IEC 60728-2:2018(E) applies to the radiation characteristics and immunity to electromagnetic disturbance of EM active equipment (active and passive equipment) for the reception, processing and distribution of television, sound and interactive multimedia signals as dealt with in IEC 60728-3, IEC 60728-4, IEC 60728-5 and IEC 60728-6. This document covers the following frequency ranges: - disturbance voltage injected into the mains: 150 kHz to 30 MHz; - radiation from active equipment: 5 MHz to 25 GHz; - immunity of active equipment: 150 kHz to 25 GHz; - screening effectiveness of passive equipment: 5 MHz to 3,5 GHz. This document specifies requirements for maximum allowed radiation, minimum immunity and minimum screening effectiveness and describes test methods for conformance testing. This third edition cancels and replaces the second edition published in 2010. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) Frequency extensions: a.1) The upper frequency limit of conventional cable network equipment was extended from 862 MHz to 1 000 MHz due to market demands. a.2) The first intermediate frequency range (1st IF range) for satellite signal transmission was extended to cover now frequencies from 950 MHz up to 3 500 MHz. a.3) The methods of measurement and the EMC requirements in the overlapping frequency range from 950 MHz to 1 000 MHz were allocated in relation to the upper frequency limit, 1 000 MHz, and the lower frequency limit, 950 MHz, of the relevant equipment under test. b) New EMC environment in the 800 MHz band: b.1) The European Commission has requested CENELEC and ETSI to draft immunity requirements for equipment, to protect against disturbance from the new wireless service in the 790 MHz to 862 MHz band. b.2) A CENELEC/ETSI Joint Working Group “Digital Dividend” was formed to describe the new EMC environment and to advise on appropriate test methods and limits. b.3) IEC 60728-2 is the document specifying immunity requirements for active and passive cable network equipment. b.4) The method of measurement and the requirements for in-band immunity were extended taking into account this new EMC environment due to the allocation of broadband wireless services in the frequency band 694 MHz to 862 MHz. As a consequence, the limits of in-band immunity were specified for analogue and additionally for digital signals in this frequency range. b.5) Consequently it is recommended, that, where cable networks and wireless networks coexist, only the transmission of digitally modulated signals should be used in the frequency range 694 MHz to 862 MHz. b.6) For passive equipment, Class A and Class B specifications were kept in the standard but a note was added recommending that only Class A equipment should be used in the planning and implementation of new networks. c) The methods of measurement for all kinds of indoor antennas were combined in the new 4.9. d) A Bibliography has been added at the end of the document referencing, for example, CEPT Report 30 on “The identification of common and minimal (least restrictive) technical conditions for 790-862 MHz for the digital dividend in the European Union”.
Abstract
Overview
IEC 60728-2:2018 - "Cable networks for television signals, sound signals and interactive services - Part 2: Electromagnetic compatibility for equipment" defines electromagnetic compatibility (EMC) requirements and test methods for active and passive equipment used in the reception, processing and distribution of television, audio and interactive multimedia signals. It specifies limits for radiation, immunity and screening effectiveness and describes conformance test methods across defined frequency bands. This third edition updates frequency limits, measurement methods and in‑band immunity requirements to reflect modern cable and wireless coexistence (including the digital dividend and new services in the 694–862 MHz / 790–862 MHz region).
Key topics and technical requirements
- Scope: Applies to equipment addressed in IEC 60728‑3/‑4/‑5/‑6 for cable TV, sound and interactive services.
- Frequency ranges covered:
- Disturbance voltage into mains: 150 kHz – 30 MHz
- Radiation from active equipment: 5 MHz – 25 GHz
- Immunity of active equipment: 150 kHz – 25 GHz
- Screening effectiveness of passive equipment: 5 MHz – 3.5 GHz
- Measured parameters:
- Maximum allowed radiated emissions
- Minimum immunity to external and internal electromagnetic disturbances
- Minimum screening effectiveness for passive components (splitters, connectors, coax, etc.)
- Test methods: Includes disturbance voltage measurement, absorbing clamp and substitution radiation methods, internal immunity tests, electrostatic discharge and fast transient/burst tests, and combined methods for indoor antennas.
- Significant revisions:
- Upper limit for conventional cable equipment extended to 1 000 MHz
- Satellite 1st IF range extended up to 3 500 MHz
- New in‑band immunity limits and measurement provisions to address coexistence with broadband wireless services (digital dividend) in the 694–862 MHz / 790–862 MHz bands
- Recommendation to use digitally modulated signals in 694–862 MHz where cable and wireless coexist; recommendation for Class A passive equipment in new networks
Practical applications & who uses this standard
- Equipment manufacturers (set‑top boxes, amplifiers, active nodes, outdoor/indoor units) for EMC design and compliance
- Component and passive‑device designers (connectors, splitters, coax, shielding) for screening effectiveness requirements
- Network operators and system integrators planning cable and hybrid cable/wireless networks to ensure coexistence and proper immunity
- Test laboratories and conformity assessment bodies performing EMC verification and certification
- Regulators and planners referencing EMC limits for frequency allocation and interference mitigation (digital dividend considerations)
Related standards and references
- Other parts of the series: IEC 60728‑3, ‑4, ‑5, ‑6 (network architecture, components and services)
- EMC test/criteria standards (e.g., IEC 61000 series referenced for immunity performance criteria)
- Bibliographic references such as CEPT/ETSI reports on the digital dividend and the 790–862 MHz environment
Keywords: IEC 60728-2, EMC, cable networks, television signals, screening effectiveness, radiation, immunity, measurement methods, digital dividend, 800 MHz band.
Технические детали
- Технический комитет
- TA 5 - Cable networks for television signals, sound signals and interactive services
- SKU
- IEC 60728-2:2018
Похожие стандарты
Упомянутые в описании и другие стандарты IEC
IEC 60728-3-1:2012
Cable networks for television signals, sound signals and interactive services - Part 3-1: Active wideband equ…
IEC 61000-6-2:2016
ДействующийElectromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environm…
Overview IEC 61000-6-2:2016 is the third-edition generic EMC immunity standard for industrial environments published by the IEC. It defines immunity requirements for electrical and electronic equipme…
IEC 62590-2-2:2026
ДействующийRailway applications - Electronic power converters for fixed installations - Part 2-2: DC Traction applicatio…
Overview IEC 62590-2-2:2026 is an international standard developed by the International Electrotechnical Commission (IEC) focusing on railway applications, specifically the electronic power converter…
IEC 61753-042-02:2026
ДействующийFibre optic interconnecting devices and passive components - Performance standard - Part 042-02: Plug-pigtail…
Overview IEC 61753-042-02:2026 establishes the minimum performance, test, and measurement requirements for plug-pigtail and plug-receptacle style OTDR (Optical Time-Domain Reflectometer) reflecting d…
IEC 61837-2:2018
ДействующийSurface mounted piezoelectric devices for frequency control and selection - Standard outlines and terminal le…
Overview IEC 61837-2:2018 - Surface mounted piezoelectric devices for frequency control and selection - Standard outlines and terminal lead connections - Part 2: Ceramic enclosures (Edition 3.0, 2018…
IEC 61851-23-1:2026
ДействующийElectric vehicle conductive charging system - Part 23-1: DC electric vehicle supply equipment - Automated con…
Overview IEC 61851-23-1:2026 is an international standard published by the International Electrotechnical Commission (IEC) that specifies requirements for DC electric vehicle supply equipment (EVSE)…
IEC 63506:2026
ДействующийCalibration of the prompt fission neutron logging tools
Overview IEC 63506:2026 - Calibration of the Prompt Fission Neutron Logging Tools is the international standard that specifies the calibration methods for prompt fission neutron (PFN) logging tools,…
IEC 63589-1:2026
ДействующийLinear accelerator - Electron linear accelerator for radiation processing - Part 1: General requirements and…
Overview IEC 63589-1:2026 specifies the general requirements and test methods for electron linear accelerator devices used in radiation processing. Developed by the International Electrotechnical Com…