IEC 60079-13:2017
Explosive atmospheres - Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v"
Explosive atmospheres - Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v"
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 35
- Дата публикации:
- 22 мая 2017 г.
- Издание:
- IEC IS 60079 edition 2 version 1
- ICS:
- 29.260.20
IEC 60079-13:2017 gives requirements for the design, construction, assessment, verification and marking of rooms used to protect internal equipment: – located in a Zone 1 or Zone 2 or Zone 21 or Zone 22 explosive atmosphere without an internal source of gas/vapour release and protected by pressurization; – located in a Zone 2 explosive atmosphere with or without an internal source of gas/vapour release and protected by artificial ventilation; – located in a non-hazardous area, containing an internal source of gas/vapour release and protected by artificial ventilation; – located in a Zone 1 or Zone 2 or Zone 21 or Zone 22 explosive atmosphere containing an internal source of gas/vapour release and protected by both pressurization and artificial ventilation. The term "room" used in this document includes single rooms, multiple rooms, a complete building or a room contained within a building. A room is intended to facilitate the entry of personnel and includes inlet and outlet ducts. An acoustic hood and other like enclosures designed to permit the entry of personnel can be considered as a room. This document also includes requirements related safety devices and controls necessary to ensure that artificial ventilation, purging and pressurization is established and maintained. A room assembled or constructed on site, can be either on land or off-shore. The room is primarily intended for installation by an end-user but could be constructed and assessed at a manufacturer’s facility, where the final construction such as ducting can be completed on site. This document does not specify the methods that may be required to ensure adequate air quality for personnel with regard to toxicity and temperature within the room. National or other regulations and requirements may exist to ensure the safety of personnel in this regard. This second edition cancels and replaces the first edition published in 2010. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) modification of the title of this document to include artificially ventilated room "v" in addition to pressurized room "p"; b) addition of types of protection "pb", "pc", and "vc" and removal of types of protection "px", "py", "pz" and "pv"; c) definition of the differences between pressurization and artificial ventilation types of protection; d) removal of protection of rooms with an inert gas or a flammable gas from the scope of this document; e) addition of an informative annex to include examples of applications where types of protection pressurization or artificial ventilation or pressurization and artificial ventilation can be used and associated guidelines.
Abstract
Overview
IEC 60079-13:2017 - Explosive atmospheres - Part 13: Equipment protection by pressurized room "p" and artificially ventilated room "v" - gives requirements for the design, construction, assessment, verification and marking of rooms used to protect electrical and electronic equipment located in explosive atmospheres. The standard applies to single rooms, multi-room arrangements, whole buildings, acoustic hoods and similar enclosures that permit personnel entry and include inlet/outlet ducts. This is Edition 2.0 (2017) and represents a technical revision to the 2010 edition.
Key scope points:
- Protection of equipment inside rooms located in Zone 1/2 and Zone 21/22 explosive atmospheres using pressurization ("p"), artificial ventilation ("v"), or a combination of both.
- Rooms in non-hazardous areas that contain an internal source of gas/vapour release and are protected by artificial ventilation.
- Requirements for safety devices, control systems, purging, verification, marking and technical documentation.
Key topics and technical requirements
The standard addresses practical and technical elements necessary to achieve equipment protection in explosive atmospheres:
- Types of protection: Definitions and differences between pressurization ("p") and artificially ventilated ("v") rooms, and the introduced protection types such as pb, pc, vc.
- Design & construction: Room integrity, mechanical strength, penetrations, seals, personnel access doors, inlet/outlet ducts and HVAC considerations.
- Clean air supply: Sources of clean air, environmental conditions and integration with heating, ventilation and air conditioning systems.
- Pressurization-specific requirements: Pressurization systems, minimum pressure differentials, airlock arrangements, purging sequences, and actions on system failure.
- Artificial ventilation-specific requirements: Minimum flow rates, ventilation system design, safety actions for ventilation loss and purging procedures.
- Safety devices & controls: Gas detectors, safety interlocks, electrical disconnects, and verification of sequence of operations.
- Verification, testing & marking: Overpressure, purging, ventilation flow tests, confirmation of safety device ratings, marking and instruction documentation.
Practical applications and users
Who uses IEC 60079-13:
- Design and safety engineers specifying protective rooms for process plants, refineries, chemical and petrochemical facilities.
- Manufacturers and integrators of enclosures, acoustic hoods, packaged rooms, and modular onshore/offshore units.
- End‑users and facility operators implementing protected equipment rooms in Zones 1/2/21/22.
- Certification bodies, inspectors and maintenance teams responsible for verification, testing and periodic re‑assessment.
Typical applications:
- Enclosures for control and electrical equipment at gas turbine packages, pump skids, switchrooms, packaged plants and offshore modules where equipment must be isolated from surrounding explosive atmospheres.
Related standards
- IEC 60079 series (general explosive atmosphere standards) - consult IEC 60079-0 and other parts for complementary requirements, referenced normative documents and harmonized practices.
- National regulations on personnel air quality, toxicity and temperature may apply in addition to IEC 60079-13.
Технические детали
- Технический комитет
- SC 31J - Classification of hazardous areas and installation requirements
- SKU
- IEC 60079-13:2017
Похожие стандарты
Упомянутые в описании и другие стандарты IEC
IEC 60079-10-2:2026
ДействующийExplosive atmospheres - Part 10-2: Classification of areas - Explosive dust atmospheres
Overview IEC 60079-10-2:2026, published by the International Electrotechnical Commission (IEC), sets out guidelines for the identification and classification of areas where explosive dust atmospheres…
IEC 60079-0:2017
ДействующийExplosive atmospheres - Part 0: Equipment - General requirements
Overview IEC 60079-0:2017 - Explosive atmospheres - Part 0: Equipment - General requirements - sets the baseline general requirements for the construction, testing and marking of Ex Equipment and Ex…
IEC 62590-2-2:2026
ДействующийRailway applications - Electronic power converters for fixed installations - Part 2-2: DC Traction applicatio…
Overview IEC 62590-2-2:2026 is an international standard developed by the International Electrotechnical Commission (IEC) focusing on railway applications, specifically the electronic power converter…
IEC 61753-042-02:2026
ДействующийFibre optic interconnecting devices and passive components - Performance standard - Part 042-02: Plug-pigtail…
Overview IEC 61753-042-02:2026 establishes the minimum performance, test, and measurement requirements for plug-pigtail and plug-receptacle style OTDR (Optical Time-Domain Reflectometer) reflecting d…
IEC 61837-2:2018
ДействующийSurface mounted piezoelectric devices for frequency control and selection - Standard outlines and terminal le…
Overview IEC 61837-2:2018 - Surface mounted piezoelectric devices for frequency control and selection - Standard outlines and terminal lead connections - Part 2: Ceramic enclosures (Edition 3.0, 2018…
IEC 61851-23-1:2026
ДействующийElectric vehicle conductive charging system - Part 23-1: DC electric vehicle supply equipment - Automated con…
Overview IEC 61851-23-1:2026 is an international standard published by the International Electrotechnical Commission (IEC) that specifies requirements for DC electric vehicle supply equipment (EVSE)…
IEC 63506:2026
ДействующийCalibration of the prompt fission neutron logging tools
Overview IEC 63506:2026 - Calibration of the Prompt Fission Neutron Logging Tools is the international standard that specifies the calibration methods for prompt fission neutron (PFN) logging tools,…
IEC 63589-1:2026
ДействующийLinear accelerator - Electron linear accelerator for radiation processing - Part 1: General requirements and…
Overview IEC 63589-1:2026 specifies the general requirements and test methods for electron linear accelerator devices used in radiation processing. Developed by the International Electrotechnical Com…