BS ISO 27186:2010
Active implantable medical devices. Four-pole connector system for implantable cardiac rhythm management devices. Dimensional and test requirements
Active implantable medical devices. Four-pole connector system for implantable cardiac rhythm management devices. Dimensional and test requirements
- Статус документа:
- Отменён
- Формат:
- Электронный (PDF)
- Дата публикации:
- 31 августа 2013 г.
- ICS:
- 11.040.40
- SKU:
- BS ISO 27186:2010
Abstract
1 Scope This International Standard specifies a four-pole connector system for implantable cardiac rhythm management devices which have pacing, electrogram sensing and/or defibrillation functions. This International Standard includes requirements for the connector portion of an implantable lead as well as for the mating connector cavity attached to an implantable pulse generator . Essential dimensions and performance requirements are specified together with appropriate test methods. This International Standard is not intended to replace or provide alternatives for unipolar or bipolar connector standards that currently exist (such as ISO 11318 and ISO 5841-3). This International Standard is not applicable to high voltage systems with intended outputs greater than 1 000 V and/or 50 A. This International Standard is not applicable to systems which include sensors or unique electrodes that are not capable of conventional pacing, electrogram sensing and/or defibrillation functions. This International Standard does not specify all connector features. It does not address all aspects of functional compatibility, safety or reliability of leads and pulse generators assembled into a system.
NOTE Lead and pulse generator connector systems not conforming to this International Standard might be safe and reliable, and might have clinical advantages.
Похожие стандарты
Упомянутые в описании и другие стандарты BS
ISO 11318:2002
ДействующийCardiac defibrillators — Connector assembly DF-1 for implantable defibrillators — Dimensions and test require…
Overview ISO 11318:2002 - Cardiac defibrillators - Connector assembly DF‑1 for implantable defibrillators - Dimensions and test requirements specifies the DF‑1 unipolar connector assembly used to con…
ISO 5841-3:2013
ДействующийImplants for surgery — Cardiac pacemakers — Part 3: Low-profile connectors (IS-1) for implantable pacemakers
Overview ISO 5841-3:2013 - "Implants for surgery - Cardiac pacemakers - Part 3: Low-profile connectors (IS-1) for implantable pacemakers" defines the form and fit of the IS-1 connector assembly used…
BS ISO 10835:2007
ДействующийDirect reduced iron and hot briquetted iron. Sampling and sample preparation.
1 Scope This International Standard gives a) the underlying theory, b) the basic principles for sampling and preparation of samples , and c) the basic requirements for the design, installation and op…