SIST ISO 6588-2:2023 PDF
Paper, board and pulps - Determination of pH of aqueous extracts - Part 2: Hot extraction
Paper, board and pulps - Determination of pH of aqueous extracts - Part 2: Hot extraction
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 12
- Дата публикации:
- 9 июня 2023 г.
- Издание:
- ISO IS 6588 edition 4 version 1
- ICS:
- 85.040
This document specifies a method for the determination of the pH-value defined by the electrolytes extractable by hot water from a sample of paper, board or pulp. This document is applicable to all kinds of paper, board and pulp. As the quantity of extractable ionic material approaches zero, as in the case of highly purified pulps, the precision of the method becomes poor because of the difficulties encountered in making pH measurements on water containing little electrolytic material. Since the extraction in this document is performed with distilled or deionised water, the pH-value measured can sometimes be different (e.g. fully bleached pulp) from the pH-value measured under mill process conditions in which various types of process waters, such as chemically treated river water containing electrolytes, are used. In such cases, ISO 29681 can be used instead, as it is specifically applicable to bleached pulps from virgin fibres and to pulp samples having a low ionic strength for which the pH value gives more realistic results related to mill conditions than those obtained with this document. For cellulosic papers used for electrical purposes, the method used can be that given in IEC 60554-2[5].
Abstract
Overview
ISO 6588-2:2021 specifies a laboratory method for determining the pH of aqueous extracts obtained by hot water extraction from samples of paper, board and pulp. Known as the “hot extraction” pH test, the standard defines sample preparation, extraction, filtration, conditioning of the extract and pH measurement conditions so that results are comparable between laboratories and suitable for quality control, R&D and regulatory records.
Key topics and technical requirements
- Scope: Applicable to all kinds of paper, board and pulp. Note limitations for very low ionic-strength (highly purified) pulps where precision becomes poor.
- Extraction principle: Typical procedure uses 2.0 g ±0.1 g air-dry sample extracted with 100 ml boiling distilled/deionised water under reflux for 1 h ±5 min.
- Post-extraction handling: Cool to 20–25 °C, filter (fritted glass), add 2 ml of 1 M KCl to stabilise the ionic strength, then measure pH.
- Reagents and water quality: Distilled or deionised water with conductivity ≤ 0.1 mS/m after boiling; water pH about 6.8–7.3. Use standard buffer solutions (pH ~4, 7 and 9) for calibration.
- Equipment: Chemically resistant glassware (reflux condenser, fritted filter), and a pH meter (combined or separate glass and reference electrodes) readable to at least 0.05 pH unit.
- Measurement and reporting:
- Calibrate pH meter at 20–25 °C with two buffer points bracketing the expected pH.
- Run duplicate extractions; report the mean to the nearest 0.1 pH unit.
- Individual duplicates should not differ by more than 0.2 pH unit; otherwise perform two additional determinations and report mean and range.
- Quality checks: Re-check electrode performance after measurement; buffers should agree within 0.1 pH unit.
Practical applications and users
ISO 6588-2:2021 is used for:
- Quality control in pulp and paper mills (monitoring acidity/alkalinity of products).
- Incoming materials inspection and supplier compliance testing.
- Laboratory R&D assessing finishing additives, bleaching effects or contamination.
- Regulatory documentation and specification verification for packaging and archival papers.
Typical users include mill laboratories, independent testing labs, paper manufacturers, suppliers of pulp and chemicals, and standards/compliance teams.
Related standards
- ISO 6588-1 - cold extraction variant (different extraction conditions).
- ISO 29681 - hot extraction with added salt (preferred for bleached or very low ionic-strength pulps to simulate mill conditions).
- ISO 186 and ISO 7213 - sampling standards referenced for representative sampling.
- IEC 60554-2 - alternative pH method for cellulosic papers used in electrical applications.
Keywords: ISO 6588-2:2021, pH determination, hot extraction, paper testing, pulp testing, aqueous extracts, quality control, laboratory method.
Технические детали
- Технический комитет
- VPK - Pulp, paper, board and products
- SKU
- SIST ISO 6588-2:2023
Похожие стандарты
Стандарты, упомянутые в описании
ISO 6588-2:2021
ДействующийPaper, board and pulps — Determination of pH of aqueous extracts — Part 2: Hot extraction
Overview ISO 6588-2:2021 specifies a laboratory method for determining the pH of aqueous extracts obtained by hot water extraction from samples of paper, board and pulp. Known as the “hot extraction”…
SIST ISO 6588-1:2023
ДействующийPaper, board and pulps - Determination of pH of aqueous extracts - Part 1: Cold extraction
Overview Standard Reference: ISO 6588-1:2021 Title: Paper, board and pulps - Determination of pH of aqueous extracts - Part 1: Cold extraction ISO 6588-1:2021 specifies a laboratory method to determi…
ISO 2968:1981
ОтменёнCinematography — Recorded characteristics for magnetic sound record on 8 mm Type S motion- picture prints and…
BS ISO 18692-1:2026
ДействующийFibre ropes for offshore stationkeeping. General specification.
SIST EN ISO 7213:2022
ДействующийPulps - Sampling for testing (ISO 7213:2021)
Overview SIST EN ISO 7213:2022 is an international standard developed by ISO/TC 6 in collaboration with CEN/TC 172, specifying a method for sampling pulp-delivered in bales or rolls-to obtain a gross…
IEC 60554-2:2001
ДействующийCellulosic papers for electrical purposes - Part 2: Methods of test
Overview IEC 60554-2:2001 is an international standard developed by the International Electrotechnical Commission (IEC) that specifies the methods of testing cellulosic papers for electrical purposes…