IEC 60156:2018
Insulating liquids - Determination of the breakdown voltage at power frequency - Test method
Insulating liquids - Determination of the breakdown voltage at power frequency - Test method
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 60
- Дата публикации:
- 17 августа 2018 г.
- Издание:
- IEC IS 60156 edition 3 version 1
- ICS:
- 01
IEC 60156:2018 specifies the method for determining the dielectric breakdown voltage of insulating liquids at power frequency. The test procedure is performed in a specified apparatus, where the oil sample is subjected to an increasing AC electrical field until breakdown occurs. The method applies to all types of insulating liquids of nominal viscosity up to 350 mm2/s at 40 °C. It is appropriate both for acceptance testing on unused liquids at the time of their delivery and for establishing the condition of samples taken in monitoring and maintenance of equipment. This third edition cancels and replaces the second edition published in 1995. This edition constitutes a technical revision and, mainly, confirms the content of the previous edition even if some advances are included. The test method has not been changed for practical reason due to the very large number of instrumentation disseminated around the world, even if the use of stirring is now recommended.
Abstract
Overview
IEC 60156:2018 - Insulating liquids: Determination of the breakdown voltage at power frequency - Test method specifies a standardized laboratory procedure to determine the dielectric breakdown (AC breakdown) voltage of insulating liquids at power frequency. The method subjects an oil sample to a controlled, uniformly increasing AC electrical field in a specified test cell and records the voltage at which electrical breakdown occurs. The standard applies to insulating liquids with nominal viscosity up to 350 mm2/s at 40 °C and is intended for both acceptance testing of new liquids and condition assessment during monitoring and maintenance of electrical equipment. The 2018 (3rd) edition updates the 1995 edition mainly as a technical confirmation; the established test method remains, with stirring now recommended.
Key Topics and Requirements
- Scope and applicability: Covers all types of insulating liquids within the stated viscosity limit and for power-frequency testing.
- Test apparatus: Defines required electrical apparatus (voltage regulator, step-up transformer, switching system, current-limiting resistors, measuring device) and specified test cells and electrodes.
- Voltage control: Requires uniform, automatic rate of voltage rise using suitable regulators (electronic, autotransformer, etc.) and a low-harmonic AC source.
- Sample handling and preparation: Emphasizes rigorous sampling, temperature control and handling procedures for reproducible, certified results.
- Test procedure: Increasing AC field until breakdown; details on filling the cell, electrode preparation, and test reporting are included.
- Annexes: Includes informative annexes for an improved method (Annex A), low-volume sample cells (Annex B), and a reference material/performance check (Annex C).
- Reporting and reproducibility: Specifies required test data, dispersion expectations and reporting content for acceptance and monitoring purposes.
Applications and Who Uses IEC 60156:2018
- Power utilities and substations - routine monitoring of transformer and switchgear oils to detect contaminants (water, solids) and determine need for drying/filtration.
- Oil manufacturers and suppliers - acceptance testing of new insulating liquids prior to delivery.
- Test laboratories and OEMs - standardized dielectric testing for quality control and product characterization.
- Maintenance engineers and condition-monitoring teams - assessing oil condition after service, during refurbishment or before equipment filling.
Practical benefits include consistent, comparable breakdown-voltage results, support for maintenance decisions, and conformity with international testing practice for insulating liquid dielectric quality.
Related Standards
- IEC 60060 - High-voltage test techniques (general principles)
- IEC 60052 - Voltage measurement by means of sphere-gaps
- IEC 60475 - Method of sampling insulating liquids
- IEC 60060‑3 (referenced) - Performance verification and reference materials
Keywords: IEC 60156:2018, insulating liquids, breakdown voltage, power frequency, dielectric breakdown, oil testing, acceptance testing, monitoring and maintenance, test method.
Технические детали
- Технический комитет
- TC 10 - Fluids for electrotechnical applications
- SKU
- IEC 60156:2018
Похожие стандарты
Стандарты, упомянутые в описании
IEC 60060-1:2025
ДействующийHigh-voltage test techniques - Part 1: General terminology and test requirements
Overview IEC 60060-1:2025, titled High-voltage test techniques – Part 1: General terminology and test requirements, is an updated international standard published by the International Electrotechnica…
IEC 60052:2002
ДействующийVoltage measurement by means of standard air gaps
Overview IEC 60052:2002, titled Voltage Measurement by Means of Standard Air Gaps, is an international standard developed by the International Electrotechnical Commission (IEC). This third edition es…
IEC 60475:2011
ДействующийMethod of sampling insulating liquids
Overview IEC 60475:2011, titled Method of sampling insulating liquids, is an international standard published by the International Electrotechnical Commission (IEC). It defines standardized procedure…
IEC 60060-3:2006
ДействующийHigh-voltage test techniques - Part 3: Definitions and requirements for on-site testing
Overview IEC 60060-3:2006 - High-voltage test techniques - Part 3: Definitions and requirements for on-site testing - defines the terms, requirements and practical criteria for performing high-voltag…