SIST ISO 6589:1996 PDF
Joints in building -- Laboratory method of test for air permeability of joints
Joints in building -- Laboratory method of test for air permeability of joints
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 3
- Дата публикации:
- 1 декабря 1996 г.
- ICS:
- 91.060.99
- Технический комитет:
- ISS SPL.GPO - Building construction
Specifies the test method to be used in laboratories for assessing the air permeability of non-opening joints between components in the exterior walls of buildings, whether the joints have been subjected to prior ageing or not. Does not apply to joints within components (for example the joint between glass fixed in a window frame and sealed with a glazing compound).
Abstract
Overview
SIST ISO 6589:1996 specifies a laboratory test method for assessing the air permeability of non-opening joints in the exterior walls of buildings. Developed by the International Organization for Standardization (ISO) Technical Committee ISO/TC 59 on Building Construction, this standard provides a controlled procedure for evaluating the resistance of joints to the passage of air under differential pressure conditions. It covers joints between components fixed according to manufacturers' recommendations and addresses joints both with and without prior ageing treatment.
The standard is essential for ensuring building envelope airtightness, improving thermal efficiency, and minimizing energy loss due to air infiltration. It does not apply to joints within components (e.g., glass fixed in a window frame sealed with glazing compound) but focuses on the joints between components in the external wall structure.
Key Topics
-
Scope and Application SIST ISO 6589:1996 applies to exterior wall joints between building components, crucial for air infiltration control. It excludes joints inside components but includes joints between glass and fixed window frames on site.
-
Test Methodology The test simulates real-world conditions by subjecting the joint specimen to both positive and negative differential pressures within a sealed, pressurizable chamber. Pressures range typically from 50 Pa up to 600 Pa, or higher if required, applied in controlled increments.
-
Test Setup and Apparatus The essential equipment includes:
- A sealed chamber large enough to house at least 1 meter of joint length.
- Devices to impose and control differential pressure across the joint.
- Airflow metering equipment to measure air leakage.
- Instruments for measuring differential pressure and rapid pressure changes.
-
Preparation and Installation The joint must be installed between actual components representing realistic conditions and able to sustain the imposed pressures without deformation that might affect performance. Both nominal and tolerance variations in joint width and alignment are tested.
-
Measurement and Reporting Air permeability is expressed in cubic metres per hour per metre of joint length and plotted against differential pressure. Test reports must include detailed descriptions of the apparatus, test conditions, specimen, simulated ageing performed (if any), and the resulting air permeability data.
Applications
-
Building Envelope Design Ensuring effective sealing of joints in exterior walls to improve overall airtightness contributes to energy efficiency, indoor comfort, and building durability.
-
Quality Control and Assurance Manufacturers and building professionals use the standard to verify the performance of joint systems before installation, ensuring compliance with energy codes and performance requirements.
-
Material and Joint System Development The air permeability test supports research and development of joint materials and sealants, particularly their resistance to air leakage after ageing or environmental exposure.
-
Assessment of Building Retrofit Solutions When upgrading building envelopes, testing existing or new joint solutions in the lab supports selecting effective retrofit materials that maintain airtightness.
Related Standards
-
ISO 2444: Joints in Building - Vocabulary Provides key definitions related to building joints that support understanding and consistency in testing standards.
-
ISO 3447: Joints in Building - General Check-list of Joint Functions Outlines the functional requirements that joints must satisfy, providing a basis for testing the key aspects such as air permeability.
-
ISO 6613: Windows and Door Height Windows - Air Permeability Test Addresses air permeability testing for windows and doors, complementing ISO 6589’s focus on building joints outside of components.
Keywords: ISO 6589, air permeability test, building joints, exterior walls, laboratory test method, airtightness, differential pressure, joint air leakage, building envelope, construction standards, energy efficiency, joint performance testing, simulated ageing, exterior wall components.
Технические детали
- SKU
- SIST ISO 6589:1996
Похожие стандарты
Стандарты, упомянутые в описании
ISO 24444:2019/Amd 1:2022
ДействующийCosmetics — Sun protection test methods — In vivo determination of the sun protection factor (SPF) — Amendmen…
Overview ISO 24444:2019/Amd 1:2022 is an important amendment to the internationally recognized standard for testing sun protection in cosmetics. Developed by ISO Technical Committee ISO/TC 217 in col…
SIST ISO 3447:1996
ДействующийJoints in building -- General check-list of joint functions
Overview SIST ISO 3447:1996 - Joints in Building: General Check-list of Joint Functions is an international standard developed by SIST. It provides a comprehensive, general checklist of functions tha…
BS ISO 6613:2023
ДействующийWindows and doors. Air permeability. Test method
1 Scope This document specifies the test method to determine the air permeability of completely assembled windows and pedestrian door sets of any material, when exposed to positive or negative test p…