IEC 60076-25:2023
Power transformers - Part 25: Neutral grounding resistors
Power transformers - Part 25: Neutral grounding resistors
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 46
- Дата публикации:
- 23 февраля 2023 г.
- Издание:
- IEC IS 60076 edition 1 version 1
- ICS:
- 29.180
IEC 60076-25:2023 applies to dry type natural air-cooled resistors, for neutral grounding of transformers and generators, in order to limit the earth fault current in power systems by means of metallic resistive elements. For the purposes of this document, the resistor can be: used alone or in combination with other electrotechnical products not covered by this document, such as (but not limited to): a step-down single-phase transformer, an open triangle or zig-zag transformer (where the neutral point is not available) and a Petersen coil reactor (in order to increase active power contribution to the fault or reduce time constant for proper protection operation or both); designed, manufactured and verified on a one-off basis or fully standardized and manufactured in quantity. Both terms "neutral grounding resistor" (NGR) and "neutral earthing resistor" (NER) can be used. However, for the purposes of this document and in order to avoid any confusion with "neutral earthing reactor" (NER), the term "neutral grounding resistor" (NGR) is used. This document specifies: the characteristics of the NGR; the service conditions requirements for NGRs; the tests and test methods for confirming that these conditions have been met; the requirements relating to marking for NGRs. Annex A provides guidance on how to consider the effect of resistance variation with temperature.
Abstract
Overview
IEC 60076-25:2023 is an international standard developed by the International Electrotechnical Commission (IEC) outlining the requirements for dry type, natural air-cooled neutral grounding resistors (NGRs) used in the neutral grounding of transformers and generators. The purpose of this standard is to ensure NGRs reliably limit earth fault current in power systems through carefully designed metallic resistive elements. This part of the IEC 60076 series specifies the characteristics, service conditions, testing procedures, and marking requirements for NGRs, providing clear guidance for manufacturers, installers, and users involved in modern power infrastructure.
Key Topics
-
Scope and Purpose:
IEC 60076-25:2023 applies specifically to dry type natural air-cooled resistors used for neutral grounding, limiting earth fault currents and enhancing the integrity and protection of power systems. -
Types of Application:
- NGRs may be used standalone or in conjunction with other electrotechnical equipment such as step-down single-phase transformers, open triangle or zig-zag transformers, and Petersen coil reactors, particularly where the neutral point is unavailable.
- Can be custom-designed for unique installations or standardized for serial production.
-
Service Conditions:
- Standard ambient temperature is 20°C unless specified otherwise.
- Altitude correction is required for installations above 1,000 meters, as referenced in IEC 60071-2.
-
Ratings and Design Requirements:
- Parameters such as rated resistance, voltage, current (both short time and continuous), frequency, and insulation level are specified, ensuring the NGR meets specific installation requirements.
- The design addresses physical robustness, dielectric strength, proper ventilation, corrosion protection, and safe handling.
-
Testing and Compliance:
- Routine, type, and special tests verify safety, functionality, and durability.
- Test procedures cover visual inspection, resistance measurement, dielectric withstand, insulation resistance, temperature rise, and environmental protection (IP rating, etc.).
- Annex A provides guidance on resistance variation due to temperature to assist with effective system and protection coordination.
-
Product Marking:
- Mandatory nameplates must display critical technical and identification information for safe installation and long-term maintenance.
Applications
Neutral grounding resistors are essential in modern medium and high voltage power systems for:
-
Limiting Earth Fault Currents:
NGRs prevent excessive fault currents through transformer or generator neutrals, thus avoiding equipment damage and enhancing personnel safety. -
Coordination with Protection Systems:
By managing fault current levels and their duration, NGRs support timely and accurate operation of protective relays and isolation devices. -
Power System Stability:
Utilization with delta/zig-zag transformer banks or Petersen coils further tailors system grounding to reduce transient over-voltages and enhance network reliability. -
Versatile Deployment:
- Suitable for installations in substations, generation plants, and industrial environments.
- Standard ensures compatibility with varying system voltages, installation climates, and fault management strategies.
Related Standards
To ensure complete compliance in power transformer projects, IEC 60076-25:2023 should be used in conjunction with other key standards:
- IEC 60076-1: Power transformers - General
- IEC 60076-3: Insulation levels, dielectric tests and external clearances in air
- IEC 60060-1: High voltage test techniques
- IEC 60071-2: Insulation coordination - Application guidelines
- IEC 60529: Degrees of protection provided by enclosures (IP Code)
- IEC 60664-1: Insulation coordination for equipment within low-voltage systems (for system voltages below 1,000 V)
- IEC 62271-1: High-voltage switchgear and controlgear
IEC 60076-25:2023 advances best practices throughout the power industry by ensuring neutral grounding resistors are designed, tested, and implemented according to internationally recognized criteria for safety, reliability, and long lifecycle in evolving energy networks.
Технические детали
- Технический комитет
- TC 14 - Power transformers
- SKU
- IEC 60076-25:2023
Похожие стандарты
Стандарты, упомянутые в описании
IEC 60076-4:2002
ДействующийPower transformers - Part 4: Guide to the lightning impulse and switching impulse testing - Power transformer…
Overview IEC 60076-4:2002 - "Power transformers - Part 4: Guide to the lightning impulse and switching impulse testing - Power transformers and reactors" is an IEC guidance standard that supplements…
IEC 60071-2:2018
ДействующийInsulation co-ordination - Part 2: Application guidelines
Overview - IEC 60071-2:2018 (Insulation co‑ordination - Part 2: Application guidelines) IEC 60071-2:2018 provides practical application guidance for insulation co‑ordination in three‑phase electrical…
IEC 60076-18:2012
ДействующийPower transformers - Part 18: Measurement of frequency response
IEC 60076-18:2012 Overview IEC 60076-18:2012 titled "Power transformers - Part 18: Measurement of frequency response" is an international standard developed by the International Electrotechnical Comm…
IEC 60060-1:2025
ДействующийHigh-voltage test techniques - Part 1: General terminology and test requirements
Overview IEC 60060-1:2025, titled High-voltage test techniques – Part 1: General terminology and test requirements, is an updated international standard published by the International Electrotechnica…
IEC PAS 61076-3-109:2001
ОтменёнConnectors for electronic equipment - Part 3-109: Detail specification for two-part cable to board connector…
IEC 60664-1:2007
ДействующийInsulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests
Overview IEC 60664-1:2007 is an international standard published by the International Electrotechnical Commission (IEC) that defines the principles, requirements, and tests for insulation coordinatio…
IEC 62271-112:2013
ДействующийHigh-voltage switchgear and controlgear - Part 112: Alternating current high-speed earthing switches for seco…
Overview IEC 62271-112:2013 sets international requirements for high-voltage switchgear, specifically focusing on alternating current high-speed earthing switches (HSES) used for secondary arc extinc…