IEC 60613:2010
Electrical and loading characteristics of X-ray tube assemblies for medical diagnosis
Electrical and loading characteristics of X-ray tube assemblies for medical diagnosis
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 41
- Дата публикации:
- 27 января 2010 г.
- Издание:
- IEC IS 60613 edition 3 version 1
- ICS:
- 11.040.50
IEC 60613:2010 applies to X-ray tube assemblies either with a rotating anode X-ray tube or a stationary anode X-ray tube, intended for use in medical diagnosis. For an X-ray tube head, its X-ray tube assembly aspects are also within the scope. IEC 60613:2010 covers performance-related definitions and conditions of electrical and loading characteristics of X-ray tube assemblies in relation to their behaviour during and after energization and, where appropriate, methods of presentation and measurement of these characteristics. This International Standard is therefore relevant for the manufacturer and the responsible organization. This third edition cancels and replaces the second edition of IEC 60613, published in 1989. It constitutes a technical revision. This third edition has been adapted to apply to the present technology.
Abstract
Overview
IEC 60613:2010 is an international standard issued by the International Electrotechnical Commission (IEC). It specifies the electrical and loading characteristics of X-ray tube assemblies used in medical diagnosis. The standard applies to assemblies with either rotating or stationary anode X-ray tubes, as well as the relevant characteristics of X-ray tube heads. IEC 60613:2010 defines key performance parameters, measurement conditions, and how these characteristics should be presented, supporting both manufacturers and responsible organizations in ensuring safety, performance, and compatibility.
Adopted as the third edition, this standard incorporates technological advancements in medical X-ray tube design and replaces prior editions to better serve contemporary diagnostic imaging requirements.
Key Topics
IEC 60613:2010 addresses a comprehensive range of requirements and definitions for X-ray tube assemblies, including:
-
Electrical Characteristics
- X-ray tube voltage and current (peak and mean values)
- Cathode emission characteristics and relationships with filament current
-
Loading Characteristics
- Definitions of loading time, cycle time, and loading factors
- Methods of measurement that reflect typical clinical use
-
Input Power Specifications
- Anode input power under specified operating conditions
- Nominal radiographic and CT anode input power ratings
- Continuous input power and its importance for safe operation
-
Presentation of Data
- Standardized methods for presenting ratings (tables, graphs, numerical values)
- Guidance on referencing IEC 60613:2010 for compliance
-
Terms and Definitions
- Key terms such as envelope current/voltage, CT scan power index (CTSPI), single and serial load ratings
Applications
IEC 60613:2010 is vital for a range of stakeholders and scenarios in the field of medical diagnostic imaging:
-
Manufacturers of Medical X-ray Equipment
- Provides clear criteria and standard definitions for designing and manufacturing X-ray tube assemblies and tube heads
- Facilitates accurate and standardized performance data for product labeling and documentation
-
Healthcare Facilities and Clinical Users
- Ensures selection of X-ray systems that meet defined safety and performance thresholds
- Supports preventive maintenance, performance assessments, and decision-making about equipment procurement
-
Compliance, Testing, and Quality Assurance
- Provides a basis for regulatory conformity assessment and certification
- Enables effective equipment comparison, performance verification, and routine compliance checks
-
Product Communication
- Standardized terminology assists in clear communication between suppliers, clinicians, and maintenance personnel
IEC 60613:2010 supports contemporary applications, such as advanced computed tomography (CT), general radiography, mammography, and dental imaging. Its focus on clinically relevant measurement and presentation ensures the standard aligns closely with routine diagnostic practice.
Related Standards
IEC 60613:2010 is part of a broader framework of international standards for medical electrical equipment and diagnostic imaging:
-
IEC 60601-1:2005
Medical electrical equipment - Part 1: General requirements for basic safety and essential performance -
IEC 60601-1-3:2008
Medical electrical equipment - Part 1-3: Collateral Standard: Radiation protection in diagnostic X-ray equipment -
IEC/TR 60788:2004
Medical electrical equipment – Glossary of defined terms
These related standards provide background and supporting definitions, enhance compatibility, and ensure that all essential requirements for safety, performance, and terminology are consistently addressed in medical imaging equipment.
Keywords: IEC 60613:2010, X-ray tube assembly, medical diagnostics, electrical characteristics, loading characteristics, anode input power, radiographic ratings, CT scan power index, medical imaging standards, healthcare equipment compliance, IEC standards.
Технические детали
- Технический комитет
- SC 62B - Medical imaging equipment, software, and systems
- SKU
- IEC 60613:2010
Похожие стандарты
Упомянутые в описании и другие стандарты IEC
IEC 60601-1:2005
ДействующийMedical electrical equipment - Part 1: General requirements for basic safety and essential performance
Overview IEC 60601-1:2005 (Consolidated Edition 3.1, with Amendment 1) is the international safety standard for medical electrical equipment, defining the general requirements for basic safety and es…
IEC 62590-2-2:2026
ДействующийRailway applications - Electronic power converters for fixed installations - Part 2-2: DC Traction applicatio…
Overview IEC 62590-2-2:2026 is an international standard developed by the International Electrotechnical Commission (IEC) focusing on railway applications, specifically the electronic power converter…
IEC 61753-042-02:2026
ДействующийFibre optic interconnecting devices and passive components - Performance standard - Part 042-02: Plug-pigtail…
Overview IEC 61753-042-02:2026 establishes the minimum performance, test, and measurement requirements for plug-pigtail and plug-receptacle style OTDR (Optical Time-Domain Reflectometer) reflecting d…
IEC 61837-2:2018
ДействующийSurface mounted piezoelectric devices for frequency control and selection - Standard outlines and terminal le…
Overview IEC 61837-2:2018 - Surface mounted piezoelectric devices for frequency control and selection - Standard outlines and terminal lead connections - Part 2: Ceramic enclosures (Edition 3.0, 2018…
IEC 61851-23-1:2026
ДействующийElectric vehicle conductive charging system - Part 23-1: DC electric vehicle supply equipment - Automated con…
Overview IEC 61851-23-1:2026 is an international standard published by the International Electrotechnical Commission (IEC) that specifies requirements for DC electric vehicle supply equipment (EVSE)…
IEC 63506:2026
ДействующийCalibration of the prompt fission neutron logging tools
Overview IEC 63506:2026 - Calibration of the Prompt Fission Neutron Logging Tools is the international standard that specifies the calibration methods for prompt fission neutron (PFN) logging tools,…
IEC 63589-1:2026
ДействующийLinear accelerator - Electron linear accelerator for radiation processing - Part 1: General requirements and…
Overview IEC 63589-1:2026 specifies the general requirements and test methods for electron linear accelerator devices used in radiation processing. Developed by the International Electrotechnical Com…
IEC 61837-2:2018/AMD2:2026
ДействующийAmendment 2 - Surface mounted piezoelectric devices for frequency control and selection - Standard outlines a…
Overview IEC 61837-2:2018/AMD2:2026, published by the International Electrotechnical Commission (IEC), serves as Amendment 2 to the international standard for surface mounted piezoelectric devices us…