production odours (e.g., kitchens, bakeries).
- Notes the potential for odorous compounds to adsorb onto surfaces and affect results.
- Sensory methods
- Use of trained or untrained human panels for evaluating acceptability, intensity, hedonic tone (pleasantness), and odour quality.
- Testing performed on site or in a laboratory using air collected in sampling containers.
- Measurement planning
- Selection criteria for panel members, measuring points, testing situations and dates.
- Requirements for an odour-neutral recovery room for panelists and detailed testing logs.
- Sampling and documentation
- Procedures for sampling, transporting and presenting air samples; annexes include training procedures and example sampling/presentation devices.
- Interpretation and limitations
- Sensory tests assess perceived odour but do not determine chemical health hazards - the standard recommends complementary chemical analyses.
- Advises risk assessment to ensure no harmful compounds are present; in some jurisdictions ethics review may be required.
Practical applications - who uses this standard
- Indoor air quality (IAQ) consultants and environmental engineers performing olfactory investigations.
- Facility and property managers assessing occupant complaints or post-renovation air quality.
- Occupational hygienists and public health authorities evaluating building habitability.
- Architects, HVAC professionals, and building inspectors verifying effectiveness of ventilation and remediation measures.
- Typical uses: identifying odour sources, assessing reasonability/usability of rooms, validating renovation outcomes, and guiding follow-up chemical testing.
Related standards and guidance
- ISO 16000 series (other parts for sampling and chemical analysis)
- Particularly relevant: ISO 16000-28 (determination of odour emissions from building products) - recommended when identifying material sources.
Keywords: ISO 16000-30, indoor air, sensory testing, odour evaluation, olfactory testing, human panels, air sampling, indoor air quality (IAQ).
Технические детали
- SKU
- SIST ISO 16000-30:2015
Похожие стандарты
Упомянутые в описании и другие стандарты SIST
BS ISO 16000-22:2025
ДействующийIndoor air. Detection and quantification of fungal biomass by fungal beta-N-acetylhexosaminidase enzyme activ…
SIST ISO 16000-28:2021
ДействующийIndoor air - Part 28: Determination of odour emissions from building products using test chambers
Overview SIST ISO 16000-28:2021 - "Indoor air - Part 28: Determination of odour emissions from building products using test chambers" specifies a laboratory method and evaluation procedures for measu…
SIST EN ISO 6338:2026
ДействующийMethod to calculate GHG emissions at LNG plant (ISO 6338:2023)
Overview SIST EN ISO 6338:2026 / ISO 6338:2023 establishes a standardized method for calculating greenhouse gas (GHG) emissions at liquefied natural gas (LNG) plants, both onshore and offshore. Devel…
SIST-TP CEN ISO/ASTM TR 52958:2026
Additive manufacturing of metals - Powder bed fusion (PBF) - In-situ coaxial photodiode monitoring for lack o…
Overview SIST-TP CEN ISO/ASTM TR 52958:2026 specifies a workflow for the detection of lack of fusion flaws during the additive manufacturing of metals using powder bed fusion-laser based (PBF-LB) pro…
SIST EN ISO 41002:2026
ДействующийFacility management - Development of the facility management organization (ISO 41002:2026)
Overview SIST EN ISO 41002:2026 - Facility management - Development of the facility management organization offers strategic guidance for building and developing robust facility management (FM) organ…
SIST EN ISO 844:2026
ДействующийRigid cellular plastics - Determination of compressive properties (ISO 844:2026)
Overview SIST EN ISO 844:2026 - Rigid Cellular Plastics: Determination of Compressive Properties (ISO 844:2026) provides standardized methods for measuring the compressive properties of rigid cellula…
SIST-TS CEN ISO/TS 17664-3:2026
ДействующийProcessing of health care products - Information to be provided by the medical device manufacturer for the pr…
Overview SIST-TS CEN ISO/TS 17664-3:2026 sets out comprehensive guidance for grouping reusable medical devices based on their cleaning requirements. This technical specification, prepared collaborati…
SIST EN ISO 8980-4:2026
ДействующийOphthalmic optics - Uncut finished spectacle lenses - Part 4: Specifications and test methods for the propert…
Overview SIST EN ISO 8980-4:2026 specifies requirements and test methods for the properties of anti-reflective coatings and hydrophobic coatings applied to uncut finished spectacle lenses. Developed…