IEC 60076-19-1:2023
Power transformers - Part 19 - 1: Rules for the determination of uncertainties in the measurement of the losses of power transformers
Power transformers - Part 19 - 1: Rules for the determination of uncertainties in the measurement of the losses of power transformers
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 97
- Дата публикации:
- 23 мая 2023 г.
- Издание:
- IEC IS 60076 edition 1 version 1
- ICS:
- 29.180
IEC 60076-19-1:2023 defines the procedures that are applied to evaluate the uncertainty affecting the measurements of no-load and load losses during the routine tests on power transformers. This document centres on measuring systems utilizing digital instruments, although the procedures can be adapted to evaluation of systems with analogue instruments where further uncertainty sources have to be taken into account. This document specifies how to determine measurement uncertainty and how to apply corrections for known errors in the measurement chain. Information vis-à-vis judgement and traceability are given in IEC 60076-8:1997, 10.1 and 10.2.
Abstract
Overview
IEC 60076-19-1:2023 is an international standard published by the International Electrotechnical Commission (IEC) that provides comprehensive rules for determining the uncertainties in the measurement of losses in power transformers. This standard is crucial for ensuring accurate and reliable assessment of both no-load and load losses during routine tests on power transformers. It is primarily focused on digital measurement systems but also allows for adaptation to analogue systems, where additional sources of uncertainty must be considered.
Accurate loss measurement is essential in the power transformer industry, influencing contractual obligations, investments, regulatory compliance, and market surveillance. The standard details procedures for evaluating all uncertainties associated with measurement results and defines corrective actions for known errors, supporting data integrity and traceability as per global best practices.
Key Topics
-
Measurement Uncertainty Evaluation
- Defines how to estimate uncertainties in no-load and load loss measurements.
- Provides guidance for measurement systems using digital and analogue instruments.
- Includes model functions for uncertainty calculation by combining both the test equipment and transformer characteristics.
-
Correction for Systematic Deviations
- Outlines procedures to identify and correct known systematic errors within measurement chains.
- If systematic errors cannot be corrected, the standard stipulates their inclusion as additional sources of uncertainty.
-
Traceability and Calibration
- Stresses the importance of using traceably-calibrated measuring equipment.
- Explains the role of calibration certificates and documented, unbroken calibration chains for ensuring measurement integrity.
-
Uncertainty Budgeting and Reporting
- Specifies methods for calculating combined standard and expanded uncertainties.
- Provides templates for reporting measurement results along with their associated uncertainties, maintaining transparency and quality assurance.
-
Application to Various Testing Scenarios
- Procedures are suitable not only for type and routine testing but also for prequalification of test facilities, technical enquiries, manufacturer acceptance, and market surveillance.
Applications
IEC 60076-19-1:2023 is widely applicable across the transformer manufacturing, testing, and regulatory sectors:
-
Power Transformer Manufacturers
- Ensures reliable and standardized assessment of transformer losses, supporting compliance with contractual guarantees and market regulations (such as the EU Ecodesign Directive).
-
Testing Laboratories and Quality Control
- Enables laboratories to provide reliable uncertainty evaluations, bolstering the credibility of their measurement results.
- Supports adherence to ISO/IEC 17025 requirements for measurement uncertainty.
-
Certification and Inspection Bodies
- Offers procedures for ensuring transformer loss measurements meet international standards, enabling accurate certification and market surveillance activities.
-
Customers and End Users
- Allows purchasers to understand the precision and reliability of loss measurements reported by suppliers, supporting informed procurement and operational decisions.
Related Standards
IEC 60076-19-1:2023 references and complements several key international standards, including:
- IEC 60076-1: Power transformers - Part 1: General – Specifies general requirements for power transformers and routine test procedures.
- IEC 60076-2: Power transformers - Part 2: Temperature rise for liquid-immersed transformers – Details temperature measurement protocols.
- IEC 60076-8: Power transformers - Part 8: Application guide – Provides background on test result interpretation, uncertainty, and traceability.
- IEC 60076-11: Power transformers - Part 11: Dry-type transformers – Covers measurement procedures for dry-type units.
- ISO/IEC 17025: General requirements for the competence of testing and calibration laboratories – Referenced for uncertainty evaluation methods.
- ISO/IEC Guide 98-3: Uncertainty of measurement – Guidance on general principles for measurement uncertainty.
Practical Value
Implementing IEC 60076-19-1:2023 enables organizations to:
- Enhance measurement accuracy and confidence in reported transformer losses.
- Meet international regulatory requirements and contractual obligations.
- Demonstrate robust quality assurance through traceable, calibrated measurement systems.
- Support market competitiveness by adhering to state-of-the-art testing methodologies.
By following this standard, stakeholders ensure their power transformer loss measurement processes are transparent, internationally recognized, and fully documented, leading to increased trust and reliability in the global transformer industry.
Технические детали
- Технический комитет
- TC 14 - Power transformers
- SKU
- IEC 60076-19-1:2023
Похожие стандарты
Стандарты, упомянутые в описании
BS EN ISO/IEC 17025:2017
ДействующийGeneral requirements for the competence of testing and calibration laboratories.
IEC 60076-18:2012
ДействующийPower transformers - Part 18: Measurement of frequency response
IEC 60076-18:2012 Overview IEC 60076-18:2012 titled "Power transformers - Part 18: Measurement of frequency response" is an international standard developed by the International Electrotechnical Comm…
IEC 60076-25:2023
ДействующийPower transformers - Part 25: Neutral grounding resistors
Overview IEC 60076-25:2023 is an international standard developed by the International Electrotechnical Commission (IEC) outlining the requirements for dry type, natural air-cooled neutral grounding…
IEC 60076-8:1997
ДействующийPower transformers - Part 8: Application guide
Overview IEC 60076-8:1997 - Power transformers: Application guide is an IEC guidance document for users of power transformers complying with the IEC 60076 series. It replaces IEC 60606 and provides p…
IEC 60076-11:2018
ДействующийPower transformers - Part 11: Dry-type transformers
Overview IEC 60076-11:2018 - Power transformers Part 11: Dry-type transformers - is the international standard that defines design, rating, testing and performance requirements for dry-type power tra…