IEC 60730-2-5:2026
Automatic electrical controls - Part 2-5: Particular requirements for automatic electrical burner control systems
Automatic electrical controls - Part 2-5: Particular requirements for automatic electrical burner control systems
- Статус документа:
- Действующий
- Формат:
- Электронный (PDF)
- Количество страниц:
- 55
- Дата публикации:
- 24 апреля 2026 г.
- Издание:
- IEC IS 60730 edition 5 version 1
- ICS:
- 97.120
IEC 60730-2-5:2026 applies to automatic electrical burner control systems for the automatic control of burners for oil, gas, coal or other combustibles intended to be used - for household and similar use; - in shops, offices, hospitals, farms and commercial and industrial applications; NOTE 1 Throughout this document, where it can be used unambiguously, the word "system" means "burner control system" and "systems" means "burner control systems". - for equipment that is used by the public, such as equipment intended to be used in shops, offices, hospitals, farms and commercial and industrial applications; NOTE 2 Throughout this document, the word "equipment" means "appliance and equipment." EXAMPLE 1 Controls for commercial catering, heating and air-conditioning equipment. - that are smart enabled controls; EXAMPLE 2 Remote interfaces/control of burner operations. - that are AC or DC powered controls with a rated voltage not exceeding 690 V AC or 600 V DC; - used in, on, or in association with equipment that use electricity, gas, oil, solid fuel, solar thermal energy, etc., or a combination thereof; - utilized as part of a control system or controls which are mechanically integral with multifunctional controls having non-electrical outputs; - using NTC or PTC thermistors and to discrete thermistors, requirements for which are contained in Annex J; - that are mechanically or electrically operated, responsive to or controlling such characteristics as temperature, pressure, passage of time, humidity, light, electrostatic effects, flow, or liquid level, current, voltage, acceleration, or combinations thereof; - as well as manual controls when such are electrically and/or mechanically integral with automatic controls. NOTE 3 Requirements for manually actuated mechanical switches not forming part of an automatic control are contained in IEC 61058-1-1. This document is applicable - to a complete burner control system; - to a separate programming unit; - to a separate electronic high-voltage ignition source; - to a separate flame detector, and - to a separate high-temperature operation (HTO) detector. - to a burner control system intended to be used in warm air heating appliances (furnaces) where the appliance is equipped with an electromechanical differential pressure control to monitor the difference of the combustion air pressure (Type 2.AL). This pressure control provides a switch as an alternative to one of the two switching elements to directly de-energize the safety relevant terminals. This document does not apply to thermoelectric flame supervision controls; thermoelectric flame supervision controls are covered by ISO 23551-6:2021. This document also applies to electrical burner control systems intended exclusively for industrial process applications e.g. those applications covered by ISO TC 244 (ISO 13577 series). This document applies to controls powered by primary or secondary batteries, requirements for which are contained within the standard. This document applies to - the inherent safety of automatic electrical burner control systems, and - functional safety of automatic electrical burner control systems, - automatic electrical burner control systems where the performance (for example the effect of EMC phenomena) of the product can impair the overall safety and performance of the controlled system, - the operating values, operating times, and operating sequences where such are associated with burner safety and to the testing of automatic electrical burner control systems used in, on, or in association with, burners. NOTE 4 Requirements for specific operating values, operating times and operating sequences are given in the standards for appliances and equipment. This document specifies the requirements for construction, operation and testing of automatic electrical burner control systems used in, on, or in association with an equipment. This document applies also to systems - incorporating
Abstract
Overview
IEC 60730-2-5:2026 is an international standard published by the International Electrotechnical Commission (IEC) that specifies the particular requirements for automatic electrical burner control systems. These systems are essential for the safe and efficient automatic control of burners using oil, gas, coal, solid fuel, or other combustibles. The standard applies to burner control systems intended for household, commercial, and industrial environments-including applications in shops, offices, hospitals, farms, and equipment accessible by the public.
This standard addresses a broad scope of burner control systems, including both smart-enabled controls and conventional systems operated electrically or mechanically. It covers devices powered by AC or DC with rated voltages up to 690 V AC or 600 V DC and is applicable to systems integrated with or associated with other equipment, such as heating and air-conditioning units.
Key Topics
IEC 60730-2-5:2026 outlines essential safety, functional, and performance requirements for automatic burner controls. Key topics include:
-
Scope and Application
- Systems for automatic control of burners in household, commercial, industrial, and public-use equipment.
- Both smart and manually actuated (integral) burner controls.
-
System Components and Requirements
- Complete burner control systems
- Separate programming units, high-voltage ignition sources, flame detectors, and high-temperature operation detectors
- Mechanically and electrically integral control systems
-
Safety and Performance
- Inherent safety measures for preventing hazardous situations
- Functional safety considerations such as response to temperature, pressure, time, humidity, and electrical parameters
- Electromagnetic compatibility (EMC), ensuring the system's performance is not impaired by EMI
-
Construction and Testing
- Requirements for materials, insulation, earthing, terminals, and mounting
- Testing procedures for electric strength, endurance, mechanical strength, resistance to environmental stress, and fire
-
Special Requirements
- Controls employing thermistors (NTC/PTC)
- Provisions for battery-powered control systems
- Exclusions for thermoelectric flame supervision controls (referenced in ISO 23551-6:2021)
Applications
IEC 60730-2-5:2026 is vital for manufacturers, designers, and maintenance professionals involved in burner control system design, production, and integration. Applications include:
-
Household Heating Systems
Ensures the safe use of programmable and automatic burner controls in furnaces and water heaters. -
Commercial and Public Equipment
Applicable to heating, catering, and air-conditioning units installed in offices, hospitals, retail spaces, and public buildings. -
Industrial Process Applications
Required for burner control systems handling complex processes and high-power systems, including those adhering to ISO TC 244 (ISO 13577 series). -
Smart and Remote Control
Supports the integration of smart-enabled systems with remote interfaces, providing users with enhanced control and monitoring functionalities. -
Safety Critical Environments
Addresses burner control systems in settings where safety and functional reliability are paramount, such as in hospitals and large-scale industrial plants.
Related Standards
For comprehensive compliance and integration, consider the following related standards:
- IEC 60730-1: General requirements for automatic electrical controls for household and similar use.
- ISO 23551-6:2021: Specific requirements for thermoelectric flame supervision controls (systems excluded from this standard).
- ISO 13577 Series: Industrial process burner controls and safety requirements.
- IEC 61058-1-1: Mechanical switch requirements not forming part of an automatic control system.
- IEC 60664-1: Insulation coordination for equipment within low-voltage systems (relevant for clearances and creepage distances).
IEC 60730-2-5:2026 plays a critical role in improving safety, reliability, and performance of automatic burner control systems, fostering compliance for manufacturers and enhanced safety for users worldwide.
Технические детали
- Технический комитет
- TC 72 - Automatic electrical controls
- SKU
- IEC 60730-2-5:2026
Похожие стандарты
Стандарты, упомянутые в описании
ISO 23551-6:2021
ДействующийSafety and control devices for gas burners and gas-burning appliances — Particular requirements — Part 6: The…
Overview ISO 23551-6:2021 specifies safety, constructional, performance and type-testing requirements for thermoelectric flame supervision controls energized by a thermocouple for use with gas burner…
BS ISO 13577-3:2016
ДействующийIndustrial furnaces and associated processing equipment. Safety. Generation and use of protective and reactiv…
IEC 60730-1:2013
ДействующийAutomatic electrical controls - Part 1: General requirements
Overview IEC 60730-1:2013 is an internationally recognized standard established by the International Electrotechnical Commission (IEC) that defines general requirements for automatic electrical contr…
IEC 61058-1-1:2016
ДействующийSwitches for appliances - Part 1-1: Requirements for mechanical switches
Overview IEC 61058-1-1:2016 is an international standard developed by the International Electrotechnical Commission (IEC) that specifies the requirements for mechanical switches used in appliances. T…
IEC 60664-1:2007
ДействующийInsulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests
Overview IEC 60664-1:2007 is an international standard published by the International Electrotechnical Commission (IEC) that defines the principles, requirements, and tests for insulation coordinatio…