IEC 60695-11-2:2017
Fire hazard testing - Part 11-2: Test flames - 1 kW pre-mixed flame - Apparatus, confirmatory test arrangement and guidance
Fire hazard testing - Part 11-2: Test flames - 1 kW pre-mixed flame - Apparatus, confirmatory test arrangement and guidance
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 63
- Дата публикации:
- 8 июня 2017 г.
- Издание:
- IEC IS 60695 edition 3 version 1
- ICS:
- 13.220.40
IEC 60695-11-2:2017 gives the requirements for the production and confirmation of a nominal 1 kW propane/air pre-mixed flame for use in fire hazard testing. This basic safety publication is primarily intended for use by technical committees in the preparation of standards in accordance with the principles laid down in IEC Guide 104 and ISO/IEC Guide 51. It is not intended for use by manufacturers or certification bodies. It has the status of a basic safety publication in accordance with IEC Guide 104 and ISO/IEC Guide 51. This third edition of IEC 60695-11-2 cancels and replaces the second edition published in 2013. It constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: addition of an alternative production of the test flame; deletion of Annex B. In this standard, the following print types are used: terms defined within Clause 3: in bold type. Key words: Fire Hazard, Pre-Mixed Flame, Standardized 1 kW Test Flame
Abstract
Overview - IEC 60695-11-2:2017 (1 kW pre-mixed flame)
IEC 60695-11-2:2017 is a basic safety publication from the IEC that defines the apparatus, confirmatory test arrangement and guidance for producing a nominal 1 kW propane/air pre‑mixed test flame for fire hazard testing. The third edition (2017) is a technical revision that adds an alternative flame‑production method and updates annex material. This standard is intended primarily for technical committees preparing other standards in line with IEC Guide 104 and ISO/IEC Guide 51 (it is not intended for use by manufacturers or certification bodies).
Key topics and technical requirements
- Purpose: Establish reproducible conditions for a 1 kW nominal pre‑mixed flame used as a standardized ignition source in fire hazard testing.
- Apparatus components covered:
- Burner construction and general assembly
- Gas supply and flow control for propane/air premix
- Copper block and positioning fixtures used in confirmatory checks
- Thermocouple selection and temperature/time recording instruments
- Requirements for an appropriate laboratory fumehood or chamber (draught‑free conditions)
- Production methods: Two selectable methods (Method A and Method B - B is an alternative production method added in this edition) for generating the nominal 1 kW flame.
- Confirmatory testing:
- Principle and procedures for confirming effective power output
- Frequency and practical arrangements for confirmatory checks
- Details for measurement geometry (flame dimensions, positioning), reference figures and annex guidance
- Normative references: Includes thermocouple standards (IEC 60584 series) and fire safety vocabulary (ISO/IEC 13943).
Applications and users
- Primary users: IEC technical committees and standards developers who need a consistent, reproducible 1 kW test flame definition when drafting test methods and safety requirements.
- Secondary relevance: Laboratories, research organizations and test method authors may consult this document (and companion IEC 60695 parts) to understand the standardized flame configuration and confirmatory approach when developing or harmonizing fire hazard test methods. Note: the standard itself is framed as a basic safety publication and does not provide certification procedures for manufacturers.
Related standards
- Other parts of the IEC 60695 series (e.g., 11‑3: 500 W, 11‑4: 50 W, 11‑5: needle‑flame, 11‑40: confirmatory tests guidance)
- IEC 60584 (thermocouples) and ISO/IEC 13943 (fire safety vocabulary)
Keywords: Fire Hazard, Pre‑Mixed Flame, Standardized 1 kW Test Flame, IEC 60695-11-2, test flame apparatus, confirmatory test arrangement.
Технические детали
- Технический комитет
- TC 89 - Fire hazard testing
- SKU
- IEC 60695-11-2:2017
Похожие стандарты
Стандарты, упомянутые в описании
IEC 60584-1:2013
ДействующийThermocouples - Part 1: EMF specifications and tolerances
Overview IEC 60584-1:2013 is an authoritative international standard published by the International Electrotechnical Commission (IEC), focusing on thermocouples. This standard-Part 1 of the IEC 60584…
EN IEC 60695-2-10:2026
ДействующийFire hazard testing - Part 2-10: Glowing/Hot-wire based test methods - Glow-wire apparatus and common test pr…
Overview EN IEC 60695-2-10:2026 is an international standard developed by CLC, focusing on fire hazard testing by means of glowing/hot-wire based test methods. The standard specifies the glow-wire ap…
IEC 60695-11-20:2015
ДействующийFire hazard testing - Part 11-20: Test flames - 500 W flame test method
Overview IEC 60695-11-20:2015 is a globally recognized standard from the International Electrotechnical Commission (IEC) focusing on fire hazard testing for electrotechnical products. Specifically, i…