Workplace air - Determination of particulate lead and lead compounds - Flame and electrothermal atomic absorption spectrometric methods
Workplace air - Determination of particulate lead and lead compounds - Flame and electrothermal atomic absorption spectrometric methods
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 37
- Дата публикации:
- 18 августа 2023 г.
- ICS:
- 13.040.30
- Технический комитет:
- KAZ - Air quality
This document specifies flame and electrothermal atomic absorption spectrometric methods for the determination of the time-weighted average mass concentration of particulate lead and lead compounds in workplace air. These methods are typically applicable to personal sampling of the inhalable fraction of airborne particles, as defined in ISO 7708, and to static (area) sampling. It can be applied to other health-related fractions as required. The sample dissolution procedure specifies hot plate or microwave assisted digestion, or ultrasonic extraction (see 11.2). The use of an alternative, more vigorous dissolution procedure is necessary when it is desired to extract lead from compounds present in the test atmosphere that are insoluble using the dissolution procedures described herein (see Clause 5). The flame atomic absorption method is applicable to the determination of masses of approximately 1 µg to 200 µg of lead per sample, without dilution[1]. The electrothermal atomic absorption method is applicable to the determination of masses of approximately 0,01 µg to 0,5 µg of lead per sample, without dilution[1]. The ultrasonic extraction procedure has been validated for the determination of masses of approximately 20 µg to 100 µg of lead per sample, for laboratory-generated lead fume air filter samples[2]. The concentration range for lead in air for which this procedure is applicable is determined in part by the sampling procedure selected by the user (see 10.1).
Abstract
Overview
ISO 8518:2022 specifies validated laboratory procedures for measuring particulate lead and lead compounds in workplace air using flame and electrothermal atomic absorption spectrometric (AAS) methods. The standard covers sampling (personal and static/area), sample dissolution (hot-plate digestion, microwave-assisted digestion, or ultrasonic extraction), instrumental analysis, detection capability ranges, and quality control for time-weighted average (TWA) mass concentrations of inhalable particles (per ISO 7708) and other health-related fractions as needed.
Key topics and requirements
- Scope and purpose: Determination of TWA mass concentration of particulate lead and lead compounds in workplace atmospheres for occupational exposure assessment.
- Sampling types: Personal sampling of the inhalable fraction and static (area) sampling; guidance on sampler selection, sampling position, flow rate, blanks, transport and storage.
- Sample dissolution options:
- Hot-plate digestion
- Microwave-assisted digestion
- Ultrasonic extraction (validated for laboratory-generated lead-fume filter samples at approx. 20 µg to 100 µg lead per sample)
- Use a more vigorous dissolution if target lead compounds are insoluble with the listed procedures.
- Analytical methods:
- Flame AAS - suitable for approximately 1 µg to 200 µg lead per sample (without dilution).
- Electrothermal AAS - suitable for approximately 0.01 µg to 0.5 µg lead per sample (without dilution).
- Measurement strategy: Guidance on assessment strategy, selection of measurement conditions (screening, worst-case, periodic measurements), and how sampling choice affects applicable air concentration range.
- Quality assurance: Reagent/media blanks, spiked samples and duplicates, certified reference materials, external quality assessment, and determination of instrumental/method detection and quantification limits.
- Special considerations: Treatment of sampler wall deposits (informative Annex B), temperature/pressure corrections, and reporting requirements.
Applications and users
ISO 8518:2022 is intended for:
- Industrial hygienists and occupational health professionals conducting workplace air monitoring for lead exposure.
- Analytical laboratories performing trace metal analysis of air filter samples.
- Regulatory and enforcement agencies assessing compliance with occupational exposure limits.
- Employers in industries with potential lead exposure (mining, metal refining, battery manufacture, construction) to verify control measures.
Practical benefits include standardized workflows for sample preparation and AAS analysis, defined detection ranges for method selection, and QA practices that improve comparability and legal defensibility of exposure data.
Related standards
Технические детали
- SKU
- SIST ISO 8518:2023
Похожие стандарты
Упомянутые в описании и другие стандарты SIST
ISO 8518:2022
ДействующийWorkplace air — Determination of particulate lead and lead compounds — Flame and electrothermal atomic absorp…
Overview ISO 8518:2022 specifies validated laboratory procedures for measuring particulate lead and lead compounds in workplace air using flame and electrothermal atomic absorption spectrometric (AAS…
SIST ISO 7708:1997
ДействующийAir quality - Particle size fraction definitions for health-related sampling
Overview ISO 7708:1995 - "Air quality - Particle size fraction definitions for health-related sampling" defines internationally accepted sampling conventions for airborne particle size fractions used…
SIST EN ISO 6338:2026
ДействующийMethod to calculate GHG emissions at LNG plant (ISO 6338:2023)
Overview SIST EN ISO 6338:2026 / ISO 6338:2023 establishes a standardized method for calculating greenhouse gas (GHG) emissions at liquefied natural gas (LNG) plants, both onshore and offshore. Devel…
SIST-TP CEN ISO/ASTM TR 52958:2026
Additive manufacturing of metals - Powder bed fusion (PBF) - In-situ coaxial photodiode monitoring for lack o…
Overview SIST-TP CEN ISO/ASTM TR 52958:2026 specifies a workflow for the detection of lack of fusion flaws during the additive manufacturing of metals using powder bed fusion-laser based (PBF-LB) pro…
SIST EN ISO 41002:2026
ДействующийFacility management - Development of the facility management organization (ISO 41002:2026)
Overview SIST EN ISO 41002:2026 - Facility management - Development of the facility management organization offers strategic guidance for building and developing robust facility management (FM) organ…
SIST EN ISO 844:2026
ДействующийRigid cellular plastics - Determination of compressive properties (ISO 844:2026)
Overview SIST EN ISO 844:2026 - Rigid Cellular Plastics: Determination of Compressive Properties (ISO 844:2026) provides standardized methods for measuring the compressive properties of rigid cellula…
SIST-TS CEN ISO/TS 17664-3:2026
ДействующийProcessing of health care products - Information to be provided by the medical device manufacturer for the pr…
Overview SIST-TS CEN ISO/TS 17664-3:2026 sets out comprehensive guidance for grouping reusable medical devices based on their cleaning requirements. This technical specification, prepared collaborati…
SIST EN ISO 8980-4:2026
ДействующийOphthalmic optics - Uncut finished spectacle lenses - Part 4: Specifications and test methods for the propert…
Overview SIST EN ISO 8980-4:2026 specifies requirements and test methods for the properties of anti-reflective coatings and hydrophobic coatings applied to uncut finished spectacle lenses. Developed…