IEC 60601-2-23:2011
Medical electrical equipment - Part 2-23: Particular requirements for the basic safety and essential performance of transcutaneous partial pressure monitoring equipment
Medical electrical equipment - Part 2-23: Particular requirements for the basic safety and essential performance of transcutaneous partial pressure monitoring equipment
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 95
- Дата публикации:
- 25 февраля 2011 г.
- Издание:
- IEC IS 60601 edition 3 version 1
- ICS:
- 11.040.55
IEC 60601-2-23:2011 applies to the basic safety and essential performance of transcutaneous partial pressure monitoring equipment. It applies to transcutaneous monitors used with adults, children and neonates, and it includes the use of these devices in foetal monitoring during birth. IEC 60601-2-23:2011 does not apply to haemoglobin saturation oximeters or to devices applied to surfaces of the body other than the skin (for example conjunctiva, mucosa). This third edition cancels and replaces the second edition published in 1999 and constitutes a technical revision. This edition of IEC 60601-2-23 was revised to align structurally with the 2005 edition of IEC 60601-1.
Abstract
Overview
IEC 60601-2-23:2011 is an international standard published by the International Electrotechnical Commission (IEC) specifying the basic safety and essential performance requirements for medical electrical equipment used in transcutaneous partial pressure monitoring. This particular standard focuses on transcutaneous monitors that measure the partial pressure of gases such as oxygen and carbon dioxide through the skin.
The scope includes devices used with adults, children, neonates, and extends to fetal monitoring during childbirth. Notably, this standard excludes haemoglobin saturation oximeters and devices applied on non-skin surfaces like conjunctiva or mucosa.
This third edition (2011) revises and replaces the 1999 edition, aligning the requirements structurally with the 2005 edition of IEC 60601-1, which covers general safety and performance requirements for medical electrical equipment.
Key Topics
- Basic safety requirements: Covering protection against electrical, mechanical, radiation, and temperature hazards related to transcutaneous partial pressure monitors.
- Essential performance criteria: Ensuring accuracy, reliability, and consistent performance of transcutaneous gas monitoring.
- Testing requirements: Normative references for verification of equipment functionality, including measurements, calibration, and performance under fault conditions.
- Alarm systems: Requirements and guidance on alarm functionality to alert caregivers to abnormal or hazardous conditions.
- Electromagnetic compatibility (EMC): Ensuring devices can operate safely in medical environments without interference from or causing electromagnetic disturbances.
- Marking and documentation: Guidelines for clear, unambiguous labeling and user instructions essential for safe operation and maintenance.
- Programmable electrical medical systems (PEMS): Specific considerations for software and programmable components within monitoring equipment.
- Use across patient populations: Applicability to adults, children, neonates, and fetal monitoring during labor.
Applications
IEC 60601-2-23:2011 applies to manufacturers, designers, testing laboratories, and healthcare facilities involved in:
- Development and certification of transcutaneous partial pressure monitors.
- Use of these monitors in clinical settings, including intensive care units, neonatal care, and labor and delivery wards.
- Ensuring devices meet internationally recognized safety standards for accurate monitoring of oxygen and carbon dioxide partial pressures transcutaneously.
- Supporting clinical decision-making in respiratory and metabolic monitoring by providing reliable non-invasive measurements.
- Facilitating regulatory approvals and market access by adhering to standardized technical and safety requirements.
Related Standards
- IEC 60601-1 (2005 edition) - General requirements for basic safety and essential performance of medical electrical equipment.
- Other parts of the IEC 60601 series covering specific medical electrical devices.
- Standards related to electromagnetic compatibility for medical devices.
- Guidance on alarm systems per IEC 60601-1-8 which is closely referenced for alarm functionality in transcutaneous monitors.
- International standards on risk management and software lifecycle processes relevant to programmable medical systems integrating with transcutaneous monitors.
Practical Value
Complying with IEC 60601-2-23:2011 ensures that transcutaneous partial pressure monitoring equipment is:
- Safe for use on vulnerable patient populations including neonates and fetuses.
- Correctly calibrated to provide accurate readings needed for critical clinical decisions.
- Equipped with robust alarm systems to promptly notify caregivers of hazardous conditions.
- Resistant to unintended electromagnetic interference, preventing malfunctions in clinical environments.
- Properly documented and labeled for user comprehension, facilitating safe device operation and maintenance.
Healthcare providers and manufacturers prioritizing adherence to this standard demonstrate commitment to delivering high-quality, reliable, and safe transcutaneous monitoring solutions aligned with globally recognized best practices.
Технические детали
- Технический комитет
- SC 62D - Particular medical equipment, software, and systems
- SKU
- IEC 60601-2-23:2011
Похожие стандарты
Упомянутые в описании и другие стандарты IEC
IEC TR 62348:2012
ДействующийAssessment of the impact of the most significant changes in Amendment 1 to IEC 60601-1:2005 and mapping of th…
Overview IEC TR 62348:2012 is a Technical Report from the International Electrotechnical Commission that helps users transition from IEC 60601-1:2005 (Edition 3) to the amended edition (Amendment 1:2…
IEC 60601-2-91:2026
ДействующийMedical electrical equipment - Part 2-91: Particular requirements for basic safety and essential performance…
Overview IEC 60601-2-91:2026 specifies the particular requirements for the basic safety and essential performance of non-thermal plasma wound treatment equipment and associated accessories. Developed…
IEC 62590-2-2:2026
ДействующийRailway applications - Electronic power converters for fixed installations - Part 2-2: DC Traction applicatio…
Overview IEC 62590-2-2:2026 is an international standard developed by the International Electrotechnical Commission (IEC) focusing on railway applications, specifically the electronic power converter…
IEC 61753-042-02:2026
ДействующийFibre optic interconnecting devices and passive components - Performance standard - Part 042-02: Plug-pigtail…
Overview IEC 61753-042-02:2026 establishes the minimum performance, test, and measurement requirements for plug-pigtail and plug-receptacle style OTDR (Optical Time-Domain Reflectometer) reflecting d…
IEC 61837-2:2018
ДействующийSurface mounted piezoelectric devices for frequency control and selection - Standard outlines and terminal le…
Overview IEC 61837-2:2018 - Surface mounted piezoelectric devices for frequency control and selection - Standard outlines and terminal lead connections - Part 2: Ceramic enclosures (Edition 3.0, 2018…
IEC 61851-23-1:2026
ДействующийElectric vehicle conductive charging system - Part 23-1: DC electric vehicle supply equipment - Automated con…
Overview IEC 61851-23-1:2026 is an international standard published by the International Electrotechnical Commission (IEC) that specifies requirements for DC electric vehicle supply equipment (EVSE)…
IEC 63506:2026
ДействующийCalibration of the prompt fission neutron logging tools
Overview IEC 63506:2026 - Calibration of the Prompt Fission Neutron Logging Tools is the international standard that specifies the calibration methods for prompt fission neutron (PFN) logging tools,…
IEC 63589-1:2026
ДействующийLinear accelerator - Electron linear accelerator for radiation processing - Part 1: General requirements and…
Overview IEC 63589-1:2026 specifies the general requirements and test methods for electron linear accelerator devices used in radiation processing. Developed by the International Electrotechnical Com…